Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does plunging your hand into icy water make your heart jump?
Show the answer
When you touch freezing water, nerve sensors send an emergency alert. Your nervous system triggers an automatic reflex that tightens blood vessels and shifts your blood pressure in seconds.

Introduction
Your Body's Instant Reflex Shield
Have you ever stepped into a freezing shower and gasped? Your heart pumps faster, your skin prickles, and your body tightens up instantly. You did not plan those reactions: your autonomic nervous system fired them automatically. In this experiment, you will use a Go Direct Blood Pressure Sensor to record your resting blood pressure. Then, you will test what happens when one hand is placed in icy water for fifteen seconds. You will discover how fast your body reacts to protect you.
Driving question: Why does a sudden blast of icy cold make your blood pressure jump?
What you will learn
Goals for this investigation
- I can fit a blood pressure cuff and record my baseline blood pressure.
- I can explain what systolic and diastolic blood pressure numbers mean.
- I can observe how cold water triggers a reflex that shifts blood pressure.
- I can link sudden blood pressure changes to the autonomic nervous system.
- I can explain why doctors check blood pressure as an essential vital sign.
Why it matters: Emergency doctors, cardiologists, and space medical teams monitor blood pressure to ensure blood flows smoothly to vital organs under extreme stress.
Safety first
Safety Rules for Physiology Lab
- The Go Direct Blood Pressure Sensor is an educational tool. Do not use it as a medical diagnostic device.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Do not inflate the arm cuff past 180 mmHg. Stop the pump as soon as the sensor LED blinks green.
- Never keep the cuff inflated for more than 40 seconds. Release the pressure immediately if you feel pain or if your arm tingles.
- Keep water basins and wet towels away from laptops and tablets to protect electrical devices.
- The ice bath should feel cold, not painful. Remove your hand immediately if you experience severe discomfort.
- Wipe up any water spills immediately with dry paper towels so floors remain safe and dry.
What you need
- Go Direct Blood Pressure Sensor1
- Tablet running Graphical Analysis1
- large plastic wash basin1
- ice cubes2 cups
- paper towel1 roll or small pack

Step 1 of 6
Pair sensor and configure Graphical Analysis
- Press the power button once to turn on your Go Direct Blood Pressure Sensor.
- Open Graphical Analysis on your device. Connect to the sensor over Bluetooth.
- Tap View. Select 'Graph, Table, and Meter'. Tap Mode. Change End Collection to 120 s. Tap Done.
- Tablet is securely propped away from water edges.
- The sensor power LED blinks.
- Tap Mode at the bottom left. Make sure that the duration is 120 seconds.
Careful: If you select the wrong sensor mode by accident, data collection can stop too early. Set duration to 120 seconds so you have plenty of time for smooth deflation.

Step 2 of 6
Connect the cuff hose to the sensor
- Locate the cuff hose that has a black twist connector (Luer-lock).
- Attach the twist connector to the metal stem on the sensor with a gentle quarter turn until snug.
- Hoses are straight with no sharp kinks or pinches.
- Twist connector is clean and free of dust.
- Examine the two rubber hoses on the fabric cuff. Make sure that one hose connects directly to the black bulb pump.
Careful: If you cross the threads or tighten too much, you can crack the plastic connector. Align straight and twist gently until finger-tight.

Step 3 of 6
Fit cuff onto subject's upper arm
- Wrap the cuff snugly around the subject's bare upper arm, roughly 2 cm above the elbow crease.
- Position both rubber hoses so they exit downwards over the biceps muscle and brachial artery.
- Fasten the velcro securely so you can slide just two fingertips under the cuff.
- Subject is seated quietly with feet flat on the floor.
- Clothes do not bunch up or pinch tightly above the cuff.
- The subject sits upright in a comfortable chair with their right arm on the table.
Careful: A loose cuff slips down and causes inaccurate, noisy readings. Wrap snugly 2 cm above the elbow crease so the cuff does not slide.

Step 4 of 6
Collect baseline resting blood pressure
- Tell the subject to sit still with their arm on the table. The subject must not move or speak during data collection.
- Tap Collect in Graphical Analysis. Squeeze the black bulb repeatedly to at least 160 mmHg. Stop when the sensor LED flashes green.
- Tap Stop once pressure drops below 50 mmHg and numbers calculate.
- The subject rested quietly for at least 2 minutes.
- Subject promises to stay silent and not move arm or fingers.
- The subject is relaxed, silent, and holds their arm completely still.
- The cuff will deflate automatically after you stop the pump.
Careful: Arm movement or speech during deflation causes pressure artifacts that prevent calculation. Remain silent and perfectly still until the cuff pressure falls below 50 mmHg.

Step 5 of 6
Prepare the ice water bath
- Pour about 500 mL of room temperature or cool water into the plastic wash basin.
- Add 1 to 2 cups of ice cubes and stir gently until the water feels intensely cold.
- Place the ice basin on the subject's left side next to the uncuffed hand, with a dry towel ready.
- Basin is placed at least 30 cm away from the computer or tablet.
- A towel is right beside the basin.
- Leave the blood pressure cuff in place on the subject's arm.
Careful: Do not splash cold water onto electronics or the floor. Pour water carefully. Keep ice water well away from electronic gear.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 11, Biology, chapter 15: Body Fluids and Circulation
- Related Class 11, Biology, chapter 16: Excretory Products and Their Elimination
- Related Class 10, Biology, chapter 11: Endocrine System
- Direct Level AS & A Level, Biology, chapter 8: Transport in mammals
- Direct Level DP, Biology, chapter B3.2: Transport
- Direct Level DP, Biology, chapter D3.3: Homeostasis
Versions and what each needs
- How does cold change your blood pressure? (Human Physiology Vol 2)
Human Physiology Vol 2, 50 min, Based on a Vernier lab
Needs: Go Direct Blood Pressure Sensor - How does cold change your blood pressure? (Advanced Biology)
Advanced Biology, 50 min, Based on a Vernier lab
Needs: Go Direct Blood Pressure Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.