Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

A steaming mug sitting on a table next to a stop clock showing time passing

Wonder

How can a cooling liquid tell detectives when an event happened?

Show the answer

Warm objects cool down following a strict mathematical rule. By measuring how fast an evidence sample loses heat, investigators can calculate the exact timeline.

A warm ceramic mug of tea on a wooden table with faint steam rising

Introduction

How Does Cooling Tell the Time?

Imagine investigators arrive at an empty room and find a warm mug of tea. The liquid is 35°C, but fresh tea is brewed near 90°C. Can they find out when the cup was made? Yes! Everything cools following a reliable mathematical pattern. In this lab, you will model cooling using warm water and a digital probe to uncover how heat loss reveals the passage of time.

Driving question: Can the way a warm object cools down reveal exactly when an event took place?

What you will learn

Today you will find out

  • I can record temperature data over time using a temperature probe.
  • I can explain how the speed of cooling changes over time.
  • I can use a curve fit to describe cooling data.
  • I can trace points on a curve to find how much time has passed.
  • I can give examples of real jobs that rely on cooling rates.

Why it matters: Forensic scientists, food safety inspectors, and thermal engineers all use cooling curves to track time and prevent hazards.

Safety first

Scientist Rules for Today

  • Wear safety goggles, lab aprons, and nitrile gloves throughout the lab.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Warm water at 50°C can startle you if it splashes. Pour carefully with a graduated cylinder.
  • Keep tablets and electronic cables at least 30 cm away from water beakers.
  • Never taste any lab liquid. Do not touch the probe to your skin during the test.
  • Report any spilled water immediately and dry it with paper towels.
  • Wash your hands with soap and water after you complete cleanup.

What you need

  • Go Direct Temperature Probe1
  • Tablet running Graphical Analysis1
  • ring stand with clamp1
  • Test tubes and rack1 tube and 1 rack
  • 25 mL graduated cylinder1
  • 100 mL beaker with warm water (50°C)approx. 40 mL
  • paper towelseveral sheets
  • Splash goggles and nitrile gloves1 set per student
Notebook showing evidence record table filled with case details

Step 1 of 8

Record the evidence report data

  1. In your forensic case notes, record the evidence temperature: 26°C.
  2. Record the time of the temperature measurement: 9:45 PM.
  3. You will use this information later to calculate the timeline.
Stop and check
  • Your workspace is clean and uncluttered.
  • Safety goggles and gloves are on.

Careful: If you mix up case values, your final timeline calculation becomes incorrect. Write down 26°C and 9:45 PM clearly in your evidence table.

Tablet screen displaying time-based data collection settings set to 20 minutes

Step 2 of 8

Connect probe and configure settings

  1. Turn on the Go Direct Temperature Probe. Connect it in Graphical Analysis with Bluetooth.
  2. Tap Mode. Change Time Units to min, Rate to 20 samples/min, and End Collection to 20 min.
  3. Tap Done to lock in the settings.
Stop and check
  • Tablet battery has at least 30% charge.
  • The sensor LED blinks green when paired.

Careful: If you leave units in seconds, data collection stops too early. Confirm the horizontal axis displays 'Time (min)' and ends at 20 min.

Student hand holding temperature probe in the air away from surfaces

Step 3 of 8

Measure ambient room temperature

  1. Hold the probe upright in the air by its plastic handle.
  2. Watch the live reading on the tablet until the number stays steady for 15 seconds.
  3. Record this room temperature in your evidence record.
Stop and check
  • The probe metal shaft is completely dry and clean.
  • Your hands touch only the teal plastic handle.
  • Do not touch the metal shaft with your fingers, and keep it away from sunny windows or drafts.

Careful: If you touch the metal shaft, body heat warms it and causes a false room temperature. Grip only the plastic handle and hold the probe steady in still room air.

Ring stand holding temperature probe vertically over a test tube in a rack

Step 4 of 8

Assemble the stand and test tube

  1. Place the test tube rack on the table. Insert your clean test tube.
  2. Attach the three-prong utility clamp at mid-height on the ring stand next to the rack.
  3. Clamp the upper plastic handle of the temperature probe so the probe points straight down.
Stop and check
  • The ring stand base is stable and rests flat on the table.
  • The clamp screw is snug and does not wobble.

Careful: If you over-tighten the metal clamp on glass, you can crack the tube. Clamp the plastic probe handle securely above the tube. Make sure that the tube stands safely in the rack.

Student pouring warm water from graduated cylinder into test tube with probe centered

Step 5 of 8

Measure and pour 20 mL of warm water

  1. Use the 25 mL graduated cylinder to measure exactly 20 mL of the 50°C water.
  2. Carefully pour the 20 mL of warm water into the test tube first.
  3. Lower the clamped probe into the water. Make sure that the tip sits centered in the liquid and does not touch the glass.
Stop and check
  • Water temperature from teacher supply is about 50°C.
  • Gloves and goggles are on.
  • Make sure the metal probe does not touch the glass sides or bottom of the tube.

Careful: Splashes of warm water can startle you. If the probe tip touches glass, it measures glass temperature instead of water. Pour smoothly at eye level. Center the probe tip in the liquid so it does not touch glass.

3 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 11, Physics, chapter 3: Thermal Properties of Matter

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.