Experiments › Physics
How does electric current flow?
Measure Electric Current
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does adding a measuring meter sometimes turn off a glowing bulb?
Show the answer
A current meter is like a super-fast highway lane. Connect it the wrong way and all electricity skips your bulb entirely! Today you will master the secret to measuring current accurately.

Introduction
The Mystery of the Current Detective
When you turn on a torch, electric charges flow through the wires and light bulb in an unbroken loop. This flow of charge is called electric current. But how can we measure this invisible flow? If you tap into wires the wrong way, the bulb goes pitch black and the meter reads crazy numbers! Today, you become an electrical detective to discover the exact way to measure electric current.
Driving question: How do you measure electric current without messing up the circuit?
What you will learn
Your Goals Today
- I can explain why an ammeter must be connected in series inside the loop.
- I can observe what happens when a meter bypasses a bulb.
- I can conclude that an ammeter provides an easy low-resistance path for electric current.
- I can build a multi-bulb circuit and measure electric current safely.
- I can relate circuit paths and short circuits to real-world home electrical safety.
Why it matters: Electricians, robotics engineers, and electronics designers measure current daily to keep gadgets and homes safe from electrical fires.
Safety first
Lab Rules for Electrical Experiments
- Wear safety goggles throughout the experiment.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Only use low-voltage dry cells (3 V) or teacher-approved power sources. Never connect to wall outlets.
- Disconnect the battery clip whenever you change circuit wires to avoid accidental short circuits.
- If a wire or battery feels warm to the touch, disconnect the battery immediately and tell your teacher.
- Keep water and liquids far away from all electrical equipment and tablets.
- Wash your hands with soap after you touch circuit wires and components.
What you need
- Go Direct Current Probe1
- Tablet running Graphical Analysis1
- miniature light bulb with base socket3 identical
- dry cell battery2 D-cells in holder (3 V)
- electrical wire with alligator clips6 wires
- safety goggles1 per person

Step 1 of 6
Pair and zero the Current Probe
- Press the power button on the Go Direct Current Probe.
- Open Graphical Analysis on your tablet. Connect the probe with Bluetooth.
- Keep probe leads disconnected from any circuit. Tap Zero in the app.
- Tablet Bluetooth is enabled.
- Probe clip leads do not touch any metal or batteries.
- Probe battery LED blinks green.
- The meter should read 0.000 A.
Careful: If you zero the probe while it connects to a live circuit, you create an offset error. Make sure that the probe leads are completely free in the air when you set zero.

Step 2 of 6
Assemble the 3-bulb base circuit
- Line up your 3 bulbs: Test Bulb, Bulb #1, and Bulb #2.
- Use alligator clip wires to connect them in a single series loop with the 3 V battery pack.
- Observe all 3 bulbs glow with equal, gentle brightness.
- Battery voltage is 3.0 V (two 1.5 V D-cells).
- Alligator clips grip bulb terminals firmly.
- No loose clips touch each other.
- This complete loop matches Figure 1 from your manual.
Careful: A loose alligator clip causes lights to flicker or breaks circuit loops. Pinch clips firmly onto the metal terminal screws of the socket bases.

Step 3 of 6
Include probe as the Test Current Probe
- Disconnect the wire between the battery and the Test Bulb.
- Connect the Go Direct Current Probe right there in line with the circuit.
- Read and record this baseline series current in amperes.
- You unclip the circuit before you insert the probe.
- The probe sits in line and completes the loop.
- The tablet displays live current.
- Current now flows from the battery, through the probe, and through the 3 bulbs.
Careful: If you reverse the leads, the screen shows a negative current reading. If the current reads negative, simply swap the red and black clips.

Step 4 of 6
Test the across connection (Figure 2A)
- Take two extra wire leads from your second meter (or jumper wire).
- Clip one lead to the left terminal of Bulb #1 and the other to its right terminal.
- Observe what happens to Bulb #1, the Test Bulb, and the current reading!
- Do not touch the Test Equipment section on the left.
- Connect only across Bulb #1.
- Watch the brightness of all three bulbs.
- The Test Current Probe measures the main circuit.
Careful: If you short out too many components, excessive current warms the wires. Connect across Bulb #1 for only a few seconds to record observations, then unclip.

Step 5 of 6
Discover the correct series connection
- Remove the bypass wires from Bulb #1 so all 3 bulbs light up again.
- Disconnect the wire that connects Bulb #1 to Bulb #2.
- Insert your ammeter into this gap so current flows through Bulb #1, through the meter, and into Bulb #2.
- Disconnect the battery before you change the bulb connection.
- Insert meter between Bulb #1 and Bulb #2.
- Reconnect battery once connections are secure.
- Observe all 3 bulbs: none go dark and current does not change!
Careful: An open circuit leaves all bulbs unlit if you do not complete the loop. Make sure that the meter bridges the gap between the two bulbs completely.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 6, Science, chapter 1: The Wonderful World of Science
- Direct Class 7, Science, chapter 3: Electricity: Circuits and their Components
- Direct Class 11, Physics, chapter 1: Units and Measurement
- Direct Class 7, Physics, chapter 17: Electric Circuit and Its Components
- Related Level AS & A Level, Physics, chapter 9: Electricity
Versions and what each needs
- How does electric current flow?
Physics Explorations, 45 min, Based on a Vernier lab
Needs: Go Direct Current Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.