Experiments › Biology

How does your body stop acid spikes?

Investigating Buffers

Grades 7-8Biology1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 5 steps. To run it with the sensors, record data and take the quiz, students use the app.

A tall clear glass of iced lemonade with a lemon slice next to a freshly cut lemon half on a wooden kitchen table

Wonder

Why doesn't drinking sour lemon juice turn your blood into acid?

Show the answer

Your blood stays locked near pH 7.4 every second you are alive. Special chemical shock absorbers called buffers grab extra acid or base particles instantly. Today you will test a natural buffer in action!

A glass of lemon juice and a glass of water on a table

Introduction

How Does Your Body Stop Acid Spikes?

When you drink a fizzy cola or eat sour curd, you swallow strong acids. Yet the pH of your blood barely budges from 7.4. If your blood pH changed by even half a unit, your cells would stop working! How does your body protect itself? It uses chemical shields called buffers. In this lab, you will add strong acid and strong base to a baking soda solution to discover how buffers defend their pH.

Driving question: Why doesn't drinking acidic orange juice change the pH of your blood?

What you will learn

Today you will find out

  • I can explain what a buffer does when acid or base enters a liquid.
  • I can use and rinse a pH sensor safely to record steady pH numbers.
  • I can observe and record how baking soda resists both acid and base.
  • I can calculate total pH change and explain why living bodies need buffers.
  • I can give examples of buffers working in medicine and nature.

Why it matters: Buffers protect your bloodstream, keep swimming pools safe, and stop acid rain from poisoning mountain lakes.

Safety first

Lab Safety Rules for Buffers

  • Wear splash goggles, protective gloves, and a lab apron at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • 0.10 M hydrochloric acid (HCl) causes skin and eye damage. An adult dispenses all acid drops.
  • 0.10 M sodium hydroxide (NaOH) causes skin and eye irritation. An adult dispenses all base drops.
  • The glass bulb at the tip of the pH sensor is thin and fragile. Never touch it against the beaker glass.
  • If any chemical touches your skin, rinse it under tap water immediately for 15 minutes.
  • Never taste or drink any liquid in the laboratory.

What you need

  • Go Direct pH Sensor1
  • Ring stand with clamp1
  • Tablet running Graphical Analysis1
  • 50 mL beaker2
  • 25 mL graduated cylinder1
  • 1% baking soda solution60 mL
  • 0.1 M Hydrochloric acid solution10 mL in dropper bottle · teacher
  • 0.10 M Sodium hydroxide solution10 mL in dropper bottle · teacher
  • Distilled water wash bottle1
  • 250 mL beaker2 (one for parking probe, one waste)
  • Plastic Beral pipets2 · teacher
  • Splash goggles and nitrile gloves1 set per person
Student hands clamping the Go Direct pH Sensor into the utility clamp on a ring stand

Step 1 of 5

Clamp and park the pH sensor

  1. Unscrew the storage bottle cap and gently slide the bottle off the electrode.
  2. Clamp the sensor shaft into the utility clamp on the ring stand.
  3. Put the probe tip in a 250 mL beaker with 100 mL of tap water.
Stop and check
  • The ring stand base rests flat and sturdy on the bench.
  • Storage bottle is set upright in a safe spot so storage liquid does not spill.
  • Do not over-tighten the utility clamp on the plastic sensor shaft.
  • The Go Direct pH Sensor is powered on and paired over Bluetooth in Graphical Analysis.

Careful: The glass bulb at the electrode tip breaks if dropped or hit against metal. Support the sensor with two hands while you tighten the clamp gently.

Student rinsing the clamped pH sensor with a distilled water wash bottle into a waste beaker

Step 2 of 5

Prepare the baking soda solution

  1. Measure exactly 20 mL of 1% sodium bicarbonate solution with a 25 mL graduated cylinder.
  2. Pour the 20 mL into a clean 50 mL beaker.
  3. Lift the pH sensor from tap water. Fully rinse its tip with distilled water over the waste beaker.
Stop and check
  • The 50 mL beaker is clean and dry.
  • Graduated cylinder reading is measured at eye level at the bottom of the meniscus.
  • Rinse water is directed into the waste beaker.
  • Do not wipe the glass bulb with rough paper: gently touch a lint-free tissue to droplets on the plastic body.

Careful: Scratches or dryness on the glass bulb damage the sensor membrane. Only rinse with distilled water. Never scrub or rub the glass tip.

Student gently swirling the beaker around the clamped pH sensor while tablet shows steady reading

Step 3 of 5

Immerse sensor and record 0 drops

  1. Gently swirl the beaker by hand around the stationary sensor.
  2. Tap Collect in Graphical Analysis.
  3. When the pH reading is stable, tap Keep. Type '0'. Tap Keep Point.
Stop and check
  • The sensor bulb is fully submerged in the liquid.
  • The tip does not touch the glass bottom or side of the beaker.
  • The beaker is swirled gently so no liquid splashes out.
  • The 50 mL beaker of sodium bicarbonate rests under the sensor with the bulb submerged about 15 mm into the liquid.

Careful: If the glass bulb hits the bottom of the beaker, the glass can crack. Keep the clamp adjusted so the sensor hangs at least 5 mm above the beaker floor.

Adult in purple gloves adding acid drops while student in blue gloves swirls the beaker

Step 4 of 5 Teacher does this

Add acid in 5-drop batches

  1. Have the adult add 5 drops of 0.10 M HCl to the sodium bicarbonate with the acid pipet. Swirl for 5 seconds.
  2. When the pH reading stabilizes, tap Keep, type '5', and tap Keep Point.
  3. Repeat in 5-drop steps (10, 15, 20, 25, 30 drops). Tap Stop after 30 drops in Graphical Analysis.
Stop and check
  • Everyone has goggles and gloves on.
  • Only the adult holds and dispenses from the 0.10 M HCl bottle.
  • The dropper tip never touches the sensor glass or beaker edge.

Careful: 0.10 M HCl can irritate skin and cause eye damage if splashed. Adult: dispense drops slowly just above the liquid surface. Swirl gently so the liquid does not splash.

Adult in purple gloves adding drops of sodium hydroxide base into a fresh beaker of baking soda

Step 5 of 5 Teacher does this

Test fresh baking soda with base

  1. Measure 20 mL of FRESH 1% sodium bicarbonate solution into a second clean 50 mL beaker.
  2. Rinse the pH sensor tip thoroughly with distilled water over the waste beaker, lower it in, and start a new data set in Graphical Analysis.
  3. Record 0 drops, then the adult adds 0.10 M NaOH base in 5-drop batches up to 30 drops, swirling and keeping each point.
Stop and check
  • Waste liquid is emptied into the waste beaker, not down the drain yet.
  • Acid residues do not contaminate the new trial because you fully rinsed the sensor tip.
  • Only the adult handles the 0.10 M NaOH dropper.
  • The waste beaker holds the acid-tested sodium bicarbonate.
  • You fully rinse the pH sensor with distilled water into the waste container.

Careful: 0.10 M NaOH can cause skin irritation and is caustic to eyes. Adult dispenses base drops carefully. Rinse any splashes with plenty of cold water.

0 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

Cambridge AS & A Level
  • Related Level AS & A Level, Biology, chapter 3: Enzymes
  • Related Level AS & A Level, Biology, chapter P1: Practical skills for AS Level

Versions and what each needs

  • How does your body stop acid spikes?
    Investigating Biology, 50 min, Based on a Vernier lab
    Needs: Go Direct pH Sensor

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.