Experiments › Physics
How efficient is a wind turbine?
Turbine Efficiency
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can a wind turbine ever catch all the energy blowing in the breeze?
Show the answer
No matter how high-tech the blades are, moving air must escape behind them so fresh air can enter. Today you measure the limit yourself.

Introduction
Can We Catch 100% of the Wind?
Giant wind turbines catch breezes across hills and oceans to power entire towns. You might think the perfect turbine converts every bit of moving air into electricity. But if a turbine stopped 100% of the wind, the air would freeze solid in front of the blades! Air has to keep moving past so new air can push through. Today you will test a model turbine, change blade angles, and discover the exact science of turbine efficiency.
Driving question: Why can even the world's best wind turbine never capture all the energy in the wind?
What you will learn
Your Mission Today
- I can measure wind turbine electrical power output accurately.
- I can measure wind speed right in front of turbine blades.
- I can explain why moving air cannot be completely stopped by turbine blades.
- I can find the best blade pitch angle from my power and wind data.
Why it matters: Engineers shape wind turbine blades down to fractions of a degree. Even a 2% boost in efficiency powers thousands more homes every year.
Safety first
Lab Rules for Spinning Turbines
- Wear safety goggles at all times while the fan or turbine turns.
- Never stand directly in the plane of the turbine blades as they turn.
- Keep hands, hair, clothes, and sensor cords far away from blades that turn.
- Turn off the electric fan completely before you touch or adjust blade angles.
- Purple gloves = teacher does it. Blue gloves = you do it.
What you need
- Go Direct Energy Sensor1
- Go Direct Weather System1
- Vernier Variable Load1
- KidWind wind experiment kit1 assembled turbine with 3 blades
- electric desk fan1 3-speed fan
- protractor1 Blade Pitch Protractor
- ruler1 metric ruler
- electrical wire with alligator clips2 jumper wires with clips
- safety goggles1 pair per student

Step 1 of 6
Set Blade Pitch with the Protractor
- Loosen the hub knob slightly so the three blades can twist.
- Use your Blade Pitch Protractor to set each blade to exactly 10 degrees.
- Tighten the hub knob firmly so the blades cannot slip while they turn.
- Fan is completely off.
- Blades are securely wedged in the 12-hole hub.
- Safety goggles are on.
- Make sure the fan is turned off and unplugged.
Careful: A loose blade can fly out when it turns fast. Tighten the hub face knob securely by hand before every test run.

Step 2 of 6
Wire the Energy Sensor and Variable Load
- Set the switch on the Energy Sensor to External Load.
- Plug the red and black generator wires of the turbine into 'Source'. Connect 'External Load' to the Variable Load with jumper wires.
- Turn the dial on the Variable Load until it reads about 35 ohms.
- All alligator clips grip bare metal terminals tightly.
- Wires do not cross into the path of blades that turn.
- Energy sensor switch is set to External Load.
- Slide the switch on the Go Direct Energy Sensor to 'External Load'.
Careful: Wires that catch in blades that turn can pull sensors off the table. Route all cables along the tabletop away from the rotor circle.

Step 3 of 6
Align the Fan, Weather Sensor, and Turbine
- Place the box fan so it faces the wind turbine directly.
- Set the distance between the fan face and turbine hub to exactly 45 cm.
- Mount the Go Direct Weather System on a ring stand between the fan and turbine.
- Turbine tripod base rests firmly on the table.
- The fan rests stable on its base.
- Clear away loose papers that could blow around.
- Use a ruler to make sure the center of the fan aligns with the turbine hub.
- Keep this distance and weather sensor spot exactly the same for all trials!
Careful: The turbine falls over when the fan blows at full speed. Tape the turbine legs down or press lightly on the base if needed.

Step 4 of 6
Run Polarity Check and Fan Test
- Turn the fan to HIGH and watch the turbine spin up.
- Look at the live Power reading on your tablet meter.
- If Power is negative or zero, turn off the fan and swap the two wires at the Source terminals.
- Everyone in the group wears goggles.
- Clear of the blade rotation plane.
- Hands away from blades.
- Put on your safety goggles and make sure no one is in the blade rotation plane.
Careful: Blades that turn can strike fingers if you reach around the fan while it runs. Keep all hands behind the fan or at the tablet while the rotor turns.

Step 5 of 6
Record Data for 10-Degree Pitch
- Turn on the fan to HIGH. Wait 30 seconds for a steady speed.
- Click 'Collect' in Graphical Analysis to record 30 seconds of data.
- Tap Graph Tools 'View Statistics' to record Mean Power and Mean Wind Speed.
- Fan speed is steady.
- Weather sensor is undisturbed in its bracket.
- Blades turn smoothly and do not wobble.
- Turn off the fan after data collection.
Careful: If you stop data collection before readings stabilize, you get inaccurate averages. Wait 30 seconds while the blades turn before you click Collect.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Level DP, Physics, chapter 3: A.3 Work, energy and power
Versions and what each needs
- How efficient is a wind turbine?
Renewable Energy, 50 min, Based on a Vernier lab
Needs: Go Direct Energy Sensor, Go Direct Weather (sensor only)
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.