Experiments › Biology

How fast can living things multiply?

Population Dynamics

Grades 7-8Biology2 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

A ceramic bowl on a kitchen table overflowing with puffed yeast dough

Wonder

What happens when a living crowd outgrows its home?

Show the answer

A few cells can multiply into millions when they have plenty of food, but numbers crash when food runs out. Scientists call this population dynamics, and today you will track how a population booms and busts.

Two test tubes showing clear juice turning milky as yeast multiplies

Introduction

The Rise and Fall of a Yeast City

Imagine a tiny city trapped inside a glass test tube. At first, the few living cells have plenty of food, warmth, and room to grow. They divide rapidly, doubling their numbers again and again. Soon the clear liquid turns milky with millions of swimming bodies. But what happens when the food is eaten and waste piles up? In this experiment, you will watch a living population boom, peak, and crash using both a light-measuring sensor and a microscope.

Driving question: What happens when a population runs out of food and space?

What you will learn

Today you will discover

  • I can explain how a closed population booms, peaks, and declines.
  • I can measure liquid cloudiness using a spectrophotometer.
  • I can count yeast cells properly under a microscope.
  • I can explain why light readings stay higher than living cell counts when cells die.
  • I can connect yeast growth limits to wildlife populations and food making.

Why it matters: Wildlife ecologists track animal herds, doctors monitor bacteria in infections, and bakers cultivate yeast for bread using these exact population rules.

Safety first

Lab Rules for Microbiology

  • Wear safety goggles, nitrile gloves, and a lab apron throughout the experiment.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Never taste or drink the yeast culture or apple juice broth in the laboratory.
  • Glass microscope slides and coverslips are extremely thin and can cut skin if pressed too hard.
  • Keep all test tubes and liquids at least 30 cm away from the SpectroVis sensor and tablet.
  • Wash your hands fully with soap and warm water when you finish each day.

What you need

  • Go Direct SpectroVis Plus Spectrophotometer1 per station
  • Plastic cuvette (4 clear sides)1 per group
  • compound light microscope1 per group
  • microscope slide and cover slip2 slides, 4 coverslips
  • two 18 × 150 mm test tubes2 per group
  • two 5 mL pipettes2 per group
  • Beral pipet1 per group
  • distilled water100 mL wash bottle
  • lint-free tissue1 box per station
  • safety goggles1 per student
Gloved student hand wiping a clear cuvette with a lint-free tissue

Step 1 of 9

Prepare a distilled water blank cuvette

  1. Fill a clean, dry cuvette 3/4 full with distilled water.
  2. Press the cap firmly onto the cuvette top.
  3. Wipe the clear outside windows gently with a lint-free wipe to remove water spots.
Stop and check
  • Wear safety goggles and gloves.
  • Hands are dry and cuvette is free of scratches.
  • Handle the cuvette only by the top rim of its ribbed sides.

Careful: Fingerprints or grease on clear sides block light and distort calibration. Pinch only the top ribbed edges; use a clean lint-free wipe.

Inserting the cuvette into Go Direct SpectroVis Plus with tablet display

Step 2 of 9

Connect and calibrate the SpectroVis Plus

  1. Connect to the sensor with Bluetooth or a USB cable.
  2. Select 'Absorbance vs. Concentration' from the experiment chooser.
  3. Slide the water blank into the cuvette slot and tap 'Finish Calibration'.
Stop and check
  • The sensor power LED glows green.
  • The cuvette clear sides face the internal light beam path.
  • The Go Direct SpectroVis Plus is turned on and Spectral Analysis is open.

Careful: If you calibrate before the internal lamp warms up, readings drift. If the app shows a warm-up countdown, wait for it to finish. Then tap Finish Calibration.

Tablet screen showing 600 nm selected in Spectral Analysis

Step 3 of 9

Set the measuring wavelength to 600 nm

  1. Leave the blank cuvette in the spectrophotometer.
  2. Tap the wavelength box. Enter 600 nm.
  3. Tap Done to lock in 600 nm for your daily tests.
Stop and check
  • App shows 600 nm locked in.
  • The sensor remains still on a flat table.

Careful: A different wavelength gives numbers that do not match class averages. Make sure that you select 600 nm before you leave the screen.

Two test tubes labelled E and C in a rack

Step 4 of 9

Collect your Day 0 broth samples

  1. Receive two labelled 18 x 150 mm test tubes from your teacher.
  2. Place both tubes upright in your test tube rack.
Stop and check
  • Tubes are held securely in a rack.
  • Labels E and C are clearly written.
  • Tube E contains 2.5 mL of Experimental broth inoculated with yeast.
  • Tube C contains 2.5 mL of sterile Control broth with no yeast.

Careful: If you swap tube caps or labels, you mix the control and live yeast cultures. Keep tubes in separate slots; never mix up the caps or pipettes.

Student dispensing 2.5 mL distilled water from a pipette into a test tube

Step 5 of 9

Dilute both tubes by half with distilled water

  1. Use a clean 5 mL pipette to add 2.5 mL of distilled water into Tube E.
  2. Use a second clean pipette to add 2.5 mL of distilled water into Tube C.
  3. Gently swirl both tubes so each contains 5.0 mL of 1:2 diluted liquid.
Stop and check
  • Use clean pipette for water to prevent cross-contamination.
  • Read the pipette liquid meniscus at eye level.
  • When you add 2.5 mL of water, you cut the culture strength by 50%.

Careful: Unequal water volumes change the dilution ratio and ruin comparisons. Carefully align the bottom of the water curve with the 2.5 mL mark.

4 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Direct Class 8, Science, chapter 2: The Invisible Living World: Beyond Our Naked Eye
  • Direct Class 10, Science, chapter 7: How do Organisms Reproduce?
  • Direct Class 11, Biology, chapter 2: Biological Classification
  • Related Class 11, Biology, chapter 10: Cell Cycle and Cell Division
  • Direct Class 12, Biology, chapter 5: Molecular Basis of Inheritance
  • Direct Class 12, Biology, chapter 9: Biotechnology : Principles and Processes
  • Direct Class 12, Biology, chapter 11: Organisms and Populations
ICSE (CISCE)
  • Related Class 10, Biology, chapter 13: Population and Related Problems in India
Cambridge AS & A Level
  • Direct Level AS & A Level, Biology, chapter 1: Cell structure
  • Direct Level AS & A Level, Biology, chapter 5: The mitotic cell cycle
  • Related Level AS & A Level, Biology, chapter 10: Infectious disease
  • Related Level AS & A Level, Biology, chapter 17: Selection and evolution
IB Diploma
  • Direct Level DP, Biology, chapter C41.1: Populations and communities

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.