Experiments › Chemistry
How fast does gas build up?
Reaction Rates
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 10 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does hydrogen peroxide foam up on a cut but sit quietly in a bottle?
Show the answer
Hydrogen peroxide breaks down naturally into oxygen and water, but very slowly. Add a helper chemical, and oxygen rushes out in seconds! Today you trap that gas to measure exact reaction speed.

Introduction
Catching Gas Under Pressure
Some chemical changes take centuries, like iron rusting underground. Others take a split second, like fireworks popping. How do chemists time a reaction? When a reaction makes a gas, we can trap it in a closed space. As more gas bubbles form, the air pressure climbs. By watching how fast the pressure rises on a live graph, we measure the reaction speed with high precision.
Driving question: How can measuring trapped gas show us how fast a chemical reaction is happening?
What you will learn
Your Goals for Today
- I can explain how a catalyst speeds up a reaction.
- I can track rising gas pressure as new gas forms.
- I can find reaction speed from the slope of a line.
- I can seal glassware properly and run the reaction safely.
- I can name real-life situations where reaction speed matters.
Why it matters: Engineers speed up reactions to make life-saving medicines and slow down reactions to keep food fresh. Learning to measure reaction speed is the first step.
Safety first
Laboratory Rules for Pressure Experiments
- Wear safety goggles, nitrile gloves, and a lab coat at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Hydrogen peroxide irritates skin and eyes. Flush any accidental splash with water immediately.
- Never exceed 130 kPa of pressure. If pressure gets near 130 kPa, pull the stopper off right away.
- Keep your face away from the mouth of the flask when you insert or remove the stopper.
- Wash your hands fully with soap and water after you clean up.
What you need
- Go Direct Gas Pressure Sensor1
- Go Direct Temperature Probe1
- Stir Station1
- 125 mL Erlenmeyer flask1
- Two-hole rubber stopper with valve and tubing1 set
- 10 mL graduated cylinders2
- 50 mL graduated cylinder1
- 3% hydrogen peroxide, H2O2, solution15 mL · teacher
- 0.5 M potassium iodide, KI, solution10 mL
- Distilled water wash bottle1
- magnetic stir bar1
- utility clamp1

Step 1 of 10
Power on and pair your sensors
- Turn on the Go Direct Gas Pressure Sensor and Go Direct Temperature Probe.
- Open Graphical Analysis on your tablet or computer.
- Connect both sensors with Bluetooth.
- Table surface is dry and free of clutter.
- Bluetooth is enabled on your tablet or computer.
- Check that live readings appear on the screen.
Careful: Sensors may connect to another team's device in a busy room. Match the small sensor ID printed on the back label with the name in the app.

Step 2 of 10 Teacher does this
Add water and peroxide to the flask
- Use the 50 mL graduated cylinder to measure 45 mL of distilled water. Pour it into the 125 mL Erlenmeyer flask.
- An adult measures 10 mL of 3% hydrogen peroxide and pours it into the flask.
- Carefully slide the magnetic stir bar down the tilted inside wall of the flask.
- Everyone wears splash goggles and gloves.
- The Erlenmeyer flask has no cracks or chips.
- Measure 45 mL of distilled water with the 50 mL graduated cylinder.
Careful: Splashing hydrogen peroxide can cause stinging and skin whitening. The adult pours the peroxide slowly. Slide the stir bar gently so glass does not break.

Step 3 of 10
Mount flask and test stirrer speed
- Place the flask onto the Vernier Stir Station platform.
- Clamp the flask neck securely with the utility clamp or Electrode Support.
- Turn the stirrer knob to a medium slow setting (around mark 5).
- The clamp holds the flask neck snugly and does not crush the glass.
- Flask sits flat on the centre of the Stir Station.
- Make sure that the stir bar spins smoothly and does not splash liquid up the walls.
Careful: Stir speeds that are too fast create strong foam and splash into the stopper holes. Set the knob to medium slow (setting 5) so the liquid swirls smoothly and does not splash.

Step 4 of 10
Record the starting temperature
- Lower the metal tip of the Temperature Probe into the liquid mix.
- Wait 15 seconds until the temperature reading stays steady.
- Write down the temperature, then remove the probe and wipe it dry.
- The stirrer is paused so the probe tip does not strike the stir bar.
- Clean tissue is ready to wipe the probe.
- Turn off the stirrer for a moment.
Careful: If you leave the probe inside the flask, it blocks the rubber stopper. Take the reading, remove the probe completely, and set it safely on the table.

Step 5 of 10
Connect tubing to the pressure sensor
- Connect one end of the clear plastic tube to the rubber stopper connector.
- Connect the other end to the white valve port on the Gas Pressure Sensor.
- Turn each Luer-lock connector half a turn until snug. Do not overtighten.
- The tube has no kinks, bends, or twists.
- The blue stopcock valve is turned perpendicular to its stem to close it.
- Confirm that the blue handle on the second stopper port is closed (crosswise).
Careful: If you twist plastic Luer connectors too much, you can snap the small threads. Turn only half a turn until snug. Never force the plastic connector.
5 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Level AS & A Level, Chemistry, chapter 7: Redox reactions
- Related Level AS & A Level, Chemistry, chapter 8: Equilibria
- Related Level AS & A Level, Chemistry, chapter 10: Periodicity
- Related Level AS & A Level, Chemistry, chapter 11: Group 2
- Related Level AS & A Level, Chemistry, chapter P1: Practical skills 1
- Related Level AS & A Level, Chemistry, chapter P2: Practical skills 2
Versions and what each needs
- How fast does gas build up?
Chemistry through Inquiry, 50 min, Based on a Vernier lab
Needs: Go Direct Gas Pressure Sensor, Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.