Experiments › Chemistry

How fast does nail polish remover react?

Ethyl Acetate

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

A bottle of nail polish remover and a cotton pad on a wooden table beside a bottle of nail polish

Wonder

How fast does nail polish remover react?

Show the answer

Tiny charged particles in water slow down as the liquid reacts. Scientists call this reaction rate, and today you will clock it.

A bottle of nail polish remover and cotton pads resting on a wooden dressing table

Introduction

Tracking an Invisible Chemical Reaction

Nail polish remover contains a sweet-smelling chemical called ethyl acetate. When it mixes with another clear liquid, sodium hydroxide, a chemical reaction takes place right away. Both liquids look just like water, with no colour change and no bubbles! How can you tell how fast they are reacting? Electricity is the secret. As the reaction happens, the liquid becomes worse at carrying electric current. By measuring this drop in electrical conductivity, you can track the speed of the reaction second by second.

Driving question: How can we measure the speed of an invisible chemical reaction using electricity?

What you will learn

Today you will discover

  • I can explain why ions in water let electricity flow.
  • I can watch conductivity decrease as a chemical reaction takes place.
  • I can determine which chemical makes the reaction speed up more when added in larger amounts.
  • I can safely run a sensor and magnetic stirrer during a chemistry trial.
  • I can name everyday jobs that track chemical reactions using conductivity.

Why it matters: Soap factories, perfume makers, and water treatment plants all use electrical conductivity to tell exactly when chemical reactions are finished.

Safety first

Lab Safety Rules

  • Wear chemical splash goggles, lab apron and nitrile gloves at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Sodium hydroxide can irritate skin and eyes. Flush immediately with tap water if touched.
  • Ethyl acetate is flammable and produces strong vapours. Keep it away from heat. Keep it away from open flames.
  • Do not pour ethyl acetate onto the Stir Station plastic case. Clean spills immediately.
  • Do not taste or smell chemicals directly. Work in a well-ventilated classroom.

What you need

  • Go Direct Conductivity Probe1 per group
  • Stir Station1 per group
  • Electrode Support1 per group
  • magnetic stir bar1 per group
  • 100 mL beakers2 per group
  • 10 mL graduated cylinders1 per group
  • 50 mL graduated cylinder2 per group
  • Tablet running Graphical Analysis1 per group
  • 0.10 M Sodium hydroxide solution100 mL (diluted to 0.010 M)
  • clear solution in a reagent bottle15 mL 0.10 M ethyl acetate
  • Distilled water wash bottle1 wash bottle
  • Splash goggles and nitrile gloves1 set per student
Conductivity probe resting in standard solution inside a beaker

Step 1 of 9

Condition the conductivity probe

  1. Pour about 40 mL of conductivity standard solution into a 150 mL beaker.
  2. Lower the tip of the Platinum-Cell Conductivity Probe into the standard solution.
  3. Let the probe soak for at least 5 minutes before your first trial.
  4. This primes the sensitive platinum electrode plates for accurate readings.
Stop and check
  • Splash goggles and gloves are on.
  • Beaker is stable on the flat bench.
  • Standard solution is at room temperature.

Careful: If you drop the probe into the beaker, you can crack the glass beaker. Lower the probe gently into the liquid and rest it upright.

Electrode support clamped to Stir Station holding conductivity probe above beaker

Step 2 of 9

Assemble the Stir Station and probe clamp

  1. Place the Stir Station on your table. Insert its vertical support rod.
  2. Attach the Electrode Support clamp to the rod.
  3. Remove the probe from the standard soak. Rinse the tip with distilled water. Snap the probe into the Electrode Support clamp.
  4. Place a clean 100 mL reaction beaker onto the round platform of the Stir Station.
Stop and check
  • Stir Station is turned OFF at the power switch.
  • Support rod is screwed tightly into the Stir Station base.

Careful: A loose clamp can let the probe slide down and strike the bottom of the beaker. Tighten the clamp thumbscrew firmly with your fingers.

Student pouring sodium hydroxide solution from a graduated cylinder into a 100 mL beaker

Step 3 of 9

Prepare Trial 1 base mixture

  1. Use a clean 50 mL graduated cylinder to measure 20.0 mL of 0.010 M NaOH solution.
  2. Use a second 50 mL cylinder to measure 28.0 mL of distilled water.
  3. Pour both into the 100 mL reaction beaker on the Stir Station.
  4. Carefully place the magnetic stir bar into the beaker. Do not drop it in forcefully.
Stop and check
  • You wear splash goggles and gloves.
  • Reading cylinder marks at eye level at the bottom of the meniscus.
  • Spill paper towels are nearby.

Careful: Dilute sodium hydroxide causes burns and irritation if it splashes into eyes or on skin. Pour slowly down the inside wall of the beaker. Wipe any dribble on the beaker lip immediately.

Stir Station spinning a small vortex in beaker with conductivity probe positioned safely to side

Step 4 of 9

Position probe and start gentle stirring

  1. Lower the Conductivity Probe into the beaker until the liquid covers the slot near the tip.
  2. Make sure the probe tip is off to the side. Keep the tip safely above the path of the stir bar.
  3. Turn the Stir Station knob to setting 5 or 6 (moderate stir speed with a tiny vortex).
  4. Record the initial live conductivity reading (about 980 µS/cm) in your table before you add other chemicals.
Stop and check
  • The stir bar does not hit the probe tip when it turns.
  • The probe slot is fully under liquid.
  • Liquid does not splash out of the beaker.

Careful: If the magnetic bar hits the probe tip, it can damage the electrode or splash liquid. Position the probe near the side wall of the beaker. Start stirrer slowly and increase to speed 5.

Student pouring 2.0 mL ethyl acetate into spinning beaker while tablet graphs falling curve

Step 5 of 9

Launch Trial 1 and add ethyl acetate

  1. Carefully measure exactly 2.0 mL of 0.10 M ethyl acetate in the 10 mL graduated cylinder.
  2. Tap Collect in Graphical Analysis on your tablet to start data collection.
  3. Immediately pour the 2.0 mL of ethyl acetate into the solution as it stirs.
  4. Watch the graph trace the curve live for the full 180 seconds (3 minutes).
Stop and check
  • 2.0 mL ethyl acetate measured precisely.
  • One team member ready to tap Collect, one ready to pour.
  • Keep bottle capped to reduce vapours.

Careful: Ethyl acetate vapour is flammable and irritates your lungs. If you pour too fast, the liquid can splash. Pour smoothly into the centre vortex. Do not put your face directly over the beaker.

4 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 12, Chemistry, chapter 3: Chemical Kinetics
Cambridge AS & A Level
  • Related Level AS & A Level, Chemistry, chapter 9: Rates of reaction
  • Related Level AS & A Level, Chemistry, chapter 16: Halogenoalkanes
  • Direct Level AS & A Level, Chemistry, chapter 17: Alcohols, esters and carboxylic acids
  • Related Level AS & A Level, Chemistry, chapter 22: Reaction kinetics
  • Related Level AS & A Level, Chemistry, chapter 27: Organic nitrogen compounds
  • Related Level AS & A Level, Chemistry, chapter 28: Polymerisation
  • Related Level AS & A Level, Chemistry, chapter 29: Organic synthesis