Experiments › Chemistry

How fast does purple dye vanish?

Rate Crystal Violet

Grades 7-8Chemistry2 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 4 of its 4 steps. To run it with the sensors, record data and take the quiz, students use the app.

A white cotton kitchen towel with a bright purple berry stain fading clean into spotless white cloth

Wonder

Can a bright purple stain vanish right before your eyes?

Show the answer

When tiny particles bump together, they join into a new colourless substance. Scientists call this a chemical reaction, and today you will time how fast it happens.

A white cotton cloth showing a bright purple dye stain fading until it is completely clear

Introduction

The Disappearing Purple Trick

Some chemical changes happen in a flash, like fireworks exploding. Others take weeks, like an iron nail rusting in the rain. Today, you will explore a reaction that takes just a few minutes. Crystal violet is an intense purple dye. When mixed with sodium hydroxide, it slowly loses all its colour. How fast does this fading happen? Today, you will track the speed of this chemical reaction as the purple liquid turns completely clear.

Driving question: Why do some colours fade away, and how can we measure the exact speed of a disappearing dye?

What you will learn

Goals for this investigation

  • I can explain why the purple colour fades during the chemical reaction.
  • I can calibrate and use a colorimeter to record colour changes over time.
  • I can read a reaction graph to see how fast dye disappears.
  • I can explain how particle collisions affect reaction speed.
  • I can connect reaction rates to real-life chemical processes.

Why it matters: From food preservation and medicines working in your body to stain removers in laundry, controlling reaction speed is essential in science.

Safety first

Laboratory Safety Rules

  • Wear splash goggles, protective gloves, and a lab apron at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Sodium hydroxide solution can irritate your skin and eyes. Avoid all contact.
  • Crystal violet dye causes intense purple stains on skin, clothes, and tables.
  • If any chemical splashes on your skin, rinse immediately with cold tap water.
  • Never taste or drink any liquid in the science laboratory.
  • Keep all chemical liquids at least 30 cm away from tablets and sensors.

What you need

  • Go Direct Colorimeter1 per group
  • Go Direct Temperature Probe1 per group
  • Plastic cuvette (4 clear sides)2 per group
  • Crystal violet solution (2.5 x 10^-5 M)10.0 mL per group
  • 0.10 M Sodium hydroxide solution10.0 mL per group
  • 10 mL graduated cylinders2 per group
  • 100 mL beakers2 per group
  • glass stirring rod1 per group
  • Distilled water wash bottle1 per group
  • Lint-free tissue box1 box per station
  • Tablet running Graphical Analysis1 per group
Two graduated cylinders on a lab bench, one holding purple dye and one holding clear liquid

Step 1 of 4 Teacher does this

Measure the reaction liquids

  1. Put on your safety goggles and protective gloves.
  2. Use one 10 mL cylinder to measure exactly 10.0 mL of crystal violet dye.
  3. Use your second 10 mL cylinder to measure exactly 10.0 mL of 0.10 M NaOH.
Stop and check
  • Goggles and gloves are securely worn by everyone.
  • Each cylinder has a clear label to avoid an early mix.
  • Any drips are cleaned immediately with damp paper towel.
  • Keep each liquid in its own cylinder until you are fully ready to react.

Careful: An accidental early mix starts the reaction before the sensor is ready. Splashes irritate skin. Pour slowly at eye level. Keep the cylinders flat on the bench.

A student placing a clean water cuvette into the Go Direct Colorimeter chamber

Step 2 of 4

Calibrate the colorimeter with water

  1. Fill a clean cuvette three-quarters full with pure distilled water.
  2. Place the cuvette into the colorimeter slot with clear sides along the light path.
  3. Press the arrow buttons to set the wavelength to 565 nm (Green) and press CAL with the lid closed.
Stop and check
  • Handle the cuvette only by its ribbed, frosted top edges.
  • Check that the outside surfaces are completely dry and smudge-free.
  • Wipe the outside walls dry with a lint-free tissue.
  • Set wavelength to 565 nm (Green).
  • When the indicator light is steady, calibration is complete.

Careful: Fingerprints or droplets on clear sides scatter light and distort calibration. Wipe fully with a lint-free tissue. Examine the cuvette under good light.

Two hands pouring purple dye and clear liquid together into a glass beaker

Step 3 of 4 Teacher does this

Mix liquids and load the cuvette

  1. Pour both 10.0 mL cylinders simultaneously into a clean 100 mL beaker.
  2. Stir once with the glass stir rod to mix fully.
  3. Fill the cuvette three-quarters full. Put it into the colorimeter.
Stop and check
  • Colorimeter is calibrated, empty, and ready.
  • Graphical Analysis is open to the empty graph screen.
  • Teammates have assigned roles: pourer, cuvette loader, and timer.
  • Work smoothly and quickly as a team.
  • Empty your water cuvette and rinse it twice with 1 mL portions of the reaction mix.
  • Wipe the sides and close the colorimeter lid immediately.

Careful: If you take too long to transfer the mix, you lose the first part of the reaction data. Pour, stir, rinse, and load within 20 to 30 seconds. Do not rush.

A tablet plotting a downward curved line as colorimeter logs data beside it

Step 4 of 4

Record the fading colour for 200 seconds

  1. Tap 'Collect' in Graphical Analysis right as you shut the colorimeter lid.
  2. Watch the graph plot one absorbance reading every second.
  3. Observe how the live absorbance reading drops continuously over time.
Stop and check
  • Colorimeter lid remains securely closed.
  • Waste beaker is placed safely away from tablets.
  • Keep the colorimeter lid closed. Do not bump the bench during data collection.
  • Data collection stops automatically after 200 seconds.

Careful: If you open the colorimeter lid, stray room light floods the sensor. This causes large spikes on the graph. Leave the lid closed until collection finishes completely.

0 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Direct Class 12, Chemistry, chapter 3: Chemical Kinetics
IB Diploma
  • Direct Level DP, Chemistry, chapter Reactivity 2.2: How fast? The rate of chemical change

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.