Experiments › Chemistry

How fast does yeast eat sugar?

Sugar Fermentation

Grades 7-8Chemistry2 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

A loaf of freshly baked crusty bread cut open showing airy bubble pockets inside

Wonder

How do tiny baker's yeast cells blow thousands of bubbles in bread dough?

Show the answer

Yeast cells feast on sugar and release carbon dioxide gas without oxygen. Today you trap that gas and measure the rising pressure.

A glass mixing bowl of raw bread dough expanding and rising with trapped gas bubbles

Introduction

Why Does Bread Dough Rise?

When a baker mixes yeast, flour, water, and sugar, the dough slowly puffs up. Yeast is a tiny living fungus that eats sugar for energy. Deep inside dense dough, there is no fresh oxygen. The yeast ferments sugar anaerobically, making alcohol and carbon dioxide gas bubbles. Today, you trap those gas bubbles inside a sealed test tube and use a gas pressure sensor to measure how fast the pressure rises.

Driving question: How fast does living yeast turn sugar into gas when air is shut out?

What you will learn

Today you will find out

  • I can explain how yeast makes gas from sugar without air.
  • I can measure gas pressure rising over time.
  • I can find how fast gas forms from the slope of my graph.
  • I can keep a warm water bath at the best temperature for yeast.
  • I can use an oil layer to keep oxygen away from yeast.

Why it matters: Bakers, bio-fuel makers, and food scientists all track fermentation rates to control yeast reactions precisely.

Safety first

Scientist Rules for Today

  • Wear safety goggles, lab aprons, and nitrile gloves at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Warm water baths must not exceed 45 degrees Celsius to prevent scalds.
  • Never taste the glucose solution or yeast mixture. Never eat from lab glassware.
  • If the pressure reaches 130 kPa, disconnect the plastic tube immediately so the stopper does not pop off.
  • Clamp glassware securely. Do not overtighten the clamp, or the test tube can crack.
  • Wash your hands with soap and water after you touch yeast and lab equipment.

What you need

  • Go Direct Gas Pressure Sensor1 per group
  • Go Direct Temperature Probe1 per group
  • Stir Station1 per group
  • Electrode Support1 per group
  • 1 L beaker1 per group
  • 18 × 150 mm test tube1 per group
  • 1-hole rubber stopper assembly1 assembly with plastic tubing w/Luer-lock fitting
  • utility clamp1 per group
  • 10 mL graduated cylinder1 per group
  • yeast suspension15 mL per group
  • 5% glucose solution15 mL per group
  • vegetable oil in a dropper bottle1 dropper bottle per group
  • basting bulb1 per group
  • Tablet running Graphical Analysis1 per group
Student setting up 1 L beaker water bath with temperature probe on Stir Station

Step 1 of 6

Set up the warm water bath

  1. Pour warm and cool water into the 1 L beaker until it holds 800 to 900 mL.
  2. Use the Electrode Support to lower the Go Direct Temperature Probe into the water.
  3. Adjust with warm or cool water until the reading stays between 38 and 40 °C.
Stop and check
  • Water does not boil and is not hotter than 45 °C.
  • The beaker sits flat and steady on the Stir Station.
  • Sensor cables stay away from water.
  • Place the beaker onto the Stir Station.

Careful: Hot water can scald skin if it splashes when you pour it into a large beaker. Pour water gently into the centre of the beaker. Keep hands clear of hot rims.

Student pouring 2 mL of yeast suspension into test tube containing glucose

Step 2 of 6

Add glucose and yeast to the tube

  1. Use the 10 mL cylinder to measure 2.0 mL of 5% glucose solution. Pour the solution into the test tube.
  2. Measure 2.0 mL of yeast suspension. Add it to the test tube.
  3. Gently flick the tube to mix the yeast and glucose together.
Stop and check
  • Test tube is clean and dry.
  • Rinse the graduated cylinder before you measure yeast.
  • Goggles and gloves are on.
  • Gently swirl the yeast suspension so settled yeast mixes evenly.

Careful: If a glass test tube falls on the bench, it can shatter. Keep the test tube upright in a rack when you do not hold it.

Student adding vegetable oil drops to form a protective layer over yeast mixture

Step 3 of 6

Seal with a vegetable oil layer

  1. Hold the dropper bottle of vegetable oil close to the liquid surface.
  2. Add vegetable oil drop by drop until it forms a complete layer over the mixture.
Stop and check
  • Dropper tip is inside the tube but does not touch the liquid.
  • Top 5 cm of the test tube glass remains clean and dry.
  • Do not let oil run down the inside walls near the top of the tube.

Careful: Oil smeared near the rim of the tube can make the rubber stopper slip out. Direct oil drops straight onto the liquid surface in the center.

Student twisting stopper into test tube and securing it with utility clamp in water bath

Step 4 of 6

Insert stopper and clamp in bath

  1. Insert the 1-hole rubber stopper firmly into the test tube with a slight twist.
  2. Use the utility clamp to secure the test tube inside the 1 L beaker water bath.
  3. Leave the plastic tube disconnected from the stopper connector during incubation.
Stop and check
  • Stopper is twisted firmly for an airtight seal.
  • Rubber stopper stays above the water level.
  • Clamp screws are snug and do not crush the glass.
  • Make sure most of the tube is submerged in water, but the stopper stays well above the waterline.
  • Make sure that the clamp holds the tube firmly without excess force.

Careful: You can crush the glass test tube if you overtighten the metal clamp screw. Turn clamp thumbscrew until the tube cannot wiggle; do not force it further.

Water bath with clamped tube during 10-minute incubation, tablet showing timer and 39 °C

Step 5 of 6

Incubate for 10 minutes

  1. Leave the tube in the water bath undisturbed for 10 minutes.
  2. Keep the water bath between 38 and 40 °C.
  3. If you add warm or cool water, first use the bulb to remove an equal amount of water. This prevents beaker overflow.
Stop and check
  • The bulb is ready for water adjustments.
  • The timer runs for 10 minutes.
  • Waste beaker is nearby to hold removed water.
  • If the bath cools, use the bulb to take out 50 mL. Replace it with warm water.
  • Check the temperature probe reading on your tablet every 2 minutes.

Careful: Water overflows the 1 L beaker if you add warm water before you remove cold water. Always remove water with the bulb before you add hot water.

1 more step, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Direct Class 12, Chemistry, chapter 2: Alcohols, Phenols and Ethers
ICSE (CISCE)
  • Related Class 7, Biology, chapter 4: Respiration
  • Direct Class 8, Biology, chapter 8: Food Production
  • Related Class 9, Biology, chapter 7: Respiration in Plants
  • Direct Class 9, Biology, chapter 9: Economic Importance of Bacteria and Fungi
IB Diploma
  • Direct Level DP, Biology, chapter B4.2: Ecological niches
  • Direct Level DP, Biology, chapter C1.2: Cell respiration

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.