Experiments › Human Physiology
How fast does your pulse travel?
Pulse Transit Time
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
When your heart beats, does your arm feel the pulse at the exact same instant?
Show the answer
Every heartbeat fires an electrical spark that squeezes blood outward. That squeeze creates a ripple wave down your arteries. Today you will clock the exact split second that pulse wave takes to reach your arm.

Introduction
The Speed of a Heartbeat Ripple
When you drop a pebble into a calm pond, ripples take time to reach the edge. Your circulatory system works in a very similar way! When your heart muscle squeezes, it launches a physical wave of pressure through your blood vessels. By tracking both the electrical start signal at your heart and the physical push in your arm, you can measure the speed of your own pulse wave.
Driving question: How long does it take for a wave of blood to travel from your heart to your arm?
What you will learn
Today you will find out
- I can explain what causes the sharp R peak in a heartbeat recording.
- I can record an EKG and arm pulse wave at the same time.
- I can find the time gap between the heart's electrical squeeze and the pulse in the arm.
- I can explain why pulse waves take longer to reach more distant body parts.
- I can describe how doctors use pulse wave speed to evaluate blood vessel health.
Why it matters: Stiff or clogged blood vessels carry waves faster than soft, elastic vessels. Doctors track pulse wave speeds to test heart health without surgery.
Safety first
Lab Rules for Human Physiology
- Wear light blue student gloves during electrode preparation. Wear them during clean-up.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Use this equipment only for education. Do not use these sensors to diagnose health conditions.
- Never inflate the blood pressure cuff past 180 mmHg or leave it pumped up for more than 1 minute.
- If the subject feels numbness, a tingle sensation, or discomfort, open the silver valve immediately to release air.
- Do not pull or yank lead wires; peel electrode patches gently from skin when finished.
What you need
- Go Direct EKG Sensor1
- Go Direct Blood Pressure Sensor1
- Electrode tabs (consumable)3 tabs per volunteer
- Tablet running Graphical Analysis1
- tissue wipes1 pack

Step 1 of 8
Connect sensors in Graphical Analysis
- Switch on both Go Direct sensors. Start Graphical Analysis.
- Connect both the EKG Sensor and Blood Pressure Sensor with Bluetooth.
- In Sensor Channels for Blood Pressure, turn OFF Cuff Pressure and turn ON Oscillations.
- Both sensors are charged.
- App is open and ready to pair.
- Leave EKG Sensor channels on their normal settings.
Careful: Wrong channels selected will show a giant pressure slope instead of the pulse wiggles. Make sure that you select 'Oscillations' for the Blood Pressure sensor.

Step 2 of 8
Set up a two-graph display
- In Graphical Analysis, tap View and choose 2 Graphs.
- Set the top graph to EKG vs Time and bottom graph to Oscillations vs Time.
- Tap Mode. Set Rate to 100 samples/s and End Collection to 40 s.
- Both graphs are visible on screen.
- Rate is set to 100 samples/s.
Careful: If you sample too slowly, you will miss the sharp EKG spike completely. Make sure that the collection rate is 100 samples per second.

Step 3 of 8
Prep skin and stick electrode tabs
- Wipe the volunteer's inner forearms and wrists with a damp tissue. Dry the skin fully.
- Stick patch 1 on the inside of the RIGHT wrist.
- Stick patch 2 on the inside of the RIGHT forearm and patch 3 on the inside of the LEFT forearm, both below the elbow.
- Skin is clean and completely dry.
- Tabs are stuck firmly with no lifted edges.
- Pick one group member to be the volunteer.
Careful: Oily skin causes loose tabs. Loose tabs create fuzzy electrical noise in the data. Press each adhesive tab firmly on clean skin.

Step 4 of 8
Snap on color-coded EKG leads
- Connect the BLACK clip to the tab on the RIGHT wrist (ground).
- Connect the GREEN clip to the tab on the RIGHT forearm (negative).
- Connect the RED clip to the tab on the LEFT forearm (positive).
- Black is on the right wrist.
- Green is on the right forearm.
- Red is on the left forearm.
- Lay the wires gently on the table so they do not pull on the skin.
Careful: If you swap the red and green clips, your EKG graph will flip upside down. Double check colors: Red goes to the left arm.

Step 5 of 8
Wrap blood pressure cuff on left arm
- Place the cuff around the volunteer's LEFT upper arm, 2 cm above the elbow.
- Wrap the cuff snugly with the velcro, but not uncomfortably tight.
- Have the volunteer rest their arm completely relaxed and flat on the table.
- Cuff is 2 cm above the elbow fold.
- Hoses sit over the front of the inner arm (brachial artery).
- Volunteer can slide one finger easily under the edge.
- Check the two rubber hoses: they must point forward over the inner bicep.
Careful: Hoses positioned behind or under the arm will miss the artery pulse vibrations. Position the hoses so they point forward over the biceps muscle.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 10, Biology, chapter 8: The Circulatory System
- Direct Level DP, Biology, chapter B3.2: Transport
Versions and what each needs
- How fast does your pulse travel?
Human Physiology Vol 2, 60 min, Based on a Vernier lab
Needs: Go Direct Blood Pressure Sensor, Go Direct EKG Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.