Experiments › Chemistry
How fresh is your peroxide?
Peroxide
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The complete lab is below, free, in View mode.
The complete lab, free
Free complete lab for CBSE Class 11 Chemistry Alpha: being verified by teachersEvery screen of the lab as it appears in the Stemious app's View mode: all 8 steps, the data, observations, conclusions and quiz. Quiz answers stay in the app, so the quiz still works in class. To run it with the sensors and save each student's data, use the app.

Wonder
Why does an old bottle of peroxide stop fizzing on cuts?
Show the answer
Hydrogen peroxide slowly turns into plain water over time. Today you will measure its true chemical strength using an electron sensor and a purple testing liquid.

Introduction
How Fresh Is Your Peroxide?
When you pour fresh hydrogen peroxide on a scrape, it bubbles instantly into oxygen gas and water. But if the bottle sits in the cabinet for a year, it gets weak. Inside the bottle, the peroxide slowly breaks down on its own. How can you tell if an old bottle is still good? In this lab, your teacher will drip a bright purple testing liquid into diluted peroxide. You will use an ORP sensor to catch the exact moment every peroxide molecule has reacted.
Driving question: How can we find the exact strength of medicine-cabinet peroxide using an electron sensor?
What you will learn
Today you will find out
- I can explain how a voltage jump shows that a reaction is finished.
- I can describe the colour change that happens during the reaction.
- I can find the turning point on a graph of voltage versus volume.
- I can follow safety rules when observing and recording data.
- I can give examples of why testing chemical strength matters in daily life.
Why it matters: Pharmacists, water treatment engineers, and paper makers test chemical strengths every day so products work safely.

Try These
Testing Water in City Plants
- Drinking water plants add chlorine or ozone to kill harmful bacteria.
- Engineers use ORP sensors to measure the water's chemical punch and ensure it is safe to drink.

Try These
Checking Medicine Expiry Dates
- Liquid medicines lose their strength as molecules slowly break apart over months.
- Quality control chemists use titration to verify that every bottle on pharmacy shelves meets safety standards.

Try These
Bleaching Paper Pulp Naturally
- Paper factories use hydrogen peroxide to bleach wood pulp bright white without harsh chlorine.
- Workers constantly test the peroxide concentration to use just enough and protect nearby rivers.
Warm-up question
What happens to hydrogen peroxide as a bottle sits open for many months?
- It slowly turns into water and oxygen gas
- It turns into strong acid
- It becomes more concentrated and dangerous
- Nothing changes at all
Warm-up question
What does an ORP sensor measure in a liquid mix?
- The electrical push from electrons being traded
- How hot or cold the liquid is
- How cloudy the liquid looks
- The total weight of the beaker

Key idea
Chemicals trade electrons during reactions
- Some chemical reactions involve trading tiny negative particles called electrons.
- Permanganate grabs electrons greedily from hydrogen peroxide.
- As long as peroxide is present, permanganate loses its purple colour instantly.
- When all peroxide is gone, the reaction stops.
Everyday example: Batteries run flashlights because chemicals inside trade electrons to push electricity through wires.

Key idea
The sudden jump at the turning point
- An ORP sensor acts like a tiny voltmeter in the liquid.
- During the reaction, the electrical push stays fairly flat near 650 millivolts.
- The instant the last peroxide particle reacts, the next drop of permanganate has nothing to react with.
- This causes an immediate, steep jump in voltage up to over 1000 millivolts.
Everyday example: Like a seesaw: you can push down slowly, but once you cross the balance point, it snaps up suddenly.
Words to know: Turning point, ORP Sensor
Safety first
Laboratory Rules for Titration
- Wear safety goggles, lab aprons, and nitrile gloves at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Sulfuric acid (4.5 M) is highly corrosive. It causes severe burns. Only the teacher measures and dispenses acid.
- Potassium permanganate stains skin and clothes permanently and oxidises organic materials.
- Look for the ADULT NEEDED badge. Your teacher must do those steps.
- Keep tablets and sensor cables 30 cm away from all liquids on the bench.
- Report any spill to your teacher immediately. Never touch liquid spills with bare hands.
What you need
- Go Direct ORP Sensor1
- Stir Station1
- Electrode Support1
- 50 mL buret1
- 250 mL beaker1
- magnetic stir bar1
- Distilled water wash bottle1
- 0.020 M potassium permanganate solution35 mL
- 4.5 M sulfuric acid solution10 mL
- Dilute hydrogen peroxide solution10 mL
- Tablet running Graphical Analysis1

Step 1 of 8 Teacher does this
Prepare the reaction beaker
- Measure 10.0 mL of dilute hydrogen peroxide into a 250 mL beaker.
- Add 25 mL of distilled water.
- Carefully measure and add 10 mL of 4.5 M sulfuric acid.
- Teacher wears goggles, lab apron, and purple gloves.
- Students wear goggles and stand one pace back.
- The teacher caps the acid bottle immediately after measurement.
- Notice that the mixture remains completely clear and colourless.
Careful: Sulfuric acid generates heat when mixed and causes severe burns if splashed. Only the teacher dispenses the acid. Pour acid slowly down the side of the beaker.

Step 2 of 8
Set up the Stir Station
- Place the 250 mL beaker on the centre of the Stir Station platform.
- Carefully slide the white magnetic stir bar into the beaker.
- Turn the Stir Station dial so the bar spins smoothly and does not splash.
- Gloves and goggles on.
- Beaker sits flat on the Stir Station ring.
- The Stir Station dial points to zero before you plug it in.
- Switch on the Stir Station light to illuminate the liquid from below.
Careful: If you drop the stir bar hard, you can crack the beaker bottom. Tilt the beaker gently and let the stir bar slide down the glass wall.

Step 3 of 8 Teacher does this
Fill the buret
- Attach the buret clamp and 50 mL buret to the stand.
- Place a waste cup beneath the buret. Rinse the buret with purple permanganate.
- Fill the buret above the 0.0 mL mark with 0.020 M permanganate.
- Buret stopcock is closed (horizontal) before you pour.
- Small plastic funnel is seated in top of buret.
- You pour below eye level to prevent face splashes.
- Drain a few drops so the tip is completely filled with liquid and free of bubbles.
Careful: Potassium permanganate spills stain tables and skin brown-purple. Pour through a small funnel slowly; wipe any drips with a damp paper towel.

Step 4 of 8
Position the ORP sensor
- Slide the Go Direct ORP sensor into the Electrode Support clamp.
- Rinse the sensor tip fully with distilled water over a waste cup.
- Lower the sensor into the 250 mL beaker until the liquid covers the red tip.
- Storage bottle unscrewed and set safely aside.
- Distilled water rinse completed.
- Stir bar spins steadily before you lower the probe.
- Make sure that the sensor does not touch the stir bar or the buret tip.
Careful: The stir bar can strike the fragile platinum glass tip and break it. Position the probe near the side wall of the beaker, at least 1 cm above the stir bar.

Set up the sensor
Configure Graphical Analysis for Titration
- Sensor
- Go Direct ORP Sensor
- App
- Vernier Graphical Analysis
- Why this mode
- You record one voltage point for each millilitre of purple liquid added from the buret.
- Before you start
- Factory calibration stored in sensor is accurate. No calibration required.

Predict
As purple liquid is added drop by drop, what do you predict the graph will look like?
Think about our key ideas: the reaction keeps trading electrons until the peroxide runs out.
- The voltage will stay steady, then suddenly jump up high when the peroxide is used up
- The voltage will climb in a perfectly straight diagonal line from start to finish
- The voltage will drop down to zero immediately upon the first drop
- The voltage will bounce wildly up and down without any pattern
Students record a prediction in the app before collecting data.

Step 5 of 8
Record the starting point (0 mL)
- Tap Collect on the tablet to start data collection.
- Before you open the buret, wait for the voltage number to become steady.
- Tap Keep. Type 0 for Volume (mL). Tap Keep Point.
- Stir bar spins steadily.
- Buret stopcock is completely closed.
- Live voltage reading is stable on screen.
- Make sure that the first dot is at zero millilitres on your graph.
Careful: If you type the wrong volume number, you create an incorrect first data point. Always make sure that you enter 0 before any liquid drops from the buret.

Step 6 of 8 Teacher does this
Add permanganate in 1 mL steps
- Carefully open the stopcock to add 1.0 mL of purple liquid.
- Wait 5 seconds until the millivolt reading stabilizes.
- Read the exact buret level, tap Keep, and type the volume.
- Adult operates the buret stopcock.
- Student watches the buret scale at eye level.
- Stir bar continues to spin smoothly.
- Notice that the purple drop turns completely colourless almost immediately in the liquid.
Careful: If you open the stopcock too wide, you add too much liquid at once. Turn the stopcock handle slowly to control the flow drop by drop.

Step 7 of 8 Teacher does this
Approach the turning point drop by drop
- Slow down: add permanganate drop by drop now.
- Watch for a single drop that leaves a persistent faint pink blush in the beaker.
- At this exact moment, the voltage shoots upward by hundreds of millivolts!
- Stir speed is brisk so each drop mixes instantly.
- Student watches the tablet screen closely.
- Teacher adds one drop at a time.
- Around 18 mL, notice the purple colour takes a few seconds longer to fade.
Careful: If you add liquid too fast, you will miss the exact millilitre value of the vertical jump. Add one drop. Wait for the voltage to settle. Record the data. Add the next drop.

Step 8 of 8
Complete the curve and stop
- Add 2 to 3 more millilitres after the jump to establish the upper flat line.
- Tap Stop on the tablet screen to end data collection.
- Close the buret stopcock completely. Turn off the Stir Station.
- Buret stopcock is completely closed.
- Stir Station dial is turned back to 0.
- Data collection has been stopped.
- The voltage will level off between 1150 and 1200 millivolts.
Careful: If you leave the buret valve open, the beaker will overflow onto the bench. Double check that the stopcock handle is in the horizontal (closed) position.
Read your graph
Finding the Turning Point
- The line stays almost flat from 0 mL to about 19 mL.
- Between 19.5 mL and 20.5 mL, the voltage climbs steeply like a cliff.
- The middle of that steep vertical jump is the turning point: approximately 20.1 mL.
- This volume tells us how much peroxide was originally in the sample.
Troubleshoot
If something looks wrong
- The solution turns murky brown and does not stay clear.
- You did not add enough acid. Brown manganese dioxide formed. Ask your teacher to prepare a fresh sample with the full 10 mL of acid.
- The voltage reading jumps wildly on the screen.
- The stir bar hits the sensor or the electrode tip touches air bubbles. Adjust the clamp so the probe tip is securely under the surface.
- The sensor light blinks red and will not connect.
- Connect the Go Direct ORP sensor. Open the Sensor menu in Graphical Analysis. Tap the serial number of your sensor.
- The graph shows a diagonal ramp instead of a steep jump.
- You added permanganate too fast in big chunks. In your next trial, add drops slowly (one drop every two seconds) near 19 mL.

Clean up
Clean up like a scientist
- The teacher pours all pink reaction mixtures into the heavy metal chemical waste container.
- Rinse the ORP sensor with plenty of distilled water and screw it into its pH 4 storage bottle.
- The teacher drains permanganate that remains in the buret. The teacher rinses it fully with tap water.
- Wipe the Stir Station top clean with a damp paper towel. Wash your hands with soap.
Disposal: You must neutralise manganese and acidic waste or collect it in an approved school chemical waste jug. Do not pour heavy metal oxidisers down the regular drain.
Observation
When purple permanganate first dropped into the peroxide, the purple colour vanished almost immediately.
In the app, students agree or disagree from their own data.
Observation
Between 0 mL and 18 mL, the voltage reading stayed fairly flat near 620 to 650 millivolts.
In the app, students agree or disagree from their own data.
Observation
Near 20 mL, a single drop caused the liquid to keep a faint pink colour and the voltage leaped upward steeply.
In the app, students agree or disagree from their own data.
Observation
After the steep jump, adding more purple liquid made the voltage climb straight to infinity.
In the app, students agree or disagree from their own data.
Conclusion
Purple drops turn clear only while there is peroxide available to trade electrons with them.
Conclusion
The sudden steep jump in millivolts marks the turning point where every peroxide molecule has reacted.
Conclusion
The exact volume of purple liquid needed to trigger the voltage jump tells us the strength of the peroxide.
Think back
Think like a scientist
- Why was adding liquid drop by drop near the turning point so important?
- What visual sign warned you that the voltage jump was about to happen?
- How could this method tell if a bottle of peroxide in a hospital is too old to use?
Question 1
What does the Go Direct ORP sensor measure during the titration?
- The push of electrons traded in the liquid, measured in millivolts
- The temperature increase in degrees Celsius
- The total weight of liquid in grams
- The brightness of the room lights
Question 2
What colour change told you that all the peroxide had completely reacted?
- A permanent pale pink colour remained in the liquid
- The liquid turned dark green
- The liquid turned milky white
- The liquid stayed boiling hot
Question 3
On your titration curve, what feature marks the turning point of the reaction?
- The middle of the steep vertical cliff in voltage
- The very first data point at 0 mL
- The lowest dip in the line
- Where the line crosses the x-axis
Question 4
Why did the purple drops turn clear when added during the first 15 mL?
- Permanganate traded electrons with peroxide, destroying the purple colour
- The water in the beaker simply diluted the purple dye away
- The stir bar absorbed the purple dye like a sponge
- The sensor lamp bleached the liquid with light
Question 5
Why did the voltage suddenly shoot upward near 20 mL?
- All peroxide was used up, so unreacted oxidising liquid built up
- The battery in the sensor suddenly died
- The liquid reached boiling temperature
- The stir bar started spinning backwards
Question 6
If an old, degraded bottle of peroxide is tested, how will its turning point volume compare to fresh peroxide?
- It will need LESS purple liquid to reach the turning point
- It will need MORE purple liquid to reach the turning point
- It will need exactly the same amount of purple liquid
- The graph will never show any voltage jump at all
Question 7
Why must 4.5 M sulfuric acid only be handled and measured by an adult?
- It is highly corrosive, generates heat, and causes severe skin and eye burns
- It stains tables purple permanently
- It smells sweet and might be mistaken for fruit juice
- It is too cold to touch safely
Question 8
What could happen if the ORP sensor touches the spinning magnetic stir bar?
- The spinning bar can crack the delicate platinum glass electrode tip
- The stir bar will turn completely purple
- The tablet screen will switch off
- The liquid will instantly freeze solid
Question 9
Why did we switch from adding 1 mL at a time to single drops near 18 mL?
- To find the exact volume where the vertical jump happens without overshooting
- Because the buret was almost empty
- Because the stir bar stopped spinning
- To give the tablet time to recharge
Question 10
Which of these real-world facilities relies on ORP sensors to ensure safety?
- City drinking water plants testing disinfection punch
- Car repair garages checking tyre air pressure
- Bakeries weighing flour for bread
- Weather stations measuring wind speed
Question 11
If your solution turns muddy brown instead of staying clear, what likely went wrong?
- Not enough sulfuric acid was added to support the clean reaction
- The beaker was kept under too much light
- The stir bar was spinning too fast
- The tablet Bluetooth disconnected
Question 12
What is the correct way to store the Go Direct ORP sensor after cleaning it?
- Rinse with distilled water and seal in its bottle filled with storage solution
- Dry the tip with paper towels and leave it lying open on the table
- Submerge the entire sensor body inside a beaker of acid
- Store it inside the freezer

Try These
Fresh vs. Opened Peroxide
- Compare a brand new, sealed bottle of 3% peroxide against one opened six months ago.
- Titrate equal samples of both. Does the older bottle reach the turning point with less purple liquid?
- Calculate the difference in strength to find out how quickly household peroxide expires.

Try These
The First Derivative Peak
- Open Graphical Analysis and add a Calculated Column for 1st Derivative.
- Watch the S-curve transform into a sharp mountain peak.
- The very tip of that spike points directly to the exact turning point drop!

Try These
Automating with a Drop Counter
- Mount the Go Direct Drop Counter beneath a plastic reagent reservoir.
- Let purple drops fall steadily through the optical sensor beam.
- Watch the tablet plot every single drop automatically without any manual typing!

Challenge
Does Warmth Spoil Peroxide Faster?
- Store one sealed sample of peroxide in a cool refrigerator and another in a warm sunlit spot for two weeks.
- Titrate both with your teacher to measure which sample lost more of its strength.
- Why are medicine bottles always dark amber and labelled 'store in a cool place'?
Run this lab with your class
Students follow the same screens in the Stemious app, record live sensor data and take the quiz, and their work is saved to their record.
Where it fits in the syllabus
- Direct Class 11, Chemistry, chapter 1: Redox Reactions
Versions and what each needs
- How fresh is your peroxide?
Advanced Chemistry, 60 min, Based on a Vernier lab
Needs: Go Direct Drop Counter, Go Direct ORP Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.