Experiments › Environmental Science
How healthy is our stream?
Water Field Study
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 5 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can clear-looking river water hide dangerous invisible pollution?
Show the answer
Water that looks sparkling clean can still carry harmful acids or dissolved chemical salts. Today you will use three electronic environmental sensors to uncover the hidden health of water.

Introduction
The Secret Signs of Water Health
A river might look clean to your eyes, but is it safe for fish, frogs, and drinking? Environmental scientists don't just look at water. They test its temperature, electrical conductivity, and pH. Cooler water holds more life-giving oxygen. Low conductivity means water is free of excess chemical run-off. A steady pH between 6.5 and 8.2 keeps fish and stream insects alive. Today, you become an environmental detective to test water across different sites.
Driving question: How can three simple numbers tell us whether a river is healthy, polluted, or recovering?
What you will learn
Goals for this field study
- I can collect reliable water quality data using digital sensors.
- I can explain why cool water is generally healthier for stream life.
- I can relate high conductivity readings to dissolved ions and salts.
- I can determine if a river's pH is safe for fish and insects.
- I can analyze data across different sites to discover pollution or dilution patterns.
Why it matters: Clean water is essential for life on Earth. Cities, wildlife reserves, and fisheries rely on these exact tests every day to catch pollution early.
Safety first
Field and Laboratory Safety Rules
- Wear splash goggles and nitrile gloves when you collect or touch natural water.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Never enter deep water or stand on slippery, unstable stream banks. Stay at least one meter back on stable shore.
- Never taste or drink any water sample, even if it looks crystal clear. River water may contain microscopic bacteria.
- Keep all electronic devices and tablets on dry surfaces at least 30 cm away from open water beakers.
- Handle the glass bulb of the pH sensor with extreme gentleness; it is thin and fragile.
- Wash your hands fully with soap and warm water when your investigation is complete.
What you need
- Go Direct Temperature Probe1
- Go Direct Conductivity Probe1
- Go Direct pH Sensor1
- Tablet running Graphical Analysis1
- colorless plastic bottle2 to 4 bottles
- clear plastic cup2 to 4 cups
- Distilled water wash bottle1 bottle (250 mL)
- waste bucket1
- Splash goggles and nitrile gloves1 set per student

Step 1 of 5
Collect water samples safely
- Submerge the plastic bottle fully below the water surface at your sample site.
- Collect water about 1 metre from the shoreline where water flows gently.
- Fill the bottle to the very brim. Seal the cap tightly. Label the bottle with the site name.
- You wear goggles and gloves.
- An adult supervisor watches from the riverbank.
- The ground under your feet is dry, stable, and secure.
- Put on your safety goggles and light blue nitrile gloves.
Careful: You can slip into the river, drop bottles into fast currents, or touch contaminated water. Crouch on stable ground. Never lean out over deep water. An adult must supervise all sample collection at the riverbank.

Step 2 of 5
Measure water temperature
- Uncap your water sample bottle or pour 150 mL into a clean plastic cup.
- Insert the stainless steel probe deep into the water to match Figure 1.
- Stir gently for 20 seconds, and when the reading stays steady, record the temperature in your data table.
- The tablet is placed safely on a dry surface away from cups.
- The temperature probe tip is submerged at least 4 cm into the liquid.
- Turn on your Go Direct Temperature Probe and connect it in Graphical Analysis.
Careful: If you submerge the electronic handle of the probe into water, you can short-circuit the sensor. Only submerge the metal probe shaft. Keep the black handle and button dry.

Step 3 of 5
Measure electrical conductivity
- Place the conductivity probe into the same water sample.
- Gently swirl the probe once to displace any trapped air bubbles from the electrodes.
- Wait 10 seconds for the reading to stabilize. Record the conductivity in µS/cm.
- The sensor slot near the tip is clean and free of dirt flakes.
- The probe handle stays out of the liquid.
- Turn on the Go Direct Conductivity Probe and connect it in Graphical Analysis.
- Make sure that the slot at the tip of the probe is fully submerged in water.
Careful: Trapped air bubbles inside the electrode slot will cause falsely low readings. Swirl the probe gently in the water to remove bubbles before you take a reading.

Step 4 of 5
Measure water pH
- Rinse the glass bulb electrode with a stream of distilled water over the waste beaker.
- Place the pH probe into your water sample and swirl gently.
- Wait 20 to 30 seconds for the reading to stabilize. Record the pH in your table.
- The storage bottle cap is safely set aside without a spill of its buffer solution.
- The delicate glass bulb is intact and has not struck the cup walls.
- Turn on the Go Direct pH Sensor and connect it in Graphical Analysis.
- Carefully unscrew the storage bottle from the pH sensor and set it upright on the table.
Careful: If you bump the glass bulb against hard beaker walls, you can shatter the electrode. Lower the probe gently into the liquid center; never touch the glass bulb with fingers.

Step 5 of 5
Record observations and test other sites
- Examine the sample against white paper (clear, slightly muddy, yellowish). Note odor, algae, suds, or animals (ducks, insects, fish).
- Rinse all sensor probes with distilled water over the waste beaker.
- Repeat Steps 2 to 4 for the other sites (wastewater outflow, mixture zones, downstream points). Complete your table.
- All sensor probes are rinsed with distilled water between different sites.
- Hands stay gloved and away from eyes or mouth.
Careful: If you transfer droplets of high-salt wastewater into a clean river sample, you will spoil your comparison. Rinse each probe fully with distilled water before you put it into the next sample.
0 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 6, Science, chapter 2: Diversity in the Living World
- Direct Class 8, Science, chapter 6: Reproduction in Animals
- Direct Class 8, Science, chapter 13: Our Home: Earth, a Unique Life Sustaining Planet
- Direct Level DP, Environmental Systems and Societies, chapter 4: Water and aquatic food production systems and societies
Versions and what each needs
- How healthy is our stream? (pH and temperature)
Middle School Science, 60 min, Based on a Vernier lab
Needs: Go Direct Conductivity Probe, Go Direct pH Sensor, Go Direct Temperature Probe - How healthy is our stream? (flat pH and dissolved oxygen)
Agricultural Science, 90 min, Based on a Vernier lab
Needs: Go Direct Conductivity Probe, Go Direct Tris-Compatible Flat pH Sensor, Go Direct Optical Dissolved Oxygen Probe - How healthy is our stream? (dissolved oxygen and pH)
Biology with Vernier, 90 min, Based on a Vernier lab
Needs: Go Direct Conductivity Probe, Go Direct Optical Dissolved Oxygen Probe, Go Direct pH Sensor - How healthy is our stream? (dissolved oxygen, pH, temperature and turbidity)
Environmental Science, 60 min, Based on a Vernier lab
Needs: Go Direct Conductivity Probe, Go Direct Optical Dissolved Oxygen Probe, Go Direct pH Sensor, Go Direct Temperature Probe, Go Direct Turbidity Sensor