Experiments › Physical Science
How high can you pump pressure?
Fun with Pressure
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does a bicycle pump push back harder as you press it down?
Show the answer
Squashing air forces trillions of particles into a smaller space. Today, you and your team will compete to produce the highest air pressure possible inside a bottle.

Introduction
How High Can You Squash Air?
Every breath of air is packed with trillions of microscopic particles speeding around. They collide with everything, creating gas pressure. When you push down on a tire pump, you crowd those particles into a smaller space. In this challenge, your team gets a dry bottle, tubing, and a digital sensor. Your mission is to use teamwork and physics to create the highest pressure spike in the room.
Driving question: How high can your team push the air pressure inside a bottle using only your body and teamwork?
What you will learn
Today you will find out
- I can explain what causes gas pressure inside a closed bottle.
- I can name three ways to increase gas pressure.
- I can assemble an airtight container setup with tubing and stoppers.
- I can find the highest pressure peak on a graph.
- I can use body force safely to create maximum pressure in a container.
Why it matters: Engineers rely on gas pressure to design scuba gear, rocket thrusters, car airbags, and mountain bike suspensions.
Safety first
Challenge Rules for Safety
- Wear safety goggles throughout the activity to protect your eyes from stoppers that pop out.
- Purple gloves = teacher does it. Blue gloves = you do it.
- NEVER stomp, leap, or jump on plastic bottles. Extreme impacts can crack plastic or shoot stoppers dangerously.
- Use only your hands, body lean, and teammates. Do not use tools, vices, clamps, or heaters.
- Do NOT exceed 400 kPa. Pressure beyond 400 kPa can permanently damage the internal sensor transducer.
- Only use clean, completely dry plastic bottles. Never let liquids enter the sensor port.
What you need
- Go Direct Gas Pressure Sensor1
- Tablet running Graphical Analysis1
- Single-hole rubber stopper with stopper stem1
- Rigid-wall tubing with connector1 piece (approx. 40 cm)
- Clean, dry plastic bottles (various sizes)2 to 3 per team
- Safety goggles and nitrile gloves1 set per student

Step 1 of 7
Connect sensor to Graphical Analysis
- Press the power button once to turn on your Go Direct Gas Pressure Sensor.
- Open Graphical Analysis on your device. Tap Sensor Data Collection.
- Find the ID of your sensor. Connect with Bluetooth. Look for a green light that flashes.
- Device Bluetooth is enabled.
- Sensor battery is charged.
Careful: You connect to the sensor of another team by mistake. Check the 8-digit serial number on the sensor label before you pair devices.

Step 2 of 7
Attach tubing to the sensor
- Locate the white plastic connector port on the side of the gas pressure sensor.
- Push the white tube connector onto the port. Twist the connector half a turn clockwise.
- Do not over-tighten: a snug finger-tight turn creates a perfect seal.
- The tube is clean and free of dust or moisture.
- Connector threads are straight, not cross-threaded.
Careful: Too much force on the connector can break the plastic threads. Turn gently until it stops. Never use tools or extreme force.

Step 3 of 7 Teacher does this
Insert the stopper into your bottle
- Push the other end of the tube onto the white tapered stopper stem.
- Press the rubber stopper firmly into the mouth of your dry plastic bottle.
- Ask your teacher to check that the stopper fits tight and does not pop out.
- The plastic bottle is completely dry inside.
- Teacher verifies stopper size fits the bottle neck.
Careful: A loose stopper can pop out like a cork under high pressure. Only use rubber stoppers that seat firmly at least halfway into the bottle neck.

Step 4 of 7
Test your airtight seal
- Give the plastic bottle a gentle two-handed squeeze and hold it squeezed.
- Watch the live meter on your tablet: the pressure should jump up immediately.
- Apply squeeze pressure for 5 seconds. Check if the pressure stays steady or leaks down.
- If the pressure drops while you hold it, find and tighten the leak.
- Safety goggles are on.
- The tube has no kinks.
Careful: A hidden air leak makes all compression efforts fail. Listen for air leaks around the stopper or tube joint.

Step 5 of 7
Practice trial: test compression techniques
- Tap Collect to begin a practice run.
- Try a simple one-hand squeeze. Note the peak number on the graph.
- Now let two teammates apply pressure together with flat palms.
- Use warm hands to warm the bottle before you compress it.
- Notice which method gives the steepest climb.
- Everyone keeps safety goggles on.
- The sensor sits flat on the table and does not hang from its tube.
Careful: Tension on the tube while you compress the bottle can pull the sensor off the bench. Keep the bottle and sensor close together on the tabletop.
2 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 6, Science, chapter 1: The Wonderful World of Science
- Related Class 11, Physics, chapter 2: Mechanical Properties of Fluids
- Related Class 9, Chemistry, chapter 7: Study of Gas Laws
Versions and what each needs
- How high can you pump pressure? (Middle School Science)
Middle School Science, 50 min, Based on a Vernier lab
Needs: Go Direct Gas Pressure Sensor - How high can you pump pressure? (Physical Science)
Physical Science, 50 min, Based on a Vernier lab
Needs: Go Direct Gas Pressure Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.