Experiments › Chemistry
How much acid is in a few drops?
Microscale Titration
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can a single drop of liquid cancel out an acid?
Show the answer
Acids and bases cancel each other out to make neutral water and salt. Scientists call this neutralization, and today you will measure it drop by drop.

Introduction
How does an antacid cancel acid?
When stomach acid upsets your stomach, an antacid pill cancels it out. Scientists call this neutralization: an acid and a base combine to form harmless water and salt. Today, you will add base drop by drop to cancel an acid. You will discover the exact turning point where the acid completely disappears!
Driving question: Can you find the exact drop where an acid turns into salt water?
What you will learn
Today you will find out
- I can explain what happens when an acid mixes with a base.
- I can spot the exact drop where the pH jumps and the colour changes to pink.
- I can use drop counts from my graph to find the strength of an acid.
- I can safely collect drop-by-drop pH data using a micro-beaker.
- I can follow lab safety rules when handling dilute acid and base.
Why it matters: Water treatment plants, medicine makers, and food factories all use titration to test and balance liquids before they reach your home.
Safety first
Scientist Rules for Today
- Wear chemical splash goggles and gloves at all times. Dilute hydrochloric acid and sodium hydroxide can irritate skin and eyes.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Never taste or drink anything in the laboratory.
- Look for the ADULT NEEDED badge. Adults pour chemicals and tighten clamps.
- Hold dropper bottles straight up and down over the micro-beaker to avoid stray drips.
- If any chemical touches your skin, wash immediately with plenty of tap water.
- Wash your hands with soap after you finish the clean-up.
What you need
- Go Direct pH Sensor1
- ring stand with clamp1
- micro-beaker (cut storage bottle)1 · teacher
- 0.10 M Sodium hydroxide solution (in dropper bottle)10 mL
- HCl solution (unknown, in dropper bottle)5 mL
- Phenolphthalein indicator solution1 dropper bottle
- Distilled water wash bottle1
- wooden toothpicks2
- Tablet running Graphical Analysis1
- safety goggles1 pair per person

Step 1 of 7
Remove the sensor from storage and rinse
- Unscrew the storage bottle cap from your Go Direct pH Sensor.
- Carefully slide the storage bottle and cap off the glass probe body.
- Rinse the glass bulb tip over a waste container with distilled water from your wash bottle.
- Safety goggles are securely over your eyes.
- Waste container is placed directly under the probe tip.
Careful: The delicate glass bulb at the tip of the sensor can crack if bumped against hard surfaces. Hold the sensor handle firmly and never touch the glass bulb against the table or sink.

Step 2 of 7
Slide on the microbeaker cup
- Hold the pH sensor so that the tip points straight UP.
- Slide the cut microbeaker bottle and its screw cap down onto the probe shaft, small neck first.
- Position it so the glass tip sticks up about 1 cm inside the bowl, then gently tighten the cap.
- The sensor tip points upward.
- The cut edges of the plastic bottle are smooth.
- The cap O-ring makes a liquid-tight seal around the sensor body.
Careful: If you tighten the plastic cap too much, you can crack the collar or strip the plastic threads. Tighten gently with your fingers until snug; do not force it.

Step 3 of 7 Teacher does this
Clamp the sensor to the ring stand
- An adult clamps the utility clamp firmly to the ring stand rod.
- Clamp the prongs around the bottle lid collar so the sensor stands completely upright.
- Make sure the sensor is firm and level so liquid will not spill out of the micro-cup.
- The ring stand base rests flat on the table.
- The utility clamp thumbscrews are firmly hand-tightened.
- Sensor points straight up vertically.
Careful: If the clamp slips, the sensor could fall and shatter its glass bulb. An adult tightens the clamp around the sturdy bottle cap. Do not squeeze the fragile glass bulb.

Step 4 of 7
Add the acid, indicator, and water
- Hold the unknown HCl dropper bottle completely vertical. Add exactly 10 drops into the micro-beaker.
- Add 1 drop of phenolphthalein indicator dye.
- Use your wash bottle to add distilled water to cover the glass bulb tip. Stir gently with a clean toothpick.
- Goggles are on.
- The dropper bottle is held straight up and down, not at an angle.
- A clean toothpick is ready to stir the liquid.
- The liquid stays completely clear after you stir it.
Careful: Hydrochloric acid causes skin irritation and eye damage if splashed. If you tilt the dropper bottle, the drops become uneven. Keep your eyes protected. Hold the bottle strictly vertical directly over the cup. Wipe any exterior bottle drips with a tissue.

Step 5 of 7
Record drop zero (the starting acid pH)
- In Graphical Analysis, tap Mode, select Event Based, enter Volume for Event Name and drops for Units, then tap Done.
- Tap Collect in Graphical Analysis.
- Tap Keep. Type '0' for drops. Tap Keep Point.
- No NaOH base has been added yet.
- The live pH reading on screen is steady.
- Your very first dot is now logged on the graph at Volume = 0 drops.
- Before you add any base, wait until the live pH reading stabilizes around pH 2.
Careful: If you save a point before the reading settles, you record inaccurate data. Wait 3 to 5 seconds until the live number on screen becomes stable.
2 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 7, Science, chapter 2: Exploring Substances: Acidic, Basic, and Neutral
Versions and what each needs
- How much acid is in a few drops?
Chemistry with Vernier, 50 min, Based on a Vernier lab
Needs: Go Direct pH Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.