Experiments › Chemistry
How much acid is in your drink?
Drinking Acid
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Did you know that fruit juices and fizzy sodas are packed with acid?
Show the answer
That bright tart flavour in sodas and juices comes from food acids. Today you will measure their pH and neutralize the acid drop by drop to find the exact amount inside.

Introduction
Are You Really Drinking Acid?
When you take a sip of lemon soda or orange juice, you taste a sharp tang. That sour taste comes from acids like citric and phosphoric acid. But how acidic are these drinks compared to water? In this experiment, you will test the pH of common beverages using a digital pH sensor. Then you will add drops of a basic liquid to neutralize the acid and discover exactly how much acid is hiding in your drink.
Driving question: Why do your favourite drinks taste sharp, and how much acid are you actually drinking?
What you will learn
What You Will Discover
- I can test and compare the pH of different everyday drinks.
- I can explain what pH numbers tell us about acids and bases.
- I can run a step-by-step titration using a buret and pH sensor.
- I can find the neutralization turning point on a graph to compare acid amounts.
- I can describe why food makers add acids to drinks and how they affect teeth.
Why it matters: Dentists track drink acids to protect teeth, while beverage companies balance acid to keep flavours fresh and stop bacteria from growing.
Safety first
Safety Rules for the Lab
- Wear chemical splash goggles and protective gloves at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Sodium hydroxide solution is a strong base that irritates eyes and skin.
- Only an adult fills the buret with sodium hydroxide solution.
- Never taste or drink any liquid in the lab, even commercial juices.
- The pH sensor has a delicate thin glass bulb; never tap it against the beaker.
- Rinse skin immediately with plenty of tap water if any chemical touches you.
What you need
- Go Direct pH Sensor1
- Stir Station1
- Electrode Support1
- buret1 (50 mL) · teacher
- buret clamp1
- 250 mL beaker3
- 0.10 M Sodium hydroxide solution100 mL (diluted to 0.05 M) · teacher
- magnetic stir bar1
- measuring pipet1 (10 mL) with pump
- Distilled water wash bottle1
- commercial liquids5 beverage samples (30 mL each)
- Tablet running Graphical Analysis1

Step 1 of 8
Prepare the pH Sensor
- Unscrew the storage bottle cap and gently slide the electrode out.
- Rinse the glass tip fully with distilled water into a waste beaker.
- Place the tip into a beaker of pH 7 soak solution.
- Splash goggles and gloves are on.
- Loosen the storage bottle cap before you remove the sensor.
- A waste beaker sits below the sensor during the rinse.
- The Go Direct pH Sensor is turned on and connected over Bluetooth in Graphical Analysis (tap the i button for help).
Careful: If you pull the sensor before you loosen the cap, you can break the glass electrode. Always unscrew the plastic cap completely before you gently pull the sensor out.

Step 2 of 8
Measure Starting Beverage pH
- Lift the sensor from the soak beaker. Rinse it with distilled water.
- Lower the sensor into the drink and swirl gently.
- Wait 10 seconds. Record the beverage name and pH value in your notebook.
- You rinsed the sensor after the soak solution.
- The drink sample is at room temperature.
- You are ready to record the number once it stabilizes.
- Measure 30 mL of your first drink into a clean 250 mL beaker.
Careful: Vigorous movement of the sensor can hit the beaker wall and crack the bulb. Swirl the liquid gently around the sensor. Do not hit the glass beaker.

Step 3 of 8
Rinse Sensor and Test Other Drinks
- Remove the sensor. Rinse its tip fully with distilled water.
- Dip the sensor briefly into the soak buffer. Rinse it again.
- Repeat the pH test for each assigned beverage sample. Record each value in your data table.
- The sensor is rinsed between every single beverage sample.
- Waste rinse water is collected in a separate beaker.
- Never mix different drinks together.
Careful: Leftover drink on the sensor bulb will contaminate the next sample. Rinse fully with distilled water until the bulb is spotless.

Step 4 of 8
Prepare Diluted Beverage for Titration
- Use the markings on a 250 mL beaker to add 50 mL of distilled water.
- Use a 10 mL pipet and pump to add exactly 10.0 mL of your assigned drink.
- Place a small magnetic stir bar into the beaker.
- Use a pipet pump; never mouth-pipet any liquid.
- The beaker is clean and dry before you add water.
- The stir bar is lowered gently so it does not splash.
- A clean 250 mL beaker is placed on the centre of the Stir Station platform.
Careful: If you drop the magnetic stir bar, you can crack the bottom of the glass beaker. Tilt the beaker slightly and slide the stir bar down the inner wall gently.

Step 5 of 8 Teacher does this
Fill the Buret with Base
- Use a small funnel to fill the buret above the 0 mL mark.
- Drain a few drops into a waste beaker to fill the buret tip completely.
- Record the start liquid volume at exactly 0.0 mL.
- The adult wears splash goggles and purple chemical-resistant gloves.
- Remove the funnel from the top of the buret after you fill it.
- The buret stopcock is closed tight before you pour.
- The 50 mL buret is clamped to the Stir Station support post and rinsed with 0.05 M sodium hydroxide solution.
Careful: Sodium hydroxide solution can splash into eyes if you pour it above eye level. Lower the buret to chest height to fill. Never pour chemical above eye level.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 10, Science, chapter 2: Acids, Bases and Salts
- Related Level AS & A Level, Chemistry, chapter 8: Equilibria
Versions and what each needs
- How much acid is in your drink? (pH)
Food Chemistry, 60 min, Based on a Vernier lab
Needs: Go Direct pH Sensor - How much acid is in your drink? (drop counter)
Food Chemistry, 55 min, Based on a Vernier lab
Needs: Go Direct Drop Counter, Go Direct pH Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.