Experiments › Biology
How much air can your lungs hold?
Lung Volume
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
How much air moves in and out of your lungs each day?
Show the answer
You breathe over twenty thousand times a day without thinking. Today you will measure your quiet breaths and your biggest breath using a digital airflow sensor.

Introduction
How Much Air Can Your Lungs Hold?
Your lungs work like flexible bellows. When chest muscles pull outward, air rushes in. During quiet resting breaths, you only use a tiny slice of your total lung space. But when you sprint, swim, or sing, your body calls on hidden air reserves. Today you will capture your breathing rhythm on screen and discover how many litres your lungs can hold.
Driving question: How much air can your lungs actually hold when you take the deepest breath possible?
What you will learn
Today you will discover
- I can measure and find resting tidal volume on a graph.
- I can calculate vital capacity and reserve volumes from breathing data.
- I can assemble and zero the spirometer safely and correctly.
- I can follow hygiene rules so mouthpieces and filters are never shared.
- I can explain how lung capacity relates to athletics and health.
Why it matters: Doctors check lung capacity to spot asthma and allergies. Athletes track lung volume to build endurance.
Safety first
Hygiene and Breathing Rules
- Wear light blue gloves and goggles while you assemble and handle test gear.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Every volunteer must use their OWN new disposable mouthpiece and bacterial filter.
- Never share mouthpieces or filters between students. Dispose of used ones immediately.
- If you feel light-headed or dizzy at any point, stop blowing immediately and sit calmly.
- Students with colds, flu, or asthma flare-ups should record data instead of blowing.
- Wipe the plastic nose clip with a disinfectant wipe between different users.
- Wash your hands with soap after you handle used mouthpieces.
What you need
- Go Direct Spirometer1 per group
- Disposable bacterial filter1 per testing subject
- Disposable mouthpiece1 per testing subject
- nose clip1 per group
- Tablet running Graphical Analysis1 per group
- Disinfectant wipes1 pack per class

Step 1 of 8
Assemble the bacterial filter and mouthpiece
- Find the Inlet side marked on the spirometer head.
- Firmly push the larger diameter side of the bacterial filter onto the Inlet side.
- Attach a clean disposable mouthpiece to the other end of the filter.
- The mouthpiece is brand new and freshly unpacked.
- The filter has never been used by another person.
- Your hands are clean and gloved.
- Make sure the pieces fit tightly so no air leaks through the sides.
Careful: Do not share mouthpieces or filters. Germs can spread between students. Use only your assigned filter and mouthpiece. Never let anyone else use them.

Step 2 of 8
Connect the sensor to your tablet
- Press the power button once to turn on your Go Direct Spirometer.
- Open Graphical Analysis on your device. Tap Sensor Data Collection.
- Connect to your spirometer with Bluetooth.
- The sensor battery is charged.
- Bluetooth is enabled on your device.
- Confirm the app displays Flow Rate and Volume channels.
Careful: Connecting to another group's sensor leads to confusing data. Check the sensor ID code on the back label before you select it in the app.

Step 3 of 8
Set experiment time to 60 seconds
- Tap Mode in the bottom left corner of Graphical Analysis.
- Change the experiment duration to 60 seconds.
- Tap Done to save your settings.
- The collection mode is set to Time Based.
- End time is set to 60 s.
- Make sure that Time Based collection is selected.
Careful: If you end data collection too early, you cut off the vital capacity breath. Set duration to 60 seconds so you have plenty of time for calm breaths and deep breaths.

Step 4 of 8
Brace arms and zero the sensor
- Sit comfortably with elbows firmly braced on the table.
- Hold the spirometer vertical and still. Do not breathe through the spirometer during zero calibration.
- Tap the Flow Rate meter on the screen. Select Zero to balance the reading.
- The subject's forearms rest flat on the sturdy table.
- The sensor is held completely upright.
- No person blows or waves hands near the flow head.
- Do NOT breathe through the mouthpiece yet.
Careful: Movement or tilt of the sensor during zero calibration causes false air currents that change volumes. Brace your arms. Hold the sensor still while you tap Zero.

Step 5 of 8
Attach nose clip and prepare to breathe
- Place the blue plastic nose clip securely over the subject's nostrils.
- Put the mouthpiece between your lips. Close your lips tightly around it.
- Keep teeth outside the mouthpiece opening and do not block the air channel with your tongue.
- The nose clip pinches gently and does not cause pain.
- Lips form a complete, tight seal around the mouthpiece.
- The sensor remains vertical.
- Make sure that you breathe only through the mouth.
Careful: Air that escapes through the nose or lips causes low volume readings. Make sure that the nose clip is snug and lips seal completely around the tube.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 11, Biology, chapter 14: Breathing and Exchange of Gases
- Direct Level AS & A Level, Biology, chapter 9: Gas exchange
- Direct Level DP, Sports, Exercise and Health Science, chapter 2: Exercise Physiology
- Direct Level DP, Biology, chapter B3.1: Gas Exchange
Versions and what each needs
- How much air can your lungs hold?
Human Physiology Vol 2, 60 min, Based on a Vernier lab
Needs: Go Direct Spirometer
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.