How much calcium is in tap water?

Calcium and Water Hardness

Grades 7-8Environmental Science1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

A shiny chrome tap and tea kettle covered with crusty white mineral limescale deposits

Wonder

Why does tap water leave white chalky crust on bathroom taps and kettles?

Show the answer

Water dissolves invisible minerals from underground rocks. When this hard water dries or boils, calcium leaves behind crusty limestone rock. Today you will measure these dissolved minerals with an electronic ion sensor.

A domestic chrome water tap showing crusty white mineral scale around the spout

Introduction

The Mystery of Hard Water

Have you ever washed your hands and noticed soap will not make bubbly suds? Instead, it leaves sticky grey scum. You might also see chalky white crust around taps, shower heads, and kettles. That white crust comes from dissolved minerals, mainly calcium from underground limestone rock. Water with lots of calcium is called hard water. Today, you will test water samples to measure dissolved calcium and find out how hard water really is.

Driving question: Why does tap water leave crusty white stains, and how hard is our water?

What you will learn

Today you will find out

  • I can explain how rocks dissolve to make water hard.
  • I can calibrate a calcium sensor using high and low standards.
  • I can measure the calcium level of a water sample accurately.
  • I can calculate calcium hardness in milligrams per litre.
  • I can explain how water hardness affects aquatic wildlife and plumbing.

Why it matters: Water treatment plants, boiler engineers, and river ecologists all track water hardness. Too much calcium clogs city pipes, while too little harms river creatures.

Safety first

Lab Rules for Today

  • Wear safety goggles, nitrile gloves, and a lab coat or apron at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Never drink any lab water or standard solutions. Never drink from lab glassware.
  • Handle the calcium electrode very gently. The delicate tip membrane tears easily if poked.
  • Never wipe or rub the electrode tip with force. Only blot drops gently with soft tissue.
  • Keep tablet electronics at least 30 cm away from all liquids.
  • Wash your hands with soap and warm water when you finish.

What you need

  • Go Direct Calcium ISE1
  • Tablet running Graphical Analysis1
  • High Standard (1000 mg/L Ca2+)30 mL
  • Low Standard (10 mg/L Ca2+)30 mL
  • 100 mL beakers3
  • Distilled water wash bottle1
  • waste container1
  • Lint-free tissue box1 box
  • Splash goggles and nitrile gloves1 set per student
Student holding the pre-soaked Calcium ISE upright in the soaking bottle

Step 1 of 8

Check sensor soaking and wake probe

  1. Make sure the Calcium ISE probe has soaked in High Standard for at least 30 minutes.
  2. Fully submerge the small white reference dots on the probe shaft.
  3. The sensor tip must not touch the bottom of the bottle.
  4. Press the power button on the sensor once. The LED light blinks red.
Stop and check
  • Put on goggles and nitrile gloves.
  • Table is clean, flat, and dry.
  • The sensor was pre-soaked in High Standard.

Careful: An unsoaked electrode gives numbers that drift wildly and are inaccurate. Always make sure the electrode tip has soaked for at least 30 minutes in High Standard before you measure.

Tablet screen displaying Graphical Analysis sensor connection with blinking green light on probe

Step 2 of 8

Connect sensor to Graphical Analysis

  1. Open Graphical Analysis on your tablet.
  2. Tap 'Sensor Data Collection'.
  3. Find your Calcium ISE in the list. Tap 'Connect'.
  4. The sensor LED changes from red flashes to green flashes.
Stop and check
  • Bluetooth is turned on on the tablet.
  • Tablet is kept 30 cm away from liquid bottles.

Careful: Standard solution can ruin the tablet screen if it spills. Keep the tablet to one side and handle bottles with two hands.

Student holding probe in High Standard bottle while tablet shows Reading 1: 1000 mg/L

Step 3 of 8

Calibrate reading 1 in High Standard

  1. Keep the probe in the High Standard (1000 mg/L Ca2+).
  2. In the app, tap the sensor meter in the bottom corner and choose 'Calibrate'.
  3. For Reading 1, enter 1000 mg/L.
  4. Swirl gently once, hold still, and wait for the voltage reading to stabilize.
  5. When the reading stays steady, tap 'Keep'.
Stop and check
  • Probe tip is fully covered in High Standard.
  • White reference dots on the shaft are under liquid.
  • No air bubbles are trapped beneath the flat tip.

Careful: Bubbles against the tip make the voltage jump erratically. Gently tap the probe inside liquid to release any bubbles.

Student rinsing the probe tip with distilled water over a waste beaker

Step 4 of 8

Rinse and blot probe thoroughly

  1. Lift the Calcium ISE out of the High Standard.
  2. Hold the probe over the waste beaker. Rinse the shaft fully with distilled water from the wash bottle.
  3. Take a fresh lint-free tissue and gently blot water droplets from the shaft.
  4. Do not rub or scrub the sensitive membrane at the very tip!
Stop and check
  • Waste beaker is directly under the probe.
  • Use pure distilled water. Never use tap water to rinse.

Careful: Droplets of High Standard ruin the calibration if they enter Low Standard. Rinse with plenty of distilled water. Gently blot dry before you move to Low Standard.

Probe placed in Low Standard bottle while tablet shows Reading 2: 10 mg/L

Step 5 of 8

Calibrate reading 2 in Low Standard

  1. Place the tip of the probe into the Low Standard (10 mg/L Ca2+).
  2. Submerge the white reference dots. Do not let the tip touch the bottom.
  3. Type 10 mg/L for Reading 2.
  4. Swirl gently, hold still, and wait about 60 seconds for the voltage to settle.
  5. When stable, tap 'Keep', then tap 'Apply' to save the calibration.
Stop and check
  • Low Standard bottle is clean and unclouded.
  • No bubbles trapped under the probe tip.

Careful: If you save the calibration before you wait 60 seconds, readings become inaccurate. Wait until the voltage digits do not change. Then tap Keep.

3 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

ICSE (CISCE)
  • Related Class 9, Chemistry, chapter 3: Water

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.