Experiments › Environmental Science
How much chloride is in our water?
Chloride and Salinity
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why can sea fish not survive in a freshwater river?
Show the answer
Oceans are packed with dissolved salt particles called ions. Most river fish cannot handle so much salt. Today you will measure invisible chloride ions to reveal exact water saltiness.

Introduction
The Mystery of Invisible Salts
A glass of ocean water looks just as clear as tap water. Yet drinking ocean water makes you thirsty, and freshwater fish cannot live in it. Where does all that salt hide? When salt dissolves, it breaks into invisible floating particles called ions. In seawater, chloride ions make up over half of all dissolved salts. By counting chloride ions with an electric sensor, we can tell exactly how salty any water sample is.
Driving question: How can a single sensor measure the invisible saltiness of river and ocean water?
What you will learn
Today you will find out
- I can explain where chloride ions come from in water.
- I can calibrate the chloride sensor using high and low standards.
- I can measure chloride levels in different water samples accurately.
- I can convert chloride readings into water salinity.
- I can explain how salt levels affect river and ocean life.
Why it matters: Wildlife rangers, water engineers, and marine biologists monitor salinity to protect drinking water and save aquatic habitats.
Safety first
Lab Rules for Today
- Wear safety goggles, lab gloves, and an apron at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Never taste or drink any test liquids or standards in the laboratory.
- Keep all water bottles and beakers at least 30 cm away from tablets and power cords.
- Handle the glass probe gently. Never press the tip against the bottom of a beaker.
- Rinse the probe tip with distilled water over a waste beaker between tests.
- Wash your hands fully with soap and warm water when you finish.
What you need
- Go Direct Chloride ISE1
- Tablet running Graphical Analysis1
- High Standard (1000 mg/L Cl-)30 mL
- Low Standard (10 mg/L Cl-)30 mL
- Distilled water wash bottle1
- 250 mL beaker1
- 100 mL beakers3
- Lint-free tissue box1 box
- Splash goggles and nitrile gloves1 set per person

Step 1 of 8
Check the pre-soaked electrode
- Look at the tip of your Go Direct Chloride ISE in its soak bottle.
- Check that the small white reference junction near the tip is completely underwater.
- Goggles and gloves are on.
- The sensor bottle stands securely.
- Hands are dry.
- Sensor tip has soaked in High Standard for at least 30 minutes (notify your teacher if not).
Careful: A dry electrode takes hours to give stable readings. Make sure that the electrode soaked in High Standard before you continue.

Step 2 of 8
Connect the sensor to your tablet
- Press the power button on the Go Direct Chloride ISE once so the light flashes red.
- Open Vernier Graphical Analysis on your tablet. Tap Sensor Data Collection.
- Select your Chloride ISE from the device list until the light flashes green.
- Tablet Bluetooth is turned on.
- Table surface is dry around the tablet.
Careful: Liquid that splashes on the tablet can damage electronic circuits. Keep the tablet at least 30 cm away from open beakers.

Step 3 of 8
Calibrate reading 1: High Standard
- Tap the Chloride sensor meter on your tablet screen and choose Calibrate.
- With the probe in the High Standard (1000 mg/L), swirl gently, then hold still.
- Wait 60 seconds for steady voltage. Type 1000 for Value 1. Tap Keep.
- Probe is in the 1000 mg/L High Standard bottle.
- Tip does not rest directly against the bottle bottom.
Careful: If you tap Keep when voltage drifts, the calibration is inaccurate. Watch the live voltage number. Wait until the number does not change before you tap Keep.

Step 4 of 8
Rinse and blot the probe tip
- Carefully lift the Chloride ISE out of the High Standard bottle.
- Hold the probe over your waste beaker. Squirt the tip fully with distilled water.
- Gently blot the outside of the probe dry with a clean lint-free tissue.
- Waste beaker is positioned right under the probe tip.
- Clean lint-free tissue is ready in hand.
- Never rub the flat sensor membrane at the bottom.
Careful: Concentrated salt drops carried into the low standard ruin the second calibration point. Rinse generously with distilled water and gently blot off droplets.

Step 5 of 8
Calibrate reading 2: Low Standard
- Place the clean probe tip into the Low Standard bottle (10 mg/L Cl-).
- Swirl gently once, then hold still for 60 seconds.
- Type 10 for Value 2 on the tablet. Wait for steady voltage. Tap Keep, then Apply.
- You rinsed the probe before it entered Low Standard.
- The sensor is held steady and does not hit the glass.
- Make sure that the probe tip is submerged 30 mm and does not touch the bottom.
Careful: If you move the probe during voltage stabilization, it produces false slope calculations. Keep your hand still or support the probe in an electrode clamp.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Level DP, Environmental Systems and Societies, chapter 4: Water and aquatic food production systems and societies
Versions and what each needs
- How much chloride is in our water?
Water Quality, 50 min, Based on a Vernier lab
Needs: Go Direct Chloride Ion-Selective Electrode
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.