Experiments › Chemistry

How much copper is in brass?

Copper in Brass

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

A gleaming golden brass trumpet resting on a wooden table in warm sunlight

Wonder

Can light reveal what is hidden inside golden brass?

Show the answer

Brass looks like pure gold, but it is an alloy of copper and zinc. Today you will measure the exact copper inside using light absorption.

Everyday golden brass objects including keys, a padlock, and a trumpet on a wooden surface

Introduction

Unlocking the Metal Mystery

Look at a brass key, a trumpet, or a shiny door handle. They gleam like gold, but they contain zero gold! Brass is an alloy, a solid mix of copper and zinc melted together. Different brass items need different amounts of copper to stay strong, resist rust, or sound musical. But how can you test how much copper is inside without ruining the object? Chemists take a tiny sample into liquid and use light as a measuring tape. Blue copper solutions swallow red light, while zinc lets all light pass through. Today, you will use light to crack the secret recipe of brass.

Driving question: How can measuring beams of light passing through a liquid reveal the exact amount of copper locked inside solid brass?

What you will learn

Your Mission Today

  • I can explain what an alloy is and why dissolved brass turns blue.
  • I can choose the best light colour so other metals do not interfere.
  • I can prepare standard dilutions and record their light absorption.
  • I can use my graph line to find the copper percentage in brass.
  • I can safely handle glassware and observe chemical reactions under adult supervision.

Why it matters: Engineers and jewelers test metal alloys with light every day to guarantee airplanes, electronics, and instruments never fail.

Safety first

Lab Rules and Chemist Roles

  • Wear splash goggles, chemical-resistant gloves, and an apron at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • 6 M nitric acid is corrosive and dangerous. Only the teacher handles acid in the fume hood.
  • Nitric acid reactions produce toxic reddish-brown gas. The fume hood sash stays down.
  • Copper and iron solutions can irritate eyes and skin. Never touch or taste them.
  • Handle small glass cuvettes and volumetric flasks gently to prevent cracks.
  • Wash hands fully with soap and water before you leave the lab.

What you need

  • Go Direct SpectroVis Plus Spectrophotometer1 per group or station
  • Plastic cuvette (4 clear sides)2 cuvettes with lids
  • brass samples: 1 g each1 sample (~1.0 g) · teacher
  • 6 M nitric acid, HNO3, solution10 mL (fume hood only) · teacher
  • 0.20 M copper (II) nitrate solution40 mL in a beaker
  • Distilled water wash bottle1 bottle (150 mL)
  • 10 mL graduated cylinders and test tubes1 cylinder, 5 test tubes, 1 rack
  • Plastic Beral pipets and lint-free tissue3 pipets, 1 pack of wipes
  • 100 mL volumetric flask1 flask with stopper
  • Splash goggles and nitrile gloves1 set per person
Student weighing golden brass shavings on an analytical balance

Step 1 of 9

Weigh the brass sample

  1. Place a clean watch glass on the digital balance and press zero (tare).
  2. Carefully transfer about 1.0 g of dry brass turnings onto the watch glass.
  3. Record the exact mass in your notebook (for example, 0.94 g).
Stop and check
  • The balance reads 0.00 g with the empty dish on it.
  • You wear gloves to keep oils off the metal.

Careful: Metal turnings can scatter or prick fingers if handled roughly. Use plastic forceps or a spatula to move brass shavings gently.

Teacher reacting brass and nitric acid inside a glass fume hood

Step 2 of 9 Teacher does this

Teacher dissolves brass in the fume hood

  1. The teacher places the brass into a 150 mL beaker inside the fume hood.
  2. The teacher carefully pours 10 mL of 6 M nitric acid over the brass.
  3. Cover with a watch glass. Watch the reaction bubble and turn emerald green.
Stop and check
  • The fume hood blower is ON and operates.
  • The teacher wears purple acid-resistant gloves and a face shield.
  • Students stand at least 1 metre back from the glass sash.
  • Toxic brown gas forms inside the closed hood: never open the sash.

Careful: 6 M nitric acid causes severe chemical burns. Nitrogen dioxide gas is toxic if inhaled. Adult only. Do strictly inside the hood with the sash pulled down.

Liquid being filled to the 100 mL mark on a volumetric flask

Step 3 of 9 Teacher does this

Dilute the reacted brass to 100 mL

  1. Carefully pour the liquid into a 100 mL volumetric flask.
  2. Rinse the beaker three times with 5 mL water. Add each rinse to the flask.
  3. Add water drop by drop until the bottom of the blue curve touches the line.
Stop and check
  • The reaction is fully finished and no brown fumes remain.
  • The volumetric flask sits upright on a flat bench.
  • Metal is fully dissolved, gas has cleared, and 50 mL distilled water is added to the beaker.

Careful: The solution is still acidic. Splashes can burn skin or damage clothes. Pour slowly with a small glass funnel. The teacher oversees the final fill.

Graph showing absorption curves of copper, zinc, and iron ions

Step 4 of 9

Observe spectra of different metal ions

  1. Notice that zinc solutions have flat lines (absorbance near 0.0) everywhere.
  2. Observe that iron absorbs blue-green light below 550 nm, but drops to zero after 600 nm.
  3. Observe that copper has a huge absorption hill that peaks between 650 nm and 800 nm.
Stop and check
  • Spectra files are open on the screen.
  • Review the wavelength axis from 400 nm to 800 nm.

Careful: If you pick a wavelength below 550 nm, iron will absorb light and fake copper readings. Choose a wavelength where only copper absorbs light: between 620 nm and 700 nm.

Student preparing five test tubes of blue copper solutions

Step 5 of 9

Prepare five copper standard dilutions

  1. Label five clean test tubes: 1, 2, 3, 4, and 5.
  2. Use your 10 mL cylinder to measure 0.20 M copper stock and water as shown in the table.
  3. Swirl each tube gently to see five precise shades of blue, each slightly paler than the one before it.
Stop and check
  • Test tubes stand securely in the rack.
  • You have one pipet for copper stock and one for distilled water.

Careful: If you mix up pipets, you contaminate the stock liquid and make dilution numbers wrong. Keep pipets separate. Measure the liquid volume at the bottom of the curve.

4 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 12, Chemistry, chapter 4: The d- and f-Block Elements
ICSE (CISCE)
  • Direct Class 10, Chemistry, chapter 7: Metallurgy
Cambridge AS & A Level
  • Related Level AS & A Level, Chemistry, chapter 24: Transition elements

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.