Experiments › Chemistry
How much iron is in your vitamin?
Iron in Vitamin
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
How can doctors know if a pill has real iron inside without using a magnet?
Show the answer
Iron dissolved in water cannot be picked up with a magnet. Mixing it with a special tester turns it orange-red, soaking up green light. Scientists call this light absorption, and today you will measure it.

Introduction
The Metal Hidden in Your Vitamin
Your body needs iron to build red blood cells that carry oxygen to your brain and muscles. Multivitamins provide this iron, but it does not look like nails or steel washers. It is dissolved as invisible particles called ions. In this experiment, you will turn those invisible iron particles into a bright orange-red liquid. By measuring how much green light the liquid swallows, you will discover the exact amount of iron packed inside one tablet.
Driving question: How can shining coloured light through a vitamin drink reveal the hidden iron inside?
What you will learn
Goals for this investigation
- I can explain how an indicator makes invisible iron visible as a coloured liquid.
- I can calibrate a colorimeter and measure absorbance for a series of known solutions.
- I can identify that higher iron strength gives higher absorbance.
- I can use a calibration line to find the iron concentration in an unknown sample.
- I can describe how factories and labs verify nutrient levels on food labels.
Why it matters: Food companies, water inspectors, and doctors use colorimeters daily to ensure medicines, drinking water, and foods have exact nutrient levels.
Safety first
Essential Lab Safety Rules
- Wear safety goggles, lab aprons, and nitrile gloves at all times. Dilute hydrochloric acid and indicators can irritate eyes and skin.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Steps with the ADULT NEEDED badge boil acid on a hot plate. Students must stand back when you heat the acid.
- Never taste any lab liquid or touch vitamin solutions to your mouth.
- Keep all liquids at least 30 cm away from the tablet and colorimeter. Wipe up any droplets immediately.
- Handle cuvettes only by the ribbed upper rim. Never touch the clear optical windows.
What you need
- Go Direct Colorimeter1 per group
- Plastic cuvette (4 clear sides)1 with cap
- Tablet running Graphical Analysis1 per group
- mortar and pestle1 set
- multivitamin tablet1 tablet (approx 18 mg iron)
- laboratory hot plate1 per station · teacher
- 100 mL beakers2 beakers
- 10 mL graduated cylinders2 cylinders
- 50 mL graduated cylinder1 cylinder
- Test tubes and rack5 test tubes (20 x 150 mm) in rack
- glass funnel1 funnel with filter paper
- clear solution in a reagent bottleSet of Solutions A, B, C, D and 0.010 M HCl

Step 1 of 9
Weigh and crush the vitamin tablet
- Weigh your multivitamin tablet on the digital balance and write down its mass in grams.
- Record the milligrams of iron listed on the vitamin bottle label (usually 18 mg).
- Place the tablet into the mortar and grind it with the pestle into a fine, smooth powder.
- Weigh out exactly 0.200 g of the powdered tablet. Leave hard outer shell flakes behind.
- Wear your safety goggles and lab apron.
- Make sure that the mortar and pestle are completely dry.
- Keep the balance clean of stray powder.
Careful: Powder can puff into the air or eyes if crushed too aggressively. Press and twist firmly. Do not hit the tablet hard.

Step 2 of 9
Mix tablet powder with acid and water
- Transfer the 0.200 g of tablet powder into a clean 100 mL beaker.
- Use a graduated cylinder to measure 20 mL of 0.010 M hydrochloric acid (HCl).
- Add the 20 mL acid and 10 mL of distilled water to the beaker.
- Stir fully with a glass rod for 1 minute to help the iron dissolve.
- Wear your nitrile gloves and goggles.
- Work over a lab tray to catch drips.
- Pour dilute acid slowly.
Careful: Dilute hydrochloric acid can cause skin and eye irritation if splashed. Pour gently near the rim. Rinse skin immediately with cold water if acid touches it.

Step 3 of 9 Teacher does this
Adult boils the mixture to extract iron
- An adult places the beaker onto the hot plate and brings the liquid to a gentle simmer.
- Boil gently for 5 to 7 minutes. Stir occasionally with the glass rod.
- Turn off the hot plate. Let the beaker cool to room temperature on a heat-resistant pad.
- Notice that some powdery filler material remains undissolved. That is completely normal.
- Adult wears heat-resistant gloves, apron, and safety goggles.
- Hot plate cord is kept flat away from walkways.
- Students stand one step back from the heat station.
Careful: Acid that boils creates steam and hot splatters that can cause burns. Adult regulates heat to a gentle boil only. Use beaker tongs to move hot glassware.

Step 4 of 9
Filter and dilute to 50 mL
- Fold a circular filter paper into a cone and place it inside the funnel over a 50 mL cylinder.
- Pour the cooled liquid through the filter paper to trap cloudy tablet filler bits.
- Rinse the beaker with 10 mL of distilled water. Pour that rinse through the filter paper too.
- Add distilled water until the liquid level in the cylinder reaches exactly the 50 mL mark.
- Pour this clear 50 mL liquid into a clean, dry 100 mL beaker labelled 'Tablet Extract'.
- The funnel stem rests securely inside the 50 mL cylinder.
- Liquid is cool to the touch.
- Filter paper is moistened with a drop of water so it sticks to the funnel.
Careful: If you pour too fast, the filter cone can overflow and let cloudy solids into the clean liquid. Pour slowly down the glass rod. Keep the liquid level below the paper rim.

Step 5 of 9
Prepare the five standard test tubes
- Label five clean test tubes 1, 2, 3, 4, and 5 (blank) in the rack.
- To EVERY tube (1 to 5), add: 1.0 mL Solution B, 1.0 mL Solution C, and 1.0 mL Solution D.
- Add 20 mg/L Iron Solution A using a clean pipet: 1.0 mL to Tube 1, 2.0 mL to Tube 2, 3.0 mL to Tube 3, 4.0 mL to Tube 4, and 0 mL to Tube 5.
- Add distilled water to bring every tube to 10.0 mL total volume (see table).
- Mix each tube fully with a clean glass rod. Watch the orange-red colours develop!
- Keep droppers and pipets dedicated to their own reagent bottles.
- Tubes are held securely upright in the rack.
- Wear your safety goggles and gloves.
Careful: If you swap pipets, you contaminate stock bottles and ruin the standard concentrations. Check bottle labels twice before you draw liquid into each pipet.
4 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 12, Chemistry, chapter 5: Coordination Compounds
- Related Level AS & A Level, Chemistry, chapter 24: Transition elements
Versions and what each needs
- How much iron is in your vitamin? (colorimeter)
Chemistry with Vernier, 85 min, Based on a Vernier lab
Needs: Go Direct Colorimeter - How much iron is in your vitamin? (spectrophotometer)
Chemistry with Vernier, 80 min, Based on a Vernier lab
Needs: Go Direct SpectroVis Plus Spectrophotometer
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.