Experiments › Biology
How much oxygen do you breathe?
Oxygen Extraction
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Do your lungs use up all the oxygen in every breath?
Show the answer
Fresh air is about 21% oxygen. Your lungs only take a small slice of that with each breath. Today you will trap your breath and measure exactly how much your body takes.

Introduction
How Much Oxygen Do You Breathe?
Every minute, your lungs pull in room air and push out exhaled gas. You might think your body absorbs all the oxygen inside your lungs in one gulp. But exhaled air still contains plenty of oxygen! In this experiment, you will breathe into a sealed bag and watch an oxygen sensor track the gas levels in real time. You will see exactly how much oxygen your lungs extract breath by breath.
Driving question: How much oxygen does your body actually take from a single breath of air?
What you will learn
Goals for this investigation
- I can measure the drop in oxygen level after each breath.
- I can explain how gas exchange works in the lungs.
- I can calculate how much available oxygen is extracted per breath.
- I can assemble the sensor and bag safely using my own clean mouthpiece.
- I can connect oxygen extraction to high altitudes and spacecraft.
Why it matters: Doctors evaluate lung health by measuring how well lungs transfer oxygen. Astronauts and submarine crews rely on these exact measurements to keep cabin air breathable.
Safety first
Rules for safe breathing tests
- Each student must use their OWN clean disposable mouthpiece. Never share mouthpieces.
- Sit in a sturdy chair when you do the breath steps. Never stand.
- If you feel light-headed or dizzy at any moment, stop immediately and breathe normal room air.
- Students with asthma or respiratory conditions should act as the data recorder rather than the breathing subject.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Handle the utility clamp carefully so the sensor does not slip or drop.
What you need
- Go Direct O2 Gas Sensor1
- ring stand1
- utility clamp1
- resealable plastic bag1 gallon size per student
- Spirometer mouthpieces / filters (consumable)1 per student
- rubber band1 or 2
- roll of tape1 roll
- Tablet running Graphical Analysis1 per group

Step 1 of 6
Clamp the sensor to the ring stand
- Attach the utility clamp securely to the vertical rod of the ring stand.
- Gently clamp the upper body of the Go Direct O2 Gas Sensor so the sensor points straight down.
- Tighten the clamp thumbscrew firmly by hand. Do not over-tighten.
- The ring stand sits flat on a level bench.
- The clamp jaws grip the sensor body, not the buttons.
Careful: Sensor can slip out of a loose clamp and hit the table. Hold the sensor with one hand. Tighten the thumbscrew with your other hand.

Step 2 of 6
Fit and seal the plastic bag to the sensor
- Cut a small round hole, about 25 mm wide, in the top corner of your clean plastic bag.
- Feed the cylindrical shaft of the O2 sensor through the hole into the bag.
- Wrap clear tape tightly around the bag and sensor neck to form an airtight seal.
- Cut the hole carefully with round-tip scissors.
- The hole is just large enough to fit the sensor shaft.
Careful: Air leaks at the taped neck allow room air into the bag and spoil your readings. Wrap several layers of clear tape snugly around the plastic bag and sensor shaft.

Step 3 of 6
Attach the cardboard mouthpiece
- Insert your clean cardboard mouthpiece into the opposite corner hole of the plastic bag.
- Wrap a tight rubber band around the bag neck over the tube to hold it in place.
- Make sure that the tube hole is clear. Make sure that the rubber band forms an airtight hold.
- Use only your own new mouthpiece.
- Do not place the tube in your mouth yet.
Careful: Rubber band can snap if overstretched. Wrap the rubber band two or three times firmly. Do not tighten it too much.

Step 4 of 6
Connect sensor and check baseline oxygen
- Turn on your Go Direct O2 Gas Sensor. Open Graphical Analysis on your tablet.
- Connect with Bluetooth. The live reading must show 20% to 22% oxygen.
- Gently squeeze old air out of the bag until it is mostly flat before you start.
- Sensor LED blinks green when paired.
- Sensor has warmed up for at least 2 minutes.
Careful: Cold sensor or trapped stale breath reads lower than 20%. If the reading is below 20%, squeeze the bag empty and let fresh room air enter, then check again.

Step 5 of 6
Perform the timed breathing protocol
- Tap Collect and breathe normal room air during the first 10 seconds.
- At 10 seconds, exhale completely through the tube into the bag. Keep your mouth on the tube.
- Wait 10 seconds. Inhale the air back out of the bag. Repeat every 10 seconds until 80 s.
- Subject is seated in a chair.
- The partner watches the tablet timer and calls out 10-second intervals.
- The subject knows to release the tube immediately if they feel light-headed.
- The test subject sits comfortably in a chair with all air squeezed out of the bag.
- Remember: stop immediately if you feel dizzy or uncomfortable!
Careful: When you breathe the air again, oxygen decreases and carbon dioxide increases. This can cause light-headedness. Stop the test immediately if you feel any dizziness. Remove your mouth from the tube. Breathe normal room air.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 11, Biology, chapter 14: Breathing and Exchange of Gases
- Direct Class 7, Chemistry, chapter 4: Pure Substance Mixture and Compound
- Related Class 7, Chemistry, chapter 9: General Discussion of Constituents of Air
- Direct Level AS & A Level, Biology, chapter 9: Gas exchange
Versions and what each needs
- How much oxygen do you breathe?
Human Physiology, 50 min, Based on a Vernier lab
Needs: Go Direct O2 Gas Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.