Experiments › Biology

How much protein is in milk?

Protein Bradford Assay

Grades 7-8Biology1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

A tall clear glass of fresh white milk beside a glass bottle on a sunny breakfast table

Wonder

How do food scientists prove how much muscle-building protein is inside milk?

Show the answer

A special dye changes from brown to bright blue when it binds to protein. Scientists call this measuring protein concentration, and today you will measure the protein in milk.

Two test tubes showing a brown dye solution next to a bright blue protein dye solution

Introduction

The Blue Protein Clue

Every bottle of milk lists protein on the nutrition label. But milk is pure white. How can scientists measure protein without seeing it? Biologists use a special dye called Bradford reagent. In water, this dye looks reddish-brown. When it touches protein molecules, it latches on and turns bright blue! The more protein there is, the deeper blue it turns. Today, you will build a standard colour line and test milk like a real food biochemist.

Driving question: Can we use light and a colour-changing dye to measure the exact protein inside milk?

What you will learn

Today you will find out

  • I can explain why the dye turns blue when protein is present.
  • I can use a spectrophotometer to build a standard line.
  • I can find the unknown protein amount in milk using my graph.
  • I can handle micropipets and cuvettes safely without spilling dye.
  • I can explain how food scientists test protein on nutrition labels.

Why it matters: Dairy companies, medical labs, and athletes rely on accurate protein testing every day. Today you run the very same biochemical test.

Safety first

Lab Safety Rules

  • Wear chemical splash goggles and protective gloves at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Bradford dye reagent contains dilute phosphoric acid. It can irritate eyes and stain clothes.
  • Never taste or drink the milk or any lab solutions.
  • Handle micropipets smoothly. Never let liquids get sucked into the pipet barrel.
  • Keep all liquids 30 cm away from the laptop or tablet.
  • Wash your hands fully with soap and warm water when you finish.

What you need

  • Go Direct SpectroVis Plus Spectrophotometer1 per station · teacher
  • Plastic cuvette (4 clear sides)8 cuvettes with caps
  • micropipette2 (20-200 uL and 100-1000 uL)
  • micropipette tips in rack1 box each (200 uL and 1000 uL)
  • 15 mL centrifuge tube2 tubes (labelled PB and BR) · teacher
  • microcentrifuge tubes7 tubes (BGG standards)
  • bottle of cow milk1 mL nonfat milk in a microtube
  • Lint-free tissue box1 box
  • protective lab gloves1 pair per student
Adult pouring Bradford reagent into a 15 mL centrifuge tube

Step 1 of 9 Teacher does this

Dispense buffer and Bradford dye

  1. An adult adds 3 mL of phosphate buffered saline (PBS) to a 15 mL tube labeled 'PB'.
  2. The adult adds 12 mL of Bradford dye reagent to a second 15 mL tube labeled 'BR'.
  3. Place both tubes upright in your rack.
Stop and check
  • The adult wears purple nitrile gloves and safety goggles.
  • Work area is clean and dry.
  • Students stand one step back from reagent bottles.
  • Notice the Bradford dye is reddish-brown in the tube.

Careful: Bradford reagent contains dilute acid that can irritate eyes and stain surfaces. Pour slowly over a spill tray. Cap reagent stock bottles immediately.

Student pipetting 20 microlitres of milk into a microtube containing buffer

Step 2 of 9

Dilute the milk sample 50 times

  1. Use a fresh tip to pipet 980 uL of PBS into tube M.
  2. Use a new tip to add 20 uL of nonfat milk.
  3. Close the microtube cap tightly. Flick the tube five times to mix fully.
Stop and check
  • Wear light blue gloves and goggles.
  • Check the micropipet dials: 980 uL for buffer, 20 uL for milk.
  • Use a fresh tip for each liquid.
  • Write 'M' on the lid of an empty 1.5 mL microtube with a marker.
  • Set the large micropipet to 980 microlitres and the small micropipet to 20 microlitres.

Careful: If you use the wrong tip or dial setting, it will ruin the 50-times dilution ratio. Double check the dial window numbers before you push the plunger.

A student pipetting 1 mL of brown Bradford dye into a row of square cuvettes

Step 3 of 9

Fill cuvettes with Bradford dye

  1. Line up nine clean cuvettes in your cuvette rack.
  2. Label their caps: B, 2.0, 1.5, 1.0, 0.75, 0.5, 0.25, 0.125, and M (use the side for M).
  3. Use the 1000 uL micropipet to add exactly 1.0 mL of Bradford dye into each cuvette.
Stop and check
  • All cuvettes stand securely in the rack.
  • Check that the pipet is set to 1000 uL.
  • Do not touch the optical clear faces of the cuvettes.
  • Confirm each cuvette holds identical amounts of reddish-brown dye.

Careful: Too much liquid in a cuvette can cause leaks inside the sensor optical compartment. Dispense smoothly along the inner wall. Fill each cuvette to exactly 1 mL.

Row of cuvettes shifting in colour from brown to deep blue

Step 4 of 9

Add standards and watch the blue appear

  1. Add 20 uL of PBS buffer to cuvette B (blank). Put the cap on the cuvette. Invert the cuvette gently 3 times.
  2. Add 20 uL from the correct protein standard tube to cuvettes 2.0 through 0.125.
  3. Add 20 uL from diluted milk tube M to cuvette M. Put the cap on the cuvette. Invert the cuvette 3 times.
Stop and check
  • Small micropipet is set to 20 uL.
  • Always change the tip between different standards.
  • Cap each cuvette securely before you turn it upside down.
  • Change pipet tips every time between different protein standards.
  • Watch tubes with high protein quickly shift from brown to vivid blue.

Careful: If you reuse tips, protein transfers backwards and ruins the standard ladder. Eject the tip into waste after each single transfer. Press caps tight before you invert the cuvette.

Go Direct SpectroVis Plus beside a tablet showing Vernier Spectral Analysis

Step 5 of 9 Teacher does this

Connect the spectrophotometer

  1. An adult turns on the Go Direct SpectroVis Plus and connects it to the tablet by Bluetooth.
  2. Open the Vernier Spectral Analysis app.
  3. Select 'Absorbance vs. Concentration' from the experiment menu.
Stop and check
  • Sensor power LED is on.
  • Table around the sensor is dry.
  • Keep all liquids 30 cm away from the tablet.
  • Wait 5 minutes for the internal lamp to warm up and stabilise.

Careful: Liquid splashed into the open cuvette well can destroy the internal optics and electronics. Never pipet liquids directly above the sensor. Keep the sensor on dry bench space.

4 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 6, Science, chapter 3: Mindful Eating: A Path to a Healthy Body
  • Direct Class 12, Biology, chapter 10: Biotechnology and its Applications
ICSE (CISCE)
  • Related Class 9, Biology, chapter 10: Human Nutrition
Cambridge AS & A Level
  • Related Level AS & A Level, Biology, chapter 2: Biological molecules
IB Diploma
  • Direct Level DP, Sports, Exercise and Health Science, chapter 3: Energy Systems
  • Direct Level DP, Biology, chapter B1.2: Proteins

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.