Experiments › Chemistry
How much room does gas need?
Mol Vol
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
If you trap invisible gas from a bubbling metal, how much room does it take?
Show the answer
Every bunch of gas particles takes up a predictable amount of space. Today you trap gas to find out!

Introduction
The Secret Size of Invisible Gas
When bubbles fizz or air fills a balloon, invisible gas particles spread out and push against everything around them. If you trap that gas, you can measure how hard it pushes. Today, you will trap gas from a chemical reaction to find the molar volume of a gas.
Driving question: How much space does an invisible gas actually take up?
What you will learn
Today you will find out
- I can explain how a chemical reaction makes gas that builds up pressure.
- I can record the rise in gas pressure as metal reacts in a sealed flask.
- I can find the volume of a gas package from pressure and temperature readings.
- I can connect airtight gas tubing and follow acid safety rules.
- I can name real-world machines that rely on rapid gas production.
Why it matters: Engineers who design car airbags, scuba gear, and rocket fuel tanks must know the exact volume gas occupies.
Safety first
Safety Rules for Today's Lab
- Wear splash goggles, protective gloves, and a lab apron at all times.
- Hydrochloric acid (1.0 M) can damage skin and eyes: handle with extreme care.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Never open the two-way valve while the flask holds pressure.
- Keep open flames and sparks away from the reaction area because hydrogen gas is flammable.
- If any acid spills on hands or tables, tell your teacher immediately and rinse with lots of water.
What you need
- Go Direct Gas Pressure Sensor1
- Go Direct Temperature Probe1
- Stir Station1
- Electrode Support1
- 125 mL Erlenmeyer flask1
- 1 L beaker1
- Two-hole rubber stopper with valve and tubing1 assembly
- plastic syringe1 (20 mL) · teacher
- metal ribbon strip1 strip (0.012 g)
- 0.1 M Hydrochloric acid solution10 mL (1.0 M HCl) · teacher
- Splash goggles and nitrile gloves1 per person

Step 1 of 8
Find your flask volume
- Fill the 125 mL Erlenmeyer flask completely to the brim with tap water.
- Push the rubber stopper into the neck to displace excess water, then remove the stopper.
- Pour the rest of the water into a graduated cylinder. Record the true volume. Dry the flask.
- The flask and cylinder are clean glass.
- Work over a lab tray or sink to catch water that overflows.
Careful: Water might spill onto books or electronics on the desk. Pour slowly over a sink or tray. Keep tablets 30 cm away.

Step 2 of 8
Add the magnesium ribbon
- Get a pre-cut strip of magnesium ribbon from your teacher.
- Record the exact mass to three decimal places (0.001 g) in your notebook.
- Drop the shiny magnesium strip into the clean, dry 125 mL Erlenmeyer flask.
- The flask interior is completely dry.
- Hands are gloved.
- Confirm its mass on an analytical balance (it should be between 0.010 g and 0.015 g).
Careful: Moisture inside the flask can react with magnesium prematurely. Wipe the flask dry with a paper towel before you drop in the ribbon.

Step 3 of 8
Prepare the water bath
- Place the large 1000 mL beaker on the base of the Stir Station.
- Fill the beaker with room-temperature tap water up to about 800 mL.
- Insert the Go Direct Temperature Probe into the clamp so its tip rests in the water bath.
- The Stir Station cord is tucked away safely.
- The beaker sits flat and steady on the platform.
- Slide the Electrode Support clamp onto the metal support rod.
Careful: A bump to the beaker can cause a water spill. Position the Stir Station at least 15 cm from the bench edge.

Step 4 of 8
Seal flask and connect sensor
- Twist the white rubber stopper firmly into the neck of the 125 mL flask to make a gas-tight seal.
- Connect the clear tube from the stopper to the Go Direct Gas Pressure Sensor with a half-turn.
- Lower the flask into the water bath until the water covers the gas space.
- The stopper is twisted in snugly.
- The two-way valve handle is turned crosswise (closed).
- Turn the blue handle of the two-way valve perpendicular to the stem so the valve is CLOSED.
Careful: A loose stopper lets hydrogen leak and gives false pressure data. Press and twist the stopper firmly into the neck so it cannot slip out.

Step 5 of 8 Teacher does this
Load the acid syringe
- The teacher draws exactly 5.0 mL of 1.0 M hydrochloric acid into the 20 mL syringe.
- Wipe any drop from the outside tip with a damp paper towel.
- Thread the syringe tip firmly onto the top connector of the two-way valve.
- The teacher wears purple gloves and splash goggles.
- Syringe is loaded with exactly 5.0 mL of 1.0 M HCl.
- The two-way valve is completely closed.
- Students check that the valve remains CLOSED so no acid enters yet.
Careful: 1.0 M hydrochloric acid causes severe skin and eye damage if spilled or splashed. Only the teacher dispenses and threads the acid syringe. Students stay 30 cm back.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 10, Science, chapter 1: Chemical Reactions and Equations
- Related Class 10, Science, chapter 2: Acids, Bases and Salts
- Related Class 10, Science, chapter 3: Metals and Non-metals
- Related Class 11, Chemistry, chapter 1: Some Basic Concepts of Chemistry
- Related Class 11, Chemistry, chapter 3: Classification of Elements and Periodicity in Properties
- Direct Class 9, Chemistry, chapter 6: Study of the First Element Hydrogen
- Direct Level DP, Chemistry, chapter Structure 1.5: Ideal gases
Versions and what each needs
- How much room does gas need?
Advanced Chemistry, 60 min, Based on a Vernier lab
Needs: Go Direct Gas Pressure Sensor, Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.