Experiments › Chemistry
How much vitamin C is in your juice?
Vitamin C in Orange Juice
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can a sensor read the vitamins inside your morning juice?
Show the answer
Vitamin C fights oxidants by giving away tiny electrical charges. By feeding it iodine drops and measuring voltage, you will catch the exact moment every vitamin molecule is used up!

Introduction
The Vitamin C Mystery
Orange juice labels boast that one glass gives you 80% of your daily vitamin C. But how do food scientists prove that claim? You cannot see vitamins with your eyes. In this lab, we use a chemical reaction. Vitamin C swallows iodine molecules instantly by passing tiny electrical charges. We will use a sensitive voltage probe to find the exact drop where all vitamin C runs out.
Driving question: How can an electrical probe reveal the hidden vitamin C inside a glass of juice?
What you will learn
Today you will find out
- I can explain how vitamin C reacts with iodine.
- I can find the steep jump on a voltage graph.
- I can figure out the vitamin C amount from buret volume.
- I can control a buret tap and use the ORP sensor correctly.
- I can compare lab measurements with juice carton nutrition facts.
Why it matters: Food companies, hospital labs, and nutritionists test foods daily to make sure consumers get real nutrients.
Safety first
Lab Rules for Chemical Titration
- Wear chemical splash goggles, lab aprons, and nitrile gloves at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- The teacher prepares the iodine solution with concentrated sulfuric acid. Students never touch strong acid.
- Iodine solution can stain skin and clothes brown. Rinse spills immediately with cold water.
- Never taste or drink orange juice once it enters the science lab. Lab glassware is never for food.
- Handle the long glass buret with two hands so you do not break the tip.
- Keep tablet electronics at least 30 cm away from all liquid beakers.
What you need
- Go Direct ORP Sensor1
- Vernier Stir Station and stir bar1
- Electrode Support1
- buret1 (25 mL)
- utility clamp1
- 250 mL beaker2
- 50 mL graduated cylinder1
- clear solution in a reagent bottle35 mL (0.0075 M iodine stock) · teacher
- yellow or orange liquid in a reagent bottle35 mL orange juice
- Distilled water wash bottle1
- Plastic Beral pipets2
- Tablet running Graphical Analysis1

Step 1 of 7
Prepare the orange juice sample
- Use the 50 mL graduated cylinder to measure exactly 30 mL of orange juice.
- Pour the juice into a clean 250 mL beaker.
- Rinse the cylinder with distilled water. Measure 30 mL of distilled water. Add it to the beaker.
- Swirl gently to mix the juice and water together.
- You wear goggles and nitrile gloves.
- Beaker is placed safely in the centre of the bench.
- Juice is at room temperature.
Careful: Spilled juice or an incorrect cylinder reading gives an inaccurate start volume. Read the liquid meniscus at eye level. Pour steadily down the side of the beaker.

Step 2 of 7 Teacher does this
Adult provides the iodine titrant
- An adult pours about 35 mL of 0.0075 M iodine solution into your second 250 mL beaker.
- Sulfuric acid keeps the triiodide ion stable in this iodine solution.
- Label this second beaker 'Iodine Titrant'. Keep it behind the buret stand.
- Adult wears chemical splash goggles and purple gloves.
- Students stand one step back from the dispenser bottle.
- A roll of paper towels is nearby.
Careful: The solution contains dilute sulfuric acid and iodine, which can irritate skin or stain clothes. Adult pours the solution. If drops touch skin, wash with cold water from the tap for 2 minutes.

Step 3 of 7 Teacher does this
Fill and prime the buret
- Make sure the buret stopcock at the bottom is horizontal (closed).
- Under adult supervision, place a small plastic funnel in the top of the 25 mL buret.
- Slowly pour iodine solution into the buret until it reaches above the 0 mL mark.
- Place a waste cup beneath the tip. Open the stopcock briefly to fill the tip with liquid. Make sure no air bubbles remain.
- Adjust the level so the liquid surface sits exactly on or below 0.0 mL.
- The buret stopcock is closed tight before you pour.
- Buret is clamped firmly and upright.
- Waste cup is placed under the tip.
Careful: If you pour too fast, liquid can overflow the buret funnel or trap air in the delivery tip. Pour at eye level with a funnel. Tap the tip gently while liquid drains into waste to remove air.

Step 4 of 7
Assemble the titration station
- Place your juice beaker on the Stir Station plate. Drop the white magnetic stir bar inside.
- Attach the Electrode Support to the upright rod and slide the Go Direct ORP Sensor into it.
- Turn on the Stir Station and slowly turn the speed knob until the juice stirs gently.
- Stir Station is plugged in or switched on.
- Electrode Support screws are tightened snugly.
- ORP sensor storage bottle is unscrewed and stored safely.
- Stir Station is placed flat on the lab bench.
- Sensor tip dips about 2 cm into the juice and does not touch the bottom or stir bar.
Careful: The magnetic stir bar can strike and crack the glass electrode bulb as it turns. Position the sensor towards the side wall of the beaker, well away from the center.

Step 5 of 7
Record the starting point (0.0 mL)
- Position the buret tip directly over the beaker mouth. Do not touch the glass sides.
- Tap 'Collect' in Graphical Analysis to begin.
- Read the start level on your buret. If it sits on 0.0 mL, write down 0.0.
- Before you open the buret stopcock, tap 'Keep'. Type '0.0' for Volume. Tap 'Keep Point'.
- Your first dot appears on the screen. It shows the start voltage of untouched juice.
- The stir bar rotates smoothly on speed 3.
- The buret tip is centered over the beaker mouth.
- The tablet shows live potential readings.
Careful: If you add liquid before you save the zero point, you ruin the baseline reading. Always store the 0.0 mL point before you open the stopcock.
2 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 11, Chemistry, chapter 1: Redox Reactions
- Related Level AS & A Level, Chemistry, chapter 7: Redox reactions
Versions and what each needs
- How much vitamin C is in your juice?
Food Chemistry, 60 min, Based on a Vernier lab
Needs: Go Direct ORP Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.