Experiments › Biology
How nerves turn off signals
Neurotransmitters and Enzyme Action
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
What stops your muscles from contracting forever once a nerve fires?
Show the answer
Nerves release chemical messengers, but super-fast cleanup enzymes chop them up in milliseconds. Today you will measure this cleanup enzyme in action.

Introduction
How Nerves Turn Off Signals
When you decide to move a muscle, your brain sends a command. Nerves squirt a tiny chemical messenger onto muscle cells. But what happens next? If the chemical stayed there, your muscle would stay cramped tight! Your body uses a speedy enzyme to chop up the messenger so muscles relax. Today, you will watch this cleanup enzyme work and measure its speed using light.
Driving question: How does your body switch off a nerve signal once the job is done?
What you will learn
Today you will find out
- I can explain how nerve signals start and stop.
- I can track how fast an enzyme reaction turns yellow.
- I can tell which cell part has the most cleanup enzyme.
- I can show how a medicine slows down an enzyme.
- I can work safely with biological solutions and cuvettes.
Why it matters: Nerve messengers control your heartbeat, breathing, and memory. Understanding them helps doctors treat illnesses and develop life-saving medicines.
Safety first
Laboratory Safety Rules
- Wear safety goggles, lab aprons, and nitrile gloves at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Never taste or touch heart extracts and test chemicals with bare skin.
- Look for the ADULT NEEDED badge on teacher-handled chemical preparation steps.
- Keep all biological tubes in crushed ice when you do not use them.
- Put all cuvette mixtures into the chemical waste bucket.
- Wash your hands fully with soap and warm water when you finish.
What you need
- Go Direct Colorimeter1
- Plastic cuvette (4 clear sides)4
- 0.1 M phosphate buffer, pH 7.910 mL
- Heart tissue fractions on ice (W, S, N)1 tube each · teacher
- 10 mM DNTB and 100 mM ACTHi solutions2 mL each · teacher
- 20–200 µL micropipette with tips1
- Lint-free tissue box1 box

Step 1 of 8
Connect and pair the Colorimeter
- Press the power button to switch on your Go Direct Colorimeter.
- Open Graphical Analysis on your tablet. Tap Sensor Data Collection.
- Select your colorimeter from the Bluetooth list.
- Tablet Bluetooth is turned on.
- Sensor has sufficient battery charge.
- Make sure that the status light on the sensor turns green.
Careful: The sensor can connect to an adjacent group's tablet. Match the serial number printed on your sensor label.

Step 2 of 8
Label your four test cuvettes
- Take four clean plastic cuvettes and place them in the rack.
- Use a fine permanent marker to write on the top edge of each cap only.
- Label them W (Whole extract), S (Supernatant), N (Nuclear fraction), and C (Control).
- Cuvettes are clean, dry, and free of scratches.
- Cuvettes sit securely upright in the rack.
- Never write on the clear plastic sides of the cuvettes.
Careful: Ink on the clear sides blocks light and ruins your data. Write only on the small plastic cap tops.

Step 3 of 8
Add buffer to all four cuvettes
- Use a clean transfer pipette or graduated cylinder to measure phosphate buffer.
- Add exactly 2.0 mL of phosphate buffer into each of the four cuvettes (W, S, N, and C).
- Buffer keeps the pH stable at 7.9 so the heart enzymes stay happy and active.
- Phosphate buffer is at room temperature.
- Keep electronics at least 30 cm away from liquids.
Careful: Too much liquid in the cuvette can cause spills inside the sensor. Add only 2.0 mL so the liquid fills about two-thirds of the cuvette.

Step 4 of 8 Teacher does this
Prepare and calibrate with a blank
- Teacher adds 100 µL of nuclear fraction, 100 µL of DTNB, and 100 µL of distilled water to Cuvette C (Control).
- Cap the cuvette, invert gently three times, and wipe the clear sides with a tissue.
- Put the cuvette in the colorimeter. Select 430 nm (Blue). Press the CAL button until the LED stops.
- The teacher uses the micropipette for DTNB and nuclear fraction.
- Goggles and gloves worn by all participants.
- Use Cuvette C (Control) as your blank. Point the clear sides toward the light path.
Careful: Calibration at the wrong wavelength gives near-zero enzyme response. Set the wavelength arrows to 430 nm blue before you press CAL.

Step 5 of 8 Teacher does this
Test Run 1: Whole heart extract
- Teacher quickly adds: 100 µL whole extract (W), 100 µL DTNB, and 100 µL ACTHi substrate.
- Cap immediately, invert three times, wipe with tissue, and place inside the colorimeter.
- Close the lid. Press Collect for 5 minutes. Select Store Run from experiment options.
- Cuvette cap is within arm's reach.
- The colorimeter lid is open and ready.
- Graphical Analysis is ready to tap Collect.
- Take Cuvette W (which already holds 2 mL of buffer).
Careful: If you wait too long after you add ACTHi, you lose the first part of the reaction curve. Cap, invert three times, insert, and press Collect within 15 seconds.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Level DP, Biology, chapter C1.1: Enzymes and metabolism
- Direct Level DP, Biology, chapter C2.1: Chemical signalling
Versions and what each needs
- How nerves turn off signals
Advanced Biology, 60 min, Based on a Vernier lab
Needs: Go Direct SpectroVis Plus Spectrophotometer, Go Direct Colorimeter
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.