Experiments › Biology (Human Physiology)
How powerful are your lungs?
Lung Function
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Ever wonder how much air your chest can blast out in one second?
Show the answer
Your lungs hold litres of air and can launch it out faster than a gale-force wind. Today you will map your airflow loop with a digital spirometer.

Introduction
How Powerful Are Your Lungs?
When you blow out birthday candles or sprint down a sports pitch, your lungs push litres of air out through your windpipe. But does air leave at a steady speed, or does it blast out fast and then slow down? Today, you will use a hand-held digital spirometer to measure the speed and volume of your breath. By tracking airflow against total air volume, you will create a live flow-volume loop of your own lungs.
Driving question: How fast and how much air can your lungs blast out in a single breath?
What you will learn
Today you will find out
- I can collect a smooth flow-volume loop using a spirometer.
- I can read the highest airflow and total air volume from my lung graph.
- I can calculate what fraction of my total breath leaves in the first second.
- I can explain how airway changes alter the breathing loop shape.
- I can explain why athletes and doctors measure lung airflow.
Why it matters: Sports scientists tune athlete stamina, doctors check asthma recovery, and singers build breath control using spirometry graphs.
Safety first
Hygiene and Breathing Rules
- Purple gloves = teacher does it. Blue gloves = you do it.
- Every student must use their OWN new bacterial filter and mouthpiece. Never share mouthpieces.
- Used mouthpieces and filters must go directly into the trash bin after your turn.
- Do not volunteer if you currently have a cold, cough, asthma flare-up, or flu.
- Sit down while you do the breath test. Air that you blast out while you stand can cause dizziness.
- Stop immediately if you feel lightheaded, faint, or uncomfortable.
- This activity is for science study only. Do not use it to diagnose medical conditions.
What you need
- Go Direct Spirometer1 per group
- Spirometer mouthpieces / filters (consumable)1 filter per subject
- Disposable Mouthpieces for Spirometer1 mouthpiece per subject
- nose clip1 per subject
- Tablet running Graphical Analysis1 per group
- waste bucket1 per classroom

Step 1 of 9
Connect the Spirometer
- Push the power button to turn on your Go Direct Spirometer.
- Open Graphical Analysis on your device. Tap Sensor Data Collection.
- Select your spirometer from the list of wireless sensors to connect.
- Tablet Bluetooth is enabled.
- Spirometer battery is charged (LED flashes green).
Careful: Sensor pairs to another group's device nearby. Match the sensor ID printed on the back label with the name in the app.

Step 2 of 9
Set Advanced Polarity
- In Graphical Analysis, tap the sensor information icon (i) next to your connected spirometer.
- Tap Advanced. Change 'Volume inspiratory polarity' to Negative so inhalation plots below the axis.
- Leave all other settings at default and tap Save.
- Device Information menu is visible.
- Sensor is securely connected.
Careful: If volume polarity stays positive, exhalation and inhalation overlap awkwardly on the graph. Make sure that you set Volume inspiratory polarity to Negative before you close.

Step 3 of 9
Configure Auto-Triggering
- Tap Mode in Graphical Analysis to open Data Collection Settings.
- Switch Start Collection from manual to Trigger event when Flow Rate increases across 0.1 L/s.
- Set 10 points collected before trigger. Tap Done.
- Data Collection Settings window is open.
- Trigger threshold is typed as 0.1 L/s.
Careful: Without auto-trigger, data collection starts before you blow. This misses the start of the blast. Make sure that you turn on the trigger at 0.1 L/s.

Step 4 of 9
Set Up Graph and Table View
- Tap View and choose Graph and Table.
- Tap the x-axis label on the graph and choose Volume.
- Graph axes show Flow Rate (L/s) on y and Volume (L) on x.
- Data table is visible beside or below the graph.
- The vertical y-axis should display Flow Rate.
Careful: If x-axis is Time instead of Volume, you will see a wave instead of a flow-volume loop. Tap the x-axis label. Tap Volume.

Step 5 of 9
Attach Filter and Mouthpiece
- Attach the wider side of a clean bacterial filter onto the 'Inlet' side of the spirometer.
- Push a disposable cardboard mouthpiece firmly onto the outer end of the filter.
- Remember: every student must use their own fresh filter and mouthpiece.
- The bacterial filter is clean and brand new.
- The cardboard mouthpiece is fresh from the box.
- The filter is firmly seated into the Inlet port.
Careful: If you share mouthpieces or filters, you spread viruses and bacteria. Only use your own mouthpiece and filter. Throw them away after your test.
4 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Level DP, Biology, chapter B3.3: Muscle and motility
Versions and what each needs
- How powerful are your lungs?
Human Physiology Vol 2, 60 min, Based on a Vernier lab
Needs: Go Direct Spirometer
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.