Experiments › Earth Science

How salty is the sea?

Salinity of Ocean Water

Grades 7-8Earth Science2 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

A sparkling ocean wave crashing onto sandy rocks with salt crystals glistening

Wonder

Why can you float effortlessly in the Dead Sea but sink in a swimming pool?

Show the answer

The Dead Sea is nearly seven times saltier than ordinary ocean water. Strong sun bakes away the water, leaving all the salt behind. Today you will measure how sun and rivers control ocean saltiness.

A wide aerial view of a river mouth pouring fresh water into a darker blue ocean

Introduction

Why Is the Sea Salty?

Over seventy percent of Earth is covered by seawater, yet humans cannot drink it. Why is the ocean so salty? Rain washes minerals from land into oceans, and undersea volcanoes blast out dissolved salts. In hot areas, the Sun evaporates pure water into the air, leaving all the salt behind. At river mouths, rushing freshwater dilutes the sea. In this lab, you will use a conductivity sensor to track how sunlight and rivers change ocean salinity.

Driving question: Why is ocean water salty, and what causes its saltiness to change?

What you will learn

Today you will find out

  • I can measure the salinity of water using a conductivity probe.
  • I can explain why water evaporation makes saltwater saltier.
  • I can observe and describe how river water dilutes seawater.
  • I can read a graph that shows salinity dropping as freshwater mixes in.
  • I can connect salinity changes to real seas and river mouths on Earth.

Why it matters: Ocean saltiness drives deep ocean currents, shapes marine animal habitats, and controls world climate.

Safety first

Laboratory Safety Rules

  • Wear splash goggles and lab aprons at all times around glassware and liquids.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Keep all water, beakers, and wet pans at least 30 cm away from electrical cords and wall sockets.
  • Desk lamp bulbs get extremely hot during operation. Never touch the bulb or metal shade with bare hands.
  • Never drink any water in the science lab. Do not drink it even if a label says tap water or saltwater.
  • Mop up any floor spills immediately to prevent slip hazards.

What you need

  • Go Direct Conductivity Probe1 per group
  • Tablet running Graphical Analysis1 per group
  • shallow metal pan2 per group
  • desk lamp with light bulb1 per group
  • plastic storage tub2 (one medium, one large)
  • ring stand with clamp1 set per group
  • plastic syringe1 syringe with flexible plastic tubing
  • 400 mL beaker1 per group
  • Distilled water wash bottle1 per group
  • heavy book1 textbook and 1 roll of masking tape
  • tissue wipes1 box per group
Student hand holding conductivity probe upright in a 400 mL beaker filled with clear saltwater

Step 1 of 7

Measure starting salinity of saltwater

  1. Pour 500 mL of prepared Part I saltwater into your clean 400 mL beaker.
  2. Rinse the probe tip with distilled water and blot dry with a soft tissue.
  3. Lower the probe into the saltwater until the liquid covers the oval hole near the tip fully.
  4. Swirl gently once, tap Collect, then tap Keep.
  5. Leave the probe still in the water for 10 seconds while the app averages the salinity.
  6. Record this initial salinity value in your data table.
Stop and check
  • Splash goggles are on.
  • The sensor hole is completely underwater.
  • The tablet is kept dry.

Careful: If the hole near the tip is not fully submerged, air bubbles trap inside and read zero. Lower the probe at least 3 cm into the liquid. Swirl gently to remove bubbles.

Two aluminum pans on bench, one under a glowing desk lamp bulb 10 cm above water, one unlit nearby

Step 2 of 7 Teacher does this

Set up evaporation pans for Day 1

  1. Place two shallow aluminum pans on a level lab bench.
  2. Pour 250 mL of your saltwater into Pan 1 and 250 mL into Pan 2.
  3. Position a desk lamp directly over Pan 1 so the bulb is 10 cm above the water surface.
  4. Place Pan 2 at least 60 cm away from the lamp where no direct light hits it.
  5. Switch on the desk lamp and leave both pans undisturbed overnight.
Stop and check
  • The lamp cord is untangled and away from water.
  • The lamp bulb is exactly 10 cm above the water.
  • The teacher examined the setup.

Careful: The lamp bulb gets extremely hot and can cause burns or melt plastic cords. Keep cords clear of pans. Do not touch the bulb or shade once switched on.

Student pouring remaining water from an aluminum pan into a labeled glass beaker

Step 3 of 7

Day 2: Measure final salinity in both pans

  1. Switch off the desk lamp and slide Pan 1 carefully out from underneath.
  2. Carefully pour the rest of the liquid from Pan 1 into a clean beaker with the label 'Light'.
  3. Pour the liquid from Pan 2 into a second beaker labeled 'No Light'.
  4. Rinse the probe with distilled water and blot dry with a tissue.
  5. Measure the 10-second average salinity of each beaker. Record the values.
  6. Subtract initial salinity from final salinity to calculate each pan's salinity change.
Stop and check
  • The lamp cooled down before you move the pans.
  • Beakers are clearly labeled 'Light' and 'No Light'.
  • Probe is rinsed with distilled water between tests.

Careful: Salt residue on the probe from the concentrated beaker skews data in the unlit beaker. Fully squirt the probe tip with distilled water. Blot it dry between every test.

Medium plastic tub elevated on a book next to a large plastic tub with a probe clamped on a ring stand

Step 4 of 7

Set up the river and ocean model

  1. Place a medium plastic tub on top of a thick textbook. This is your River Tub.
  2. Place a large plastic tub on the table right next to it. This is your Ocean Tub.
  3. Pour 1.0 L of fresh tap water into the River Tub.
  4. Pour 1.0 L of prepared Part II saltwater into the Ocean Tub.
  5. Use a clamp on a ring stand to hold the conductivity probe upright inside the Ocean Tub.
  6. Make sure that the saltwater fully covers the side hole of the probe.
Stop and check
  • The textbook elevates the River Tub steadily.
  • The ring stand is sturdy and will not tip over.
  • The sensor hole is fully submerged.

Careful: An unstable book can slip and spill 1 L of water across the desk. Center the medium tub squarely on the book. Wipe any wet droplets immediately.

Student hand pulling syringe plunger to draw water through tube connecting two tubs

Step 5 of 7

Prime the river siphon tube

  1. Connect a 30 cm clear plastic tube to the tip of a plastic syringe.
  2. Place the open end of the tube underwater in the River Tub.
  3. Pull the syringe plunger back until you draw about 5 mL of water into the syringe.
  4. Keep water in the tube. Place the syringe end underwater in the Ocean Tub.
  5. Attach the tube securely to the rims of both tubs with tape.
  6. Position the conductivity probe so its tip is exactly 5 cm from the tube exit in the Ocean Tub.
Stop and check
  • The tube is completely filled with water (no air bubbles).
  • Both ends stay submerged.
  • The probe is 5 cm from the tube exit.

Careful: If air enters the tube, gravity cannot pull water across and the siphon stops. Keep both ends of the tube completely underwater when you tape them in place.

2 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 6, Science, chapter 9: Methods of Separation in Everyday Life
  • Related Class 8, Science, chapter 11: Chemical Effects of Electric Current
ICSE (CISCE)
  • Related Class 10, Chemistry, chapter 6: Electrolysis
Cambridge AS & A Level
  • Related Level AS & A Level, Biology, chapter 18: Classification, biodiversity and conservation

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.