Experiments › Chemistry
How sour is your soda?
Acidity of Beverages
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does a sweet cold drink still make your teeth feel sensitive?
Show the answer
Even very sweet drinks hide strong acids behind heavy sugar. Today you will catch that hidden acid by neutralizing it drop by drop.

Introduction
How Sour Is Your Soda?
Soft drinks and fruit juices taste sweet, but they are also packed with acids. Lemon-lime soda contains citric acid, while apples contain malic acid. Because these drinks are loaded with sugar, your tongue cannot tell how much acid is hiding inside! In this lab, we will use a Go Direct pH Sensor and a buret to neutralize the acid drop by drop. When all the acid is gone, the pH will jump up sharply. The amount of base we add reveals the hidden acid.
Driving question: Which has more acid: sweet apple juice or fizzy soda?
What you will learn
Today you will find out
- I can explain how a base cancels out an acid.
- I can spot the sudden pH jump on a graph during neutralization.
- I can compare two drinks to see which has more acid.
- I can safely use a buret and protect the glass pH probe.
- I can explain why drink acidity matters for dental health.
Why it matters: Food scientists test drink acidity to balance flavour and prevent bacterial growth without harming your teeth.
Safety first
Scientist Rules for Today
- Wear splash goggles, protective gloves, and a lab apron at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Sodium hydroxide can cause severe chemical burns to skin and eyes.
- Only an adult fills the tall glass buret with sodium hydroxide solution.
- Never taste any lab liquid, even if it comes from a soda bottle or juice carton.
- Spin the magnetic stir bar gently so it does not strike and break the glass sensor bulb.
- Wash your hands fully with water and soap after you clean up.
What you need
- Go Direct pH Sensor1
- Vernier Stir Station and stir bar1
- 50 mL buret and buret clamp1 · teacher
- Electrode Support1
- Tablet running Graphical Analysis1
- 0.10 M Sodium hydroxide solution70 mL · teacher
- 250 mL beaker2
- 25 mL graduated cylinder1
- Flat lemon-lime soda (degassed overnight)30 mL
- Clear apple juice30 mL
- Distilled water wash bottle1
- Splash goggles and nitrile gloves1 set per person

Step 1 of 6 Teacher does this
Adult fills and readies the buret
- An adult clamps the clean 50 mL buret to the Stir Station rod.
- Place a waste beaker below the buret tip.
- The adult pours 0.10 M sodium hydroxide solution into the top with a small funnel.
- Open the stopcock briefly so liquid fills the tip and removes any air bubble. Then adjust the level to 0.00 mL.
- Everyone wears splash goggles and gloves.
- The buret stopcock is closed (horizontal) before you pour.
- A waste beaker is placed directly under the tip.
Careful: Sodium hydroxide can splash if poured above eye level. This can cause serious eye burns. Lower the buret clamp to pour at chest level. Only the adult pours the base.

Step 2 of 6
Measure your first drink sample
- Use the 25 mL graduated cylinder to measure exactly 20.0 mL of flat lemon-lime soda.
- Pour the soda into a clean 250 mL beaker.
- Add 50 mL of distilled water to give enough volume to cover the sensor bulb.
- Gently drop the white magnetic stir bar into the beaker.
- The soda is flat (it does not fizz or foam).
- The beaker is clean and placed on a stable surface.
Careful: If you drop the heavy magnetic stir bar roughly, you can crack the glass beaker base. Tilt the beaker slightly and slide the stir bar gently down the inside wall.

Step 3 of 6
Mount the pH sensor and start stirring
- Place the beaker on the center of the Vernier Stir Station.
- Attach the Go Direct pH Sensor to the Electrode Support clamp.
- Lower the sensor so the drink covers its glass tip safely to the side.
- Turn the stir knob to 3 or 4 so the stir bar spins smoothly. Do not splash liquid or hit the probe.
- Sensor tip is fully submerged in liquid.
- The sensor bulb is at least 1 cm away from the path of the stir bar.
Careful: The stir bar can strike the thin glass sensor bulb and smash it. Position the sensor near the beaker wall, well away from the center vortex.

Step 4 of 6
Record the starting pH before adding base
- Tap Start in Graphical Analysis to begin your titration run.
- Before you touch the buret, look at the live pH reading on the screen.
- Wait 5 seconds for the reading to stabilize.
- Tap Keep. Type '0' for Volume in mL. Tap Keep Point.
- Buret stopcock is closed tight.
- The sensor reading is steady (it does not drift by more than 0.05 pH).
Careful: If you turn the stopcock before you record 0 mL, you ruin the baseline. Keep hands off the buret stopcock until you log your first zero point.

Step 5 of 6
Titrate the flat soda to find its turning point
- Gently turn the buret stopcock to add about 1.0 mL of sodium hydroxide solution.
- Close the tap. Read the exact buret level. Wait for the pH to become steady. Tap Keep. Type the volume.
- Repeat in 1.0 mL steps until the pH reaches about 6.0.
- Between pH 6.0 and 9.0, add base drop by drop (just 2 or 3 drops at a time). Record every point.
- Continue to add 1.0 mL steps after pH 10.0 until you reach about 12 mL total.
- One student controls the buret, another enters numbers into the tablet.
- Goggles are worn snugly over eyes.
Careful: If you open the valve too far, you release a flood of base past the end point. Use two hands: one holds the buret barrel steady while the other pinches and rotates the stopcock gently.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Level AS & A Level, Chemistry, chapter 21: Further aspects of equilibria
- Related Level DP, Chemistry, chapter Reactivity 2.1: How much? The amount of chemical change
Versions and what each needs
- How sour is your soda? (burette)
AP Chemistry, 80 min, Based on a Vernier lab
Needs: Go Direct pH Sensor - How sour is your soda? (drop counter)
AP Chemistry, 55 min, Based on a Vernier lab
Needs: Go Direct Drop Counter, Go Direct pH Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.