Experiments › Physics
How strong is a magnet?
Magnetic Field
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can you draw an invisible magnetic force field without iron filings?
Show the answer
Every magnet is surrounded by an invisible web of magnetic lines. Today you will steer a digital sensor along a bar magnet to map out its hidden shape and direction.

Introduction
Mapping a Magnetic Field
Magnets can push and pull objects without ever touching them. That invisible reach is called a magnetic field. But what does this field look like in the space around a magnet? Where is it strongest, and which way does it push? In this experiment, you will guide a high-tech magnetic probe past a bar magnet centimetre by centimetre. Your tablet will plot a precise map showing how the field curves and flips in space.
Driving question: How does the invisible force field around a magnet change as you travel from one pole to the other?
What you will learn
Today you will find out
- I can measure and record the magnetic field at set positions beside a magnet.
- I can identify where the magnetic field is strongest and where it changes direction.
- I can explain what positive and negative magnetic field readings mean.
- I can explain how invisible magnetic fields protect Earth and help medical scanners work.
Why it matters: Magnetic fields navigate ships, store computer data, guide electric motors, and protect our entire planet from harmful space radiation.
Safety first
Lab Rules for Today
- Handle strong magnets carefully so fingers are not pinched.
- Keep strong magnets at least 30 cm away from credit cards, mechanical watches, and pacemakers.
- Slide the sensor gently; the long wand is precise and can bend if forced.
- Never drop or bang magnets together, as sharp impacts can crack them or weaken their magnetism.
What you need
- Go Direct 3-Axis Magnetic Field Sensor1
- bar magnets1
- ruler1 metric ruler or meter stick
- roll of tape1 roll of masking tape
- Tablet running Graphical Analysis1

Step 1 of 6
Tape the ruler to the bench
- Place the metric ruler flat on the table, away from iron legs or computers.
- Use two strips of tape at the ends to secure the ruler firmly to the tabletop.
- Make sure that the numbers face toward you so you can read every centimetre clearly.
- The bench surface is clear of metal objects.
- The ruler is taped flat and cannot slide.
Careful: If the ruler moves during tests, all position measurements will shift. Press tape down firmly at both ends of the ruler.

Step 2 of 6
Tape the bar magnet beside the ruler
- Place the bar magnet parallel to the ruler, about 2 to 3 cm away from it.
- Align the South (S) pole end of the magnet exactly with the 3 cm mark on the ruler.
- Tape the magnet down firmly so it cannot shift or slide during the experiment.
- The S pole of the magnet is precisely at the 3 cm mark.
- The magnet sits parallel to the edge of the ruler, not angled.
Careful: If the magnet shifts, your graph curve will be distorted. Tape across the middle of the magnet to keep it locked in position.

Step 3 of 6
Connect sensor and configure settings
- Turn on your Go Direct 3-Axis Magnetic Field Sensor. Connect it with Bluetooth in Graphical Analysis.
- Tap Mode at the bottom left. Change it to 'Event Based'.
- Set Event Name to 'Position'. Set Units to 'cm'. Tap Done.
- The sensor LED flashes green (connected).
- Graphical Analysis shows live readings from the X-axis channel.
Careful: If you select Time-based mode, the sensor collects points continuously and does not wait at each centimetre. Make sure you choose Event Based so you can type each position in centimetres.

Step 4 of 6
Record your starting point at 0 cm
- Align the sensor tip dot at the 0 cm mark on the ruler.
- Tap Collect. Wait for the reading on screen to stabilize. Tap Keep.
- Type 0 for the position. Tap Keep Point.
- The sensor dot at the tip is at 0 cm, not the handle.
- The wand is parallel to the ruler and lies flat on the table.
- Hold the sensor wand flat and parallel to the ruler edge.
Careful: If you angle the sensor wand, different field lines pass through the sensor and cause inaccurate readings. Keep the wand flat on the table and parallel to the ruler at all times.

Step 5 of 6
Slide and record every centimetre
- Slide the probe so the tip dot moves to 1 cm.
- When the reading steadies, tap Keep, type 1, and tap Keep Point.
- Repeat in 1 cm steps: 2 cm, 3 cm, 4 cm, all the way to 16 cm (3 cm past the N pole).
- You enter the exact centimetre number at every step.
- The sensor wand stays strictly parallel to the ruler.
- Keep the wand parallel to the ruler.
Careful: If you accidentally bump the taped magnet, you will shift your coordinate frame. Slide the sensor smoothly along the ruler. Do not touch the magnet.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 6, Science, chapter 4: Exploring Magnets
- Related Class 6, Science, chapter 9: Methods of Separation in Everyday Life
- Direct Class 10, Science, chapter 12: Magnetic Effects of Electric Current
- Related Class 12, Physics, chapter 5: Magnetism and Matter
- Direct Class 6, Physics, chapter 11: Natural and Artificial Magnets
- Related Class 6, Physics, chapter 12: Properties and Uses of Magnet
- Direct Class 6, Physics, chapter 13: Magnetic Field and Magnetic Lines of Force
- Related Class 9, Physics, chapter 10: Electricity and Magnetism 2
Versions and what each needs
- How strong is a magnet? (Middle School Science)
Middle School Science, 45 min, Based on a Vernier lab
Needs: Go Direct 3-Axis Magnetic Field Sensor - How strong is a magnet? (Physical Science)
Physical Science, 50 min, Based on a Vernier lab
Needs: Go Direct 3-Axis Magnetic Field Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.