Experiments › Physical Science

How strong is an electromagnet?

Electromagnets

Grades 7-8Physical Science2 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

An iron nail wrapped in insulated copper wire attracting small metal paper clips

Wonder

Can a plain iron nail pick up steel objects using electricity?

Show the answer

When electric current flows through coiled wire, it creates an invisible magnetic field. Wrap it around iron, and you get an electromagnet you can turn on and off!

A large industrial electromagnetic crane lifting scrap metal in a recycling yard

Introduction

Turning Electricity into Magnetism

Normal magnets are always magnetic. But what if you need a magnet that shuts off with a switch? Giant scrapyard cranes lift entire cars using electromagnets, then drop them instantly by cutting the power. In this lab, you will wrap wire around an iron nail and measure its magnetic strength using a magnetic field sensor. Does adding more coils make your magnet stronger?

Driving question: How can you turn a plain iron nail into a magnet that you can turn on and off?

What you will learn

Today you will find out

  • I can build an electromagnet using a wire, an iron nail, and a battery.
  • I can measure magnetic field strength in milliteslas using a sensor.
  • I can describe how adding more wire winds changes the strength of an electromagnet.
  • I can explain how electricity makes a temporary magnet and where it is used.
  • I can handle electrical connections safely so the battery does not overheat.

Why it matters: Electromagnets power doorbells, MRI hospital scanners, electric motors, and high-speed maglev trains.

Safety first

Electrical and Bench Rules

  • Wear safety goggles throughout the experiment. Sharp wire ends can flick upward.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Never hold wire ends to the battery continuously for more than 3 seconds at a time.
  • A direct circuit across a battery creates high current and causes the battery and wire to get hot.
  • Release the wire from the battery immediately after you take each measurement.
  • If a battery feels hot to the touch, disconnect the wire and notify your teacher.
  • Wash your hands with soap and water after you pack away copper wires.

What you need

  • Go Direct 3-Axis Magnetic Field Sensor1 per group
  • Tablet running Graphical Analysis1 per group
  • iron nail1 large nail (7-10 cm)
  • spool of insulated copper wire1 m single-strand wire
  • dry cell battery1 size D cell (1.5 V)
  • roll of tape1 roll of masking tape
  • safety goggles1 pair per student
Sensor taped flat to the bench with two strips of blue tape

Step 1 of 7

Tape the sensor to the table

  1. Lay the Go Direct Magnetic Field Sensor flat on the lab bench.
  2. Place one strip of tape across the handle and one across the wand.
  3. Press the tape firmly so the sensor cannot slide during tests.
Stop and check
  • Table surface is clean and dry.
  • Goggles are on.
  • Leave 15 cm of open space in front of the wand tip.

Careful: The sensor moves between readings. This causes inconsistent distance and angle measurements. Tape both the handle and wand securely so the sensor stays completely motionless.

Tablet screen showing Graphical Analysis mode settings dialog set to Event Based

Step 2 of 7

Connect sensor and set Event Based mode

  1. Open Graphical Analysis on your device. Connect the sensor with Bluetooth.
  2. Tap Mode at the bottom left. Change it to 'Event Based'.
  3. Set Event Name to 'Winds' and leave Units blank. Tap Done.
Stop and check
  • Sensor power LED is on.
  • Bluetooth is enabled on your tablet or computer.

Careful: Wrong collection mode records continuous time instead of individual wind counts. Choose Event Based mode so each point matches a specific number of wire winds.

Pointed end of bare iron nail touching the tip of the taped magnetic sensor

Step 3 of 7

Record zero winds (baseline)

  1. Tap Collect to start data collection.
  2. Place the pointed end of the bare iron nail directly against the sensor tip (Figure 1).
  3. When the reading stabilizes, tap Keep, type 0, and tap Keep Point.
Stop and check
  • No wire touches the nail yet.
  • The battery is kept at least 20 cm away from the sensor.

Careful: A previously magnetized nail gives a falsely high reading at zero winds. If the reading is above 0.1 mT, have your teacher demagnetize the nail again.

Wire taped to battery bottom and wound 3 times tightly around an iron nail

Step 4 of 7

Tape wire to battery and wind 3 turns

  1. Tape one stripped end of the insulated wire firmly to the flat negative bottom of the D battery.
  2. Place the nail on the wire about 10 to 15 cm away from the battery.
  3. Tightly wind the wire around the nail exactly 3 times (Figure 1).
Stop and check
  • The top wire end is loose and does NOT touch the top of the battery yet.
  • The tape on the bottom terminal holds the bare copper securely.
  • Keep the coils clustered close together near the tip of the nail.

Careful: Loose coils slide around and change the field strength at the tip. Wrap coils tightly against the nail so they stay firmly in place.

Two students cooperating: one holding nail to sensor, one tapping wire to battery terminal

Step 5 of 7

Test 3 winds and check polarity

  1. One partner touches the nail tip to the sensor wand tip.
  2. The other partner presses the free wire end firmly to the top battery terminal; if reading decreases, reverse battery connections.
  3. When stable, tap Keep, type 3, tap Keep Point, and disconnect the wire immediately.
Stop and check
  • Keep the circuit closed for no more than 3 seconds.
  • Remove your finger. Release the wire immediately after you tap Keep.
  • Check the reading: if it went DOWN or turned negative, reverse the wire battery connections!

Careful: If you hold the wire to the battery continuously, the battery heats up and drains power quickly. Connect the wire only while you read the sensor. Disconnect the wire immediately.

2 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Direct Class 8, Science, chapter 4: Electricity: Magnetic and Heating Effects
  • Related Class 12, Physics, chapter 5: Magnetism and Matter
ICSE (CISCE)
  • Related Class 6, Physics, chapter 12: Properties and Uses of Magnet
  • Direct Class 7, Physics, chapter 16: Laws of Magnetism and Test for a Magnet
  • Direct Class 10, Physics, chapter 9: Electromagnetism and Magnetic Effects and Electromagnetic Induction

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.