Experiments › Chemistry
How strong is that brown peroxide bottle?
Peroxide Titration
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why do drugstores always sell hydrogen peroxide in dark brown bottles?
Show the answer
Hydrogen peroxide naturally breaks down into water and harmless oxygen gas when exposed to light. Today you will use an electrical potential sensor to find out if an old bottle has lost its germ-killing strength.

Introduction
How Strong Is That Brown Peroxide Bottle?
You probably have a brown bottle of hydrogen peroxide in your medicine cabinet. People dab it on scrapes because it fizzes and kills bacteria. But hydrogen peroxide molecules are unstable. Light makes them fall apart into plain water and oxygen bubbles. If a bottle sits in the cupboard for months, is it still strong enough to work? Today you will use deep purple potassium permanganate and a precision electrical sensor to count the active particles and test the label claim.
Driving question: Does that brown bottle of antiseptic hydrogen peroxide really contain the 3% strength printed on the label?
What you will learn
Today you will find out
- I can explain why brown bottles protect hydrogen peroxide from breaking down.
- I can describe how electrons move between chemicals in a redox reaction.
- I can spot the sudden voltage leap that marks the end of the reaction.
- I can read buret volumes accurately and follow lab safety rules.
- I can explain why hospital and pharmacy supplies must be tested for real chemical strength.
Why it matters: Hospitals rely on antiseptic chemicals to sterilize medical tools. If disinfectants degrade quietly in storage, patients risk infections. Scientists verify chemical strength using redox titrations.
Safety first
Scientist Rules for Today
- Wear splash goggles, protective lab aprons, and nitrile gloves at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Sulfuric acid and potassium permanganate are dangerous liquids that cause severe burns and stain skin. The adult handles these chemicals.
- Look for the ADULT NEEDED badge on high-risk steps.
- Never touch, taste, or sniff any lab solution, even household peroxide.
- Burets are long, delicate glass tubes: clamp them gently and handle with two hands.
- Keep all liquids at least 30 cm away from the tablet and sensor electronics.
- Wash hands fully with soap and warm water when finished.
What you need
- Go Direct ORP Sensor1 per station
- Stir Station and magnetic stir bar1 per station
- 50 mL buret and buret clamp1 per station
- Electrode Support1 per station
- 250 mL beaker2 per station
- Acidified dilute hydrogen peroxide solution50 mL per station
- 0.02 M KMnO4 solution60 mL per station
- Distilled water wash bottle1 per station
- Tablet running Graphical Analysis1 per station
- Safety goggles and nitrile gloves1 set per person

Step 1 of 7 Teacher does this
Prepare the acidified peroxide beaker
- Transfer 10.0 mL of dilute peroxide solution into a clean 250 mL beaker.
- Carefully add 4 mL of 4.5 M sulfuric acid and 16 mL of distilled water.
- Swirl the beaker gently until completely clear and colourless.
- Everyone wears splash goggles and gloves.
- Adult wears purple chemical-resistant gloves.
- Acid bottle is kept capped when not in use.
- Students observe from a safe distance with safety goggles on.
Careful: 4.5 M sulfuric acid causes severe chemical skin burns and permanent eye injury if splashed. Only the adult measures and dispenses the acid. Never lean over the beaker.

Step 2 of 7
Assemble the Stir Station and buret clamp
- Attach the buret clamp to the upper half of the metal rod.
- Slide the black Electrode Support arm onto the rod below the clamp and tighten its thumb screw.
- Place the 250 mL reaction beaker onto the circular stir plate. Drop a small magnetic stir bar inside.
- Stir Station power cord is routed safely away from walkways.
- The bench surface is completely dry.
- The metal rod is screwed tightly into the base.
- The Stir Station is placed flat on your bench with the metal rod screwed firmly into the base.
Careful: A loose support rod could wobble and cause tall glassware to tip over. Tighten all clamp screws hand-tight. Do not over-force plastic threads.

Step 3 of 7 Teacher does this
Fill the buret with purple permanganate
- Clamp the clean 50 mL glass buret securely in an upright position.
- Place a small plastic funnel at the top. Pour 0.02 M KMnO4 solution to the 0.0 mL mark.
- Drain a few drops into a waste beaker to fill the tip completely and clear trapped air bubbles.
- Adult wears purple nitrile gloves and safety goggles.
- Waste beaker rests directly under the buret tip.
- Buret stopcock turns smoothly and does not stick.
- The blue stopcock at the bottom of the buret is in the horizontal (closed) position.
Careful: Potassium permanganate is a powerful oxidizer that permanently stains clothes, skin, and tablet screens purple-brown. Only the adult pours KMnO4. Fill below eye level with a funnel.

Step 4 of 7
Position the Go Direct ORP sensor
- Unscrew the storage bottle from the ORP sensor. Rinse the probe tip fully with distilled water.
- Slide the red probe shaft through the Electrode Support's larger hole. Submerge the glass bulb and platinum ring in the peroxide solution.
- Turn on the Stir Station knob to a gentle, smooth spin.
- The stir bar spins gently and does not splash.
- The sensor tip is at least 5 mm away from the stir bar.
- ORP storage solution bottle is capped and placed safely aside.
- Make sure that the stir bar never touches the probe tip.
Careful: The magnetic stir bar could spin wildly and shatter the delicate glass tip of the ORP sensor. Start to stir at speed 0. Turn the knob up slowly until liquid gently swirls.

Step 5 of 7
Record the starting voltage at 0.0 mL
- Tap the green 'Collect' button in the Graphical Analysis app.
- Watch the live potential reading and wait 5 to 10 seconds for the number to become steady.
- Tap 'Keep', enter 0 as the volume in mL, and tap 'Keep Point'.
- The buret liquid level is read at eye level at the bottom of the meniscus.
- The stir bar spins gently without liquid splash.
- The ORP reading is steady around 550 to 570 mV.
- The buret is precisely at the 0.0 mL mark.
Careful: If you tap Keep before the voltage stabilizes, you will get a jumpy, inaccurate first point. Wait until the live millivolt number changes by less than 2 mV over 5 seconds.
2 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 12, Chemistry, chapter 4: The d- and f-Block Elements
- Related Level AS & A Level, Chemistry, chapter 24: Transition elements
- Related Level DP, Chemistry, chapter Reactivity 3.2: Electron transfer reactions
Versions and what each needs
- How strong is that brown peroxide bottle? (burette)
AP Chemistry, 60 min, Based on a Vernier lab
Needs: Go Direct ORP Sensor - How strong is that brown peroxide bottle? (drop counter)
AP Chemistry, 75 min, Based on a Vernier lab
Needs: Go Direct Drop Counter, Go Direct ORP Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.