Experiments › Chemistry
How strong is the bleach?
Oxidation Reduction Titrations
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does a drop of bleach make stains vanish instantly?
Show the answer
Bleach steals electric particles called electrons from colour molecules. Today, you will track this electron heist using an electrical sensor to measure the bleach's exact strength.

Introduction
The Electron Thief
Bleach is a powerful cleaning champion found in many homes. It removes tough stains and kills germs by snatching tiny negative particles called electrons. But how do scientists measure how strong a bottle of bleach really is? Today, you will add another chemical called hydrogen peroxide drop by drop. A high-tech sensor will track the electrical changes in real time. Watch closely: when the bleach runs out, the voltage will suddenly plummet!
Driving question: How can an electrical sensor reveal the secret strength of household bleach?
What you will learn
Today you will find out
- I can explain how bleach reacts by taking electrons from other substances.
- I can find the turning point where the voltage plummets on a graph.
- I can read the volume of liquid used at the reaction turning point.
- I can control a buret tap and collect steady sensor readings safely.
- I can describe how water treatment plants use chlorine reactions to keep water clean.
Why it matters: Water treatment plants, swimming pool managers, and hospitals all measure chemical power to kill germs without using too much chemical.
Safety first
Lab Rules for Chemical Titrations
- Wear splash goggles and protective gloves at all times. Bleach damages eyes and burns skin.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Bleach splashes permanently whiten clothes. Wear a laboratory apron.
- Only your teacher pipets concentrated bleach.
- Keep hands away from your eyes and face throughout the experiment.
- Never breathe in chemical fumes directly. Work in a well ventilated laboratory.
- Wash your hands fully with soap and water after cleanup.
What you need
- Go Direct ORP Sensor1
- Stir Station1
- Electrode Support1
- buret1 (50 mL)
- ring stand with clamp1
- 250 mL beaker1
- magnetic stir bar1
- 100 mL graduated cylinder1
- Distilled water wash bottle1
- commercial liquids10 mL commercial bleach · teacher
- clear solution in a reagent bottle60 mL 3% hydrogen peroxide
- Splash goggles and nitrile gloves1 set per person

Step 1 of 6 Teacher does this
Prepare the diluted bleach solution
- Have your teacher pipet exactly 10.00 mL of commercial bleach into a 250 mL beaker with a 10 mL pipet.
- Measure about 90 mL of distilled water with the graduated cylinder.
- Pour the distilled water into the beaker to bring the total volume to about 100 mL.
- Everyone has splash goggles and gloves on.
- Bleach stock bottle is kept on the teacher demonstration tray.
- The 250 mL beaker is clean and dry.
- Watch carefully as the teacher measures the liquid at eye level.
Careful: Bleach splashes cause eye injuries and irritate skin. Only the teacher dispenses concentrated bleach. Add water gently so it does not splash.

Step 2 of 6
Place the beaker on the Stir Station
- Place the 250 mL beaker with diluted bleach onto the Stir Station platform.
- Gently drop the white magnetic stir bar into the beaker.
- Turn on the stir knob to a slow, steady spin.
- Stir Station power cable is tucked safely away.
- The beaker sits squarely on the centre platform.
- Make sure the liquid stirs smoothly and does not splash or create a wild vortex.
Careful: If the stir speed is too fast, bleach can splash out of the beaker. Start at speed zero. Turn the knob slowly until a gentle swirl forms.

Step 3 of 6
Mount the ORP sensor in the liquid
- Unscrew the storage bottle from the ORP sensor and rinse the tip with distilled water.
- Slide the sensor body into the Electrode Support attached to the Stir Station post.
- Lower the sensor until its red probe tip enters about 3 cm into the bleach solution.
- Electrode Support thumbscrew is snug.
- The sensor tip is submerged in liquid.
- The stir bar spins freely and does not hit the probe tip.
- Position the sensor tip away from the stir bar so they never touch.
Careful: The stir bar can shatter the glass tip of the ORP probe. Position the probe near the side wall of the beaker, well clear of the stir bar.

Step 4 of 6 Teacher does this
Fill and mount the 50 mL buret
- Attach the buret clamp to the metal ring stand beside the Stir Station.
- Have your teacher check the tap is closed and fill the buret with 3% hydrogen peroxide.
- Drain a few drops into a waste cup to fill the tip, then adjust the level to exactly 0.00 mL.
- Buret stopcock is closed (horizontal).
- Ring stand base is stable and heavy.
- A small funnel is used to pour hydrogen peroxide.
- Position the tip of the buret directly above the open top of the beaker.
Careful: Hydrogen peroxide irritates skin and eyes if it spills when you pour it above head level. Lower the buret below eye level before you fill it. The teacher pours the peroxide.

Step 5 of 6
Record the starting voltage at 0.0 mL
- Tap Collect on the tablet to begin your titration run.
- Wait 10 seconds until the millivolt reading stabilizes.
- Tap Keep. Type 0 for the volume. Tap Keep Point.
- The buret stopcock is closed tight.
- The stir bar spins gently.
- The voltage reading on the screen is steady.
- Live potential reading on the screen should read between 620 and 650 mV.
Careful: If you tap Keep before the reading settles, the app records unstable numbers. Wait until the millivolt reading changes by less than 2 mV before you save the data.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Level AS & A Level, Chemistry, chapter 7: Redox reactions
- Direct Level AS & A Level, Chemistry, chapter 24: Transition elements
- Related Level AS & A Level, Chemistry, chapter 26: Carboxylic acids and their derivatives
Versions and what each needs
- How strong is the bleach?
Chemistry through Inquiry, 60 min, Based on a Vernier lab
Needs: Go Direct ORP Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.