Experiments › Chemistry
How strong is the blue liquid?
Colorimetry and Solution Concentration
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 10 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can a beam of light reveal the secret strength of a blue drink?
Show the answer
Darker liquids soak up more light. Scientists call this light absorption, and today you will measure it to find the exact concentration of a mystery blue liquid.

Introduction
How Strong Is That Blue Liquid?
When you look at a blue liquid, you cannot guess its exact chemical strength just by eye. But a light sensor can! Blue liquid looks blue because it soaks up red light and lets blue light pass. A concentrated liquid has lots of blue particles, so it soaks up more red light. In this lab, you will measure absorbed light and find the exact strength of a mystery liquid.
Driving question: Can a beam of light reveal the exact strength of a blue liquid?
What you will learn
Today you will find out
- I can explain which colour of light a blue liquid absorbs.
- I can dilute a liquid accurately using pipets.
- I can show that concentration and absorbed light increase together.
- I can find the unknown concentration using a graph.
- I can name real jobs where testing liquids with light is important.
Why it matters: Water treatment plants, blood testing labs, and environmental inspectors use light to measure invisible chemicals every single day.
Safety first
Safety Rules for Today
- Wear chemical splash goggles and protective gloves at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Copper sulfate solution causes skin and eye irritation. Do not touch your face.
- Never taste or drink any chemical in the lab.
- Keep all liquids at least 30 cm away from the tablet and sensor.
- Handle cuvettes only by the top rim. If glass breaks, inform your teacher immediately.
- Wash your hands fully with soap and water before you leave the lab.
What you need
- Go Direct Colorimeter1 per group
- Plastic cuvette (4 clear sides)1 per group
- Test tubes and rack6 test tubes and 1 rack
- 10 mL measuring pipet2 pipets with pumps
- 100 mL beakers2 beakers
- 0.40 M copper sulfate stock solution50 mL
- Unknown copper sulfate solution10 mL
- Distilled water wash bottle100 mL
- glass stirring rod1
- tissue wipes1 box
- Splash goggles and nitrile gloves1 set per student

Step 1 of 10 Teacher does this
Prepare the 0.40 M stock solution
- Dissolve 9.99 grams of solid copper sulfate in distilled water to make 100 mL of 0.40 M stock solution.
- Pour 50 mL into a clean beaker labelled '0.40 M CuSO4'.
- Watch carefully while you stand one step back.
- Teacher wears purple gloves and goggles.
- Students wear goggles and stand back.
- Close the solid chemical container after you weigh the chemical.
Careful: Solid copper sulfate pentahydrate dust irritates eyes and lungs if spilled. Only the adult measures the solid powder. Wipe any powder spills immediately.

Step 2 of 10
Label your test tubes
- Place five clean, dry test tubes into your rack.
- Label them 1 through 5 with a marker pen or sticky labels.
- Place a sixth test tube in the rack. Label it 'Unknown'.
- Test tubes are seated firmly in the rack.
- Labels are clear and easy to read.
Careful: Glass test tubes can roll off the bench and shatter. Always keep test tubes upright inside the rack.

Step 3 of 10
Prepare the standard dilutions
- Use one pipet for copper sulfate stock and another pipet for water.
- Add stock solution and distilled water to each tube as the table shows.
- Mix each tube fully with a clean glass rod.
- Wear goggles and blue gloves.
- Stock beaker is stable and away from bench edges.
- Pipets have labels so that liquids do not mix.
- Wipe the glass rod dry between tubes.
Careful: If you draw liquid too fast with the pipet pump, liquid can splash into your eyes. Turn the wheel on the pipet pump slowly. Never use your mouth.

Step 4 of 10
Connect the Go Direct Colorimeter
- Press the power button on your Go Direct Colorimeter.
- Connect to your sensor with Bluetooth.
- Select 'Event Based' data collection.
- Tablet is placed at least 30 cm away from liquids.
- Bench surface around the sensor is dry.
- Vernier Graphical Analysis is open on your tablet.
Careful: Liquid spilled on electronic sensors can damage internal circuits. Keep beakers and test tubes away from the tablet and sensor.

Step 5 of 10
Prepare the water blank cuvette
- Fill a clean plastic cuvette three quarters full with distilled water.
- Wipe the outside walls clean and dry with a lint-free tissue.
- Make sure that no air bubbles stick to the walls.
- Cuvette is filled three quarters, not to the brim.
- Lint-free tissue is ready.
- Handle the cuvette only by the top rim.
Careful: Fingerprints or droplets on the cuvette scatter the light beam. Touch only the ribbed top edge. Wipe the clear sides spotless.
5 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 10, Science, chapter 1: Chemical Reactions and Equations
- Related Class 10, Science, chapter 3: Metals and Non-metals
- Direct Class 10, Chemistry, chapter 4: Analytical Chemistry
Versions and what each needs
- How strong is the blue liquid? (spectrophotometer)
Chemistry through Inquiry, 75 min, Based on a Vernier lab
Needs: Go Direct SpectroVis Plus Spectrophotometer - How strong is the blue liquid? (colorimeter)
Chemistry through Inquiry, 60 min, Based on a Vernier lab
Needs: Go Direct Colorimeter
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.