Experiments › Chemistry
How to coat a key in copper
Electroplate
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 11 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
How do shiny gold jewellery and chrome car parts get their metallic shine?
Show the answer
They are not solid gold or chrome! Electric current carries tiny metal particles through a liquid bath to coat them. Today you will electroplate real copper onto a brass key.

Introduction
Painting with Metal and Electricity
Look closely at a gold-plated necklace or a shiny chrome car bumper. Most of the time, the object is made of a cheaper metal inside, with an ultra-thin skin of expensive metal on the outside. How did factory workers paint metal onto metal without melting it? They used electroplating! By dipping two metals into a special bath and running an electric current, metal dissolves from one side and plates onto the other. Today, you will use electric current to transfer real copper atoms onto a brass key.
Driving question: Can you use electricity to paint a metal key with real copper?
What you will learn
Today you will discover
- I can explain how electricity moves copper onto a brass key.
- I can measure how much mass the copper strip lost and the key gained.
- I can show that the new copper coating came from the dissolving copper strip.
- I can connect an electrical circuit and measure the current with a sensor.
- I can safely handle metal electrodes and keep liquids away from power outlets.
Why it matters: Electroplating prevents steel bridges and cars from rusting, keeps computer circuit boards conductive, and makes jewellery affordable.
Safety first
Lab Rules for Today
- Wear splash goggles, chemical-resistant gloves, and a lab apron at all times.
- Purple gloves = teacher does it. Blue gloves = you do it.
- The blue bath contains copper sulfate and sulfuric acid. It is corrosive and harmful if swallowed.
- The teacher prepares and pours the blue electrolyte bath. Students do not carry acid beakers.
- Keep all liquids at least 30 cm away from the wall outlet and power cables.
- Turn the current knob fully counterclockwise before you plug the power supply into the wall.
- Never let the copper strip touch the brass key directly inside the liquid. That causes a short circuit.
What you need
- Go Direct Constant Current System1 · teacher
- Tablet running Graphical Analysis1
- brass key1
- 1 cm × 10 cm copper strip1
- bare copper wire, 20–22 gauge1 piece (7 cm)
- 250 mL beakers2
- steel wool pad1 pad
- vinegar and solid sodium chloride, NaCl15 mL vinegar, 3 g salt
- electrolyte solution (CuSO4 in H2SO4)150 mL · teacher
- Distilled water wash bottle1 bottle
- Digital balance (0.01 g precision)1 per class
- Splash goggles and nitrile gloves1 set per person

Step 1 of 11
Scrub the metal pieces
- Put on your goggles and blue gloves.
- Rub the brass key and the copper strip firmly with steel wool until both shine brightly.
- Scrub the metal to remove invisible grease and tarnish so copper can stick firmly.
- Goggles are on your eyes.
- Blue gloves are on your hands.
Careful: Tiny steel wool splinters can poke skin or eyes. Keep goggles on and rub over a paper towel on the table.

Step 2 of 11
Wash with salt-vinegar cleaner
- In a 250 mL beaker, mix 3 g of salt with 15 mL of vinegar and stir.
- Dip the key and copper strip into the mixture for 10 seconds to strip oxide.
- Rinse both pieces fully with distilled water from your wash bottle. Dry them completely with a clean wipe.
- Vinegar is kept at your lab station.
- Clean paper wipes are ready.
Careful: Vinegar splashes hurt your eyes. Dip metal pieces slowly and wear goggles.

Step 3 of 11
Weigh both dry metals
- Weigh the dry copper strip and record its mass.
- Attach the 7 cm bare copper wire to the key to make a handle.
- Weigh the key together WITH its wire handle. Record this initial mass.
- Both metals are 100% dry.
- Hold metals only by the edges or with gloves so you do not leave finger oil.
- Zero your digital balance so the screen shows 0.00 g.
Careful: If you weigh wet metal, the initial mass is too high and ruins your results. Pat the metal completely dry with a paper towel before you put it on the pan.

Step 4 of 11 Teacher does this
Teacher pours the electrolyte bath
- The teacher fills a clean 250 mL beaker about 3/4 full with the blue electrolyte solution.
- This solution contains copper sulfate and sulfuric acid.
- Place the beaker gently in the center of your work tray. Do not touch or splash it.
- The teacher wears purple gloves, an apron, and splash goggles.
- Students keep hands back behind the safety tray.
- No food or drink anywhere in the lab.
Careful: The solution contains sulfuric acid which causes serious skin and eye burns. Only the teacher pours this liquid. If skin contact occurs, flush with water immediately.

Step 5 of 11 Teacher does this
Adult sets the current system to minimum
- Gently turn the blue dial on the Go Direct Constant Current System fully counterclockwise.
- This makes sure that the current starts at zero.
- The teacher plugs the power adapter into the wall outlet. The device is now ready.
- Dial is turned all the way counterclockwise to minimum.
- Outlets and bench area are completely dry.
Careful: If you connect the power supply with the dial turned up, a power surge or spark can occur. Make sure that the knob is at the minimum position before you connect the power supply to the wall.
6 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 12, Chemistry, chapter 2: Electrochemistry
- Related Class 10, Chemistry, chapter 6: Electrolysis
- Related Class 10, Chemistry, chapter 7: Metallurgy
- Related Level AS & A Level, Chemistry, chapter 20: Electrochemistry
- Direct Level DP, Chemistry, chapter Reactivity 3.2: Electron transfer reactions
Versions and what each needs
- How to coat a key in copper
Advanced Chemistry, 60 min, Based on a Vernier lab
Needs: Go Direct Constant Current System