Experiments › Environmental Science
Is fertilizer hiding in our water?
Ammonium Nitrogen
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why do peaceful country ponds sometimes turn thick, slimy green?
Show the answer
Fertilizers wash off farm fields during storms. We measure invisible dissolved ammonium to find out how much fertilizer entered the water.

Introduction
Is Fertilizer Hiding in Our Water?
Farmers use fertilizers to help crops grow strong and tall. But when heavy rain falls, extra fertilizer washes into nearby creeks and ponds. This runoff carries ammonium, a rich nutrient. Too much ammonium triggers huge algal blooms that choke out underwater life. Today, you will calibrate an electronic water sensor and detect invisible ammonium in water.
Driving question: How can we find invisible fertilizer hiding in our local waterways?
What you will learn
Goals for this investigation
- I can explain how extra fertilizer gets into natural water.
- I can calibrate an electrode using two standard liquids.
- I can accurately measure ammonium levels in water samples.
- I can tell if a water sample has harmful fertilizer levels.
- I can describe why high nutrient levels harm fish and pond life.
Why it matters: Clean water is essential for drinking, swimming, and wildlife. Environmental scientists track nutrients to stop toxic blooms before they spread.
Safety first
Safety Rules for Testing Water
- Wear splash goggles and lab gloves throughout the entire experiment.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Never taste or drink water samples or standard calibration liquids.
- Blot the electrode tip gently with tissue: do not rub or scrape the membrane.
- Keep all liquids at least 20 cm away from tablets and charging ports.
- Wash your hands with warm water and soap after the cleanup.
What you need
- Go Direct Ammonium ISE1
- Tablet running Graphical Analysis1
- High Standard (100 mg/L NH4+-N)50 mL
- Low Standard (1 mg/L NH4+-N)50 mL
- 100 mL beakers3
- Distilled water wash bottle1
- 250 mL beaker1
- Lint-free tissue box1 box
- Splash goggles and nitrile gloves1 set per student

Step 1 of 8
Check the pre-soaked electrode
- Make sure that your electrode soaked in the High Standard bottle for at least 30 minutes.
- Submerge the small white reference dots near the tip fully.
- Make sure that the probe tip stays above the bottle bottom and does not touch it.
- Splash goggles and light blue gloves are on.
- The standard bottle is upright and stable on the table.
Careful: Do not put the probe on the bottom. It can scratch or crack the delicate membrane. Keep the probe tip suspended 1 cm above the bottle floor.

Step 2 of 8
Connect the sensor to your tablet
- Press the power button on the Go Direct Ammonium ISE once.
- Open Graphical Analysis on your tablet. Then tap Sensor Data Collection.
- Select your probe from the list to connect.
- The tablet stands at least 20 cm away from liquids.
- Hands are gloved and dry before you touch electronics.
- The Bluetooth status light will start to flash red, then blink green once connected.
Careful: Liquid splashes on the tablet can damage the screen. Keep all open beakers on a tray away from the tablet.

Step 3 of 8
Calibrate reading 1: High Standard
- Pour 30 mL of High Standard (100 mg/L) into a clean 100 mL beaker.
- In the app, tap the sensor meter and choose Calibrate.
- Type 100 for Reading 1. Wait 60 seconds until stable. Then tap Keep.
- The beaker is labelled '100 mg/L High Standard'.
- Hold the sensor still so it does not hit the beaker glass.
- Keep the electrode in this High Standard solution while you calibrate.
Careful: If you tap Keep too early, you get an inaccurate calibration curve. Wait until the live voltage becomes stable. Then tap Keep.

Step 4 of 8
Rinse and blot the sensor
- Lift the electrode out of the High Standard beaker.
- Hold it over the waste beaker. Rinse fully with distilled water from the wash bottle.
- Gently blot the outside dry with a lint-free tissue.
- The waste beaker is directly below the probe tip.
- You have a fresh lint-free wipe ready in hand.
- Never rub the flat membrane at the tip: a rub ruins the sensor!
Careful: A hard wipe scratches the PVC membrane and contaminates the Low Standard. Only gently touch (blot) the tissue against the barrel and tip.

Step 5 of 8
Calibrate reading 2: Low Standard
- Pour 30 mL of Low Standard (1 mg/L) into a clean, labelled 100 mL beaker.
- Lower the electrode tip into the Low Standard solution and swirl gently for 5 seconds.
- Type 1 for Reading 2. Wait about 60 seconds until steady. Then tap Keep.
- The beaker is labelled '1 mg/L Low Standard'.
- White reference contacts are fully submerged.
- Hold the electrode tip still and do not touch the bottom of the beaker.
Careful: Trapped air bubbles under the sensor tip make the voltage jump erratically. Swirl briefly to remove all air bubbles from under the tip.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Level DP, Environmental Systems and Societies, chapter 4: Water and aquatic food production systems and societies
Versions and what each needs
- Is fertilizer hiding in our water?
Water Quality, 50 min, Based on a Vernier lab
Needs: Go Direct Ammonium Ion-Selective Electrode