This is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

A garden bed showing vibrant blue hydrangeas on one side and pink hydrangeas on the other

Wonder

Why do blue hydrangeas turn pink when you move them across the garden?

Show the answer

Hydrangea flower colours change because soil pH controls which minerals the plant roots can swallow. Today you will measure soil pH and discover what plants can feed on.

Two healthy potted tomato plants beside two contrasting trays of dark soil

Introduction

Why Do Gardeners Test Soil pH?

When farmers want healthy crops, they do not just look at the dirt. They test its pH! Soil can be acidic, neutral, or basic. When soil pH is too high or too low, minerals become locked in the dirt like treasures inside a locked box. Roots cannot absorb them, and plants starve even in rich earth. In this experiment, you will mix soil with pure water, let it settle, and measure its pH with a Go Direct pH Sensor.

Driving question: Why do farmers and gardeners test soil before planting their crops?

What you will learn

Today you will find out

  • I can prepare a soil mixture and measure its pH accurately with a sensor.
  • I can tell whether a soil sample is acidic, neutral, or basic from its pH number.
  • I can explain which plant nutrients become locked up when soil pH is too low or too high.
  • I can rinse the delicate glass electrode properly and protect it from rough soil grains.

Why it matters: Farmers, lawn caretakers, and forest ecologists test soil pH to protect crops and restore wild habitats.

Safety first

Scientist Rules for Today

  • Wear safety goggles, gloves, and a lab apron. Soil mixtures can splash when stirred.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • The pH sensor tip has a thin, delicate glass bulb. Never push it into hard gravel or tap it against beaker walls.
  • Keep all water bottles and beakers at least 30 cm away from your tablet or laptop.
  • Never taste or drink any liquid in the laboratory, even clear distilled water.
  • Rinse the probe gently with distilled water over a waste cup. Do not wipe the bulb with rough paper towels.
  • Wash your hands fully with warm water and soap after you touch soil.

What you need

  • Go Direct pH Sensor1
  • Tablet running Graphical Analysis1
  • two 250 mL beakers2
  • 100 mL graduated cylinder1
  • 2 soil samples50 g each (A and B)
  • wash bottle with distilled water1
  • distilled water250 mL
  • 2 plastic spoons2
  • waste cup1
  • pH soaking solution50 mL in beaker
  • paper towels4 to 6 sheets
Two glass beakers labelled A and B with dry soil and separate spoons resting inside

Step 1 of 7

Label beakers and add soil

  1. Mark your beakers 'A' and 'B' with a grease pencil or label.
  2. Put 50 g of Soil A into Beaker A. Keep the spoon inside.
  3. Use a fresh second spoon to put 50 g of Soil B into Beaker B. Keep that spoon inside.
Stop and check
  • Both beakers are clean and dry.
  • Each soil sample has its own separate plastic spoon.
  • Keep separate spoons to prevent a mixture of Soil A and Soil B.

Careful: If you share one spoon, soil grains move between samples and cause incorrect readings. Keep spoon A inside Beaker A and spoon B inside Beaker B at all times.

Student pouring 100 mL of distilled water into Beaker A

Step 2 of 7

Add distilled water for a 2:1 ratio

  1. Use the 100 mL graduated cylinder to measure exactly 100 mL of distilled water.
  2. Pour the 100 mL of water into Beaker A.
  3. Measure another 100 mL of distilled water. Pour it into Beaker B.
Stop and check
  • Use pure distilled water, not tap water.
  • Check the liquid level at eye level against the 100 mL line.
  • When you add 100 mL of water to 50 g of soil, you create a standard 2:1 water-to-soil ratio.

Careful: Tap water adds dissolved minerals that change the pH. Only pour from the distilled water jug or wash bottle.

A student hand stirring the muddy mixture in Beaker A with a plastic spoon beside a digital timer

Step 3 of 7

Stir every 3 minutes for 15 minutes

  1. Stir both mixtures fully with their assigned spoons.
  2. Start a stopwatch or timer for 15 minutes.
  3. Stir each beaker gently for 15 seconds once every 3 minutes.
Stop and check
  • Keep each spoon in its own beaker.
  • Stir gently so muddy liquid does not splash.

Careful: If you stir vigorously, muddy water can spill onto the table or clothes. Make slow, steady circular strokes with the plastic spoon.

Settled soil in Beaker A showing dark mud at the bottom and a clear liquid layer on top

Step 4 of 7

Let soil settle for 5 minutes

  1. After your final stir at 15 minutes, remove the spoons and set them on a paper towel.
  2. Leave both beakers completely still for 5 minutes. Do not move them.
  3. Connect your sensor on the next screen while you wait. Set data collection to Events Based with a 10-second average.
Stop and check
  • Do not bump or shake the table while soil settles.
  • Table surface is dry around the beakers.

Careful: If you bump the table, you stir up sediment and make the liquid layer cloudy. Keep hands off the beakers. Let gravity do the work.

Student hand holding Go Direct pH sensor submerged in the upper liquid layer of Beaker A

Step 5 of 7

Rinse probe and measure Soil A

  1. Remove the pH sensor from its storage beaker. Rinse the tip fully with distilled water into the waste cup.
  2. Carefully lower the sensor tip into the liquid layer in Beaker A.
  3. Tap Collect. Tap Keep for the 10-second countdown. Tap Keep a second time for Reading 2. Tap Stop.
Stop and check
  • Probe rinsed with distilled water over the waste cup.
  • Sensor tip is submerged in the clear liquid, not pressed into bottom dirt.
  • Keep the sensor tip submerged in water above the soil; do not shove it into mud.
  • Keep the probe completely still for the full 10-second countdown.

Careful: If you push the glass bulb into coarse sand or gravel, you can scratch or shatter the fragile membrane. Hover the slotted tip 1 to 2 cm above the mud layer while you hold the sensor body upright.

2 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Direct Class 7, Science, chapter 2: Exploring Substances: Acidic, Basic, and Neutral
  • Related Class 8, Science, chapter 1: Crop Production and Management
  • Direct Class 8, Science, chapter 12: How Nature Works in Harmony
  • Related Class 9, Science, chapter 12: Improvement in Food Resources
  • Direct Class 10, Science, chapter 2: Acids, Bases and Salts
Cambridge AS & A Level
  • Related Level AS & A Level, Biology, chapter 17: Selection and evolution
  • Related Level AS & A Level, Biology, chapter 18: Classification, biodiversity and conservation

Versions and what each needs