Experiments › Physics
The invisible magnetic reach
Mag Field Permanent Magnet
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 5 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does a magnet's grip drop to zero with just a tiny step back?
Show the answer
Magnetic forces do not fade slowly. They collapse with surprising speed as you move away. Today, you will measure this invisible cliff.

Introduction
The Invisible Magnetic Reach
Hold two strong magnets close, and they snap together with surprising force. Pull them just two centimeters apart, and you feel almost nothing. Why does magnetic force fade so fast? In this lab, you will use a high-precision magnetic sensor to track the strength of a magnet millimeter by millimeter.
Driving question: Why does a magnet's pull seem to vanish so suddenly when you step away?
What you will learn
Today you will find out
- I can measure magnetic field strength at different distances.
- I can explain how quickly magnetic strength fades with distance.
- I can line up and zero the magnetic sensor properly.
- I can read a graph that shows magnetic strength fading away.
- I can connect magnetic field reach to real-world technology.
Why it matters: Engineers designing wireless chargers, maglev bullet trains, and medical MRI scanners rely on knowing exactly where magnetic fields begin and end.
Safety first
Magnet Safety Rules
- Neodymium magnets are small but very strong. Keep your fingers clear when you move them together to avoid pinches.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Keep magnets at least 30 cm away from phones, tablets, credit cards, and computers.
- Never let strong magnets slam together hard; they are brittle and can chip.
- Do not put magnets in your mouth or near your face.
What you need
- Go Direct 3-Axis Magnetic Field Sensor1
- Neodymium disk magnets2
- Meter stick (wood or plastic)1
- Blank paper index card1
- Masking tape1 roll
- Tablet running Graphical Analysis1

Step 1 of 5
Mount the magnets onto the card
- Place one of your two small neodymium magnets on the front corner of the index card.
- Carefully bring the second magnet to the back corner so they snap together through the card.
- Keep fingers clear of the pinch zone when magnets snap together.
- Make sure that the magnets are at least 0.5 cm from the card edge.
Careful: Strong magnets can pinch skin or snap together hard enough to chip. Slide the magnets gently onto opposite sides of the card. Do not drop them.

Step 2 of 5
Tape down the meter stick and sensor
- Tape both ends of the wooden meter stick flat along your lab table so it cannot slide.
- Align the dots on the Go Direct sensor tip (0.5 cm behind wand tip) with the 0 cm mark.
- Tape the sensor wand down securely, parallel along the meter stick.
- Make sure that no metal clamps or iron objects are near the ruler.
- The sensor wand points toward higher numbers on the meter stick.
Careful: If the sensor moves during the experiment, background magnetic fields will ruin your data. Use two strips of tape to lock the sensor wand firmly to the table.

Step 3 of 5
Zero out background magnetic fields
- Move your magnet card at least 1 meter away from the sensor.
- In Graphical Analysis, tap the X Magnetic Field meter and select Zero.
- Confirm that the reading displays 0.00 mT.
- The magnet card is placed far away (at least 1 meter).
- No magnetic items are near the sensor wand.
- Make sure that no phones, watches, or steel scissors are near the sensor wand.
Careful: If you zero the sensor with the magnet nearby, you remove the magnet's field instead of background fields. Keep the magnet far away until you zero the sensor.

Step 4 of 5
Take your first reading at 3.0 cm
- Tap Collect to start data collection.
- Stand your index card perpendicular to the meter stick at the 3.0 cm mark (0.03 m).
- If negative, turn the card around so the opposite face points toward the sensor; when steady, tap Keep, type 0.03, and tap Keep Point.
- The card stands upright and straight against the meter stick.
- The reading is positive and under 5.0 mT.
- If the live reading is negative, flip the card around so it reads positive.
Careful: If you tilt the card, you change the magnetic pole angle and skew the reading. Keep the card flat and perfectly upright against the edge of the meter stick.

Step 5 of 5
Step outward and record points
- Slide the index card back by 0.5 cm to the 3.5 cm mark (0.035 m).
- Wait for the number to settle. Tap Keep. Type 0.035. Tap Keep Point.
- Repeat this process every 0.5 cm until you reach 7.0 cm (0.07 m). Tap Stop.
- Keep the sensor wand and meter stick completely still.
- Move only the index card.
Careful: If you bump the taped sensor, you shift your alignment. Slide the card smoothly along the ruler edge. Do not touch the sensor wand.
0 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Class 8, Science, chapter 8: Force and Pressure
- Direct Class 12, Physics, chapter 5: Magnetism and Matter
- Related Level AS & A Level, Physics, chapter 20: Magnetic fields
Versions and what each needs
- The invisible magnetic reach
Physics with Vernier, 45 min, Based on a Vernier lab
Needs: Go Direct 3-Axis Magnetic Field Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.