Experiments › Physics

The secret fingerprint of hydrogen

Spectrum of Atomic Hydrogen

Grades 7-8Physics1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

A glowing pink-violet glass tube projecting four sharp colour lines: red, cyan, and two violets

Wonder

How can looking at light tell us what an atom is doing inside?

Show the answer

Every glowing gas releases its own unique bar code of colours. Today you will decode the exact light lines of hydrogen to see electrons leaping inside atoms.

Comparison between a solid continuous rainbow and sharp separate emission bars

Introduction

The Secret Fingerprint of Hydrogen

When you look at a glowing light bulb, you see a smooth rainbow with every colour blended together. But when electricity excites pure hydrogen gas, something shocking happens: only four distinct colours of visible light appear! Why doesn't hydrogen produce all colours? In this lab, we will use a precision emissions spectrometer to measure these mystery lines and discover how jumping electrons create the atomic fingerprint of hydrogen.

Driving question: Why does glowing hydrogen gas shine in separate, sharp lines of colour instead of a continuous rainbow?

What you will learn

Today you will find out

  • I can tell the difference between a full rainbow and bright line spectra.
  • I can explain how jumping electrons create specific colours of light.
  • I can record the exact wavelengths of hydrogen emission lines using a spectrometer.
  • I can connect bigger energy drops to violet light and smaller drops to red light.
  • I can describe how astronomers use light fingerprints to find what stars are made of.

Why it matters: Astronomers cannot visit distant stars, yet they know exactly what gases burn inside them just by reading their emission lines.

Safety first

High Voltage and Hot Glass Rules

  • High Voltage Alert: The spectrum tube power supply uses 5000 volts! Only the teacher plugs, touches, or adjusts the tube socket.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Hot Glass: Spectrum tubes become extremely hot during operation. Never touch the glass tube even when switched off.
  • Short Duty Cycle: Hydrogen tubes degrade quickly when hot. Turn on the power only while you collect data. Then turn off the power immediately.
  • Keep hands, cables, and liquids far away from the power supply terminals.
  • Handle the optical fibre gently; sharp bends or kinks can crack the glass core inside.

What you need

  • Go Direct Emissions Spectrometer1 per station
  • Vernier Emissions Optical Fiber1 per station
  • Spectrum tube power supply + tubes1 per station · teacher
  • Hydrogen spectrum tube1 per station · teacher
  • straight-line filament incandescent bulb and socket1 per station · teacher
  • replica diffraction grating1 to 2 per group
  • Tablet running Graphical Analysis1 per group
  • safety goggles1 per person
Student looking through diffraction grating slide at a glowing straight-filament bulb

Step 1 of 7 Teacher does this

Observe continuous light with a grating

  1. The teacher turns on the straight-line incandescent filament lamp.
  2. Hold your diffraction grating close to your eye like a pair of spectacles.
  3. Look slightly to the side of the lit bulb filament.
  4. Notice how the white filament stretches into a continuous unbroken rainbow.
Stop and check
  • Bulb is seated securely in the insulated socket.
  • Students stand at least 50 cm back from the hot lamp.
  • Teacher operates the power cord.

Careful: Incandescent lamps get hot enough to cause burns; bare mains wires could shock. Do not touch the bulb glass. Look only through the handheld slide.

Teacher flipping power switch on spectrum supply; student viewing glowing pink tube through grating

Step 2 of 7 Teacher does this

Observe glowing hydrogen gas

  1. The teacher inserts the hydrogen tube into the power supply and flips the power switch ON.
  2. The narrow centre of the tube glows with a bright magenta-pink light.
  3. Look at the tube through your diffraction grating.
  4. Notice the difference: instead of a full rainbow, you see separate bright coloured lines!
Stop and check
  • Power supply is switched OFF while the teacher seats the tube.
  • Nobody touches the tube clips or power terminals.
  • The teacher turns on the power only when everyone is ready.

Careful: 5000 V electrical shock hazard; tube glass becomes hot within seconds. Keep hands 20 cm away from the power unit. Only the teacher flips the switch.

Student hand threading the metal optical fibre connector onto the Go Direct spectrometer port

Step 3 of 7

Attach the optical fibre to the spectrometer

  1. Take the Vernier Emissions Optical Fiber.
  2. Screw the knurled metal connector gently onto the threaded SMA port of the Go Direct spectrometer.
  3. Tighten it with your fingers until snug. Never use pliers or force it.
  4. Keep the long black cable in gentle curves. Do not bend it tightly.
Stop and check
  • Spectrometer sits flat and stable on the lab table.
  • Optical fibre ends are clean and dust-free.

Careful: If you cross-thread the metal screw connector or kink the glass fibre, you can ruin the optical path. Turn gently clockwise by hand. Keep the cable loosely looped.

Tablet screen displaying Spectral Analysis opening screen selecting Emissions vs Wavelength

Step 4 of 7

Connect spectrometer and choose Emissions mode

  1. Turn on the Go Direct Emissions Spectrometer. The LED flashes.
  2. Open Spectral Analysis on your tablet. Connect your spectrometer with Bluetooth or USB.
  3. Choose 'Emissions' and then select 'vs. Wavelength (Full Spectrum)'.
  4. Open the gear Settings icon. Set the integration time to 40 ms.
Stop and check
  • Spectrometer battery is charged or USB cable connected.
  • Bluetooth is turned on on the tablet.

Careful: If you select Absorbance or the wrong mode, the sensor cannot measure emitted light from the tube. Always choose 'Emissions' mode, full spectrum.

Metal fibre tip secured in bracket 2 cm from glowing vertical pink hydrogen tube

Step 5 of 7 Teacher does this

Aim the optical fibre at the glowing tube

  1. Place the metal tip of the optical fibre into the bracket on the power supply.
  2. Aim the tip directly at the narrowest centre portion of the hydrogen spectrum tube, about 2 cm away.
  3. The teacher turns ON the hydrogen power supply.
  4. Make sure that the fibre tip points straight into the lit magenta column.
Stop and check
  • Optical fibre metal tip does not touch the glass tube (keep at least 1 cm space).
  • Hands stay clear of the power supply sockets.
  • Teacher operates the power switch.

Careful: If you touch the high-voltage electrodes, you will get a dangerous electrical shock. The plastic fibre probe can melt if it touches hot glass. Secure the probe in the bracket before you turn on the power. Never touch the lit tube.

2 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

CBSE (NCERT)
  • Related Class 9, Science, chapter 4: Structure of the Atom
  • Direct Class 11, Chemistry, chapter 2: Structure of Atom
  • Direct Class 12, Physics, chapter 4: Atoms
Cambridge AS & A Level
  • Direct Level AS & A Level, Chemistry, chapter 2: Electrons in atoms
  • Related Level AS & A Level, Chemistry, chapter 11: Group 2
  • Direct Level AS & A Level, Physics, chapter 22: Quantum physics
IB Diploma
  • Direct Level DP, Physics, chapter 16: E.1 Structure of the atom
  • Direct Level DP, Chemistry, chapter Structure 1.3: Electron configurations

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.