Experiments › Chemistry

What colours hide in purple soda?

Separating Food Dyes with Column Chromatography

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 9 steps. To run it with the sensors, record data and take the quiz, students use the app.

A glass of purple soft drink splitting into separate streams of red and blue liquid

Wonder

Is purple soda made of real purple dye, or is it a trick?

Show the answer

Purple drinks are almost always a mixture of separate red and blue food dyes. Today you will trap them on a tiny chemical column, peel them apart using rubbing alcohol, and identify each dye using a light sensor.

A clear glass filled with fizzy purple grape soda and ice cubes, glowing in bright sunlight

Introduction

Unmasking Hidden Colours

Look closely at a bright purple sports drink or grape soda. Did the factory use single purple dye crystals? In fact, true purple food dye does not even exist on the approved food colour list! Instead, food companies blend red and blue dyes together. Today you will learn about column chromatography and light absorption to separate the colours and identify each food dye.

Driving question: Can we pull apart the hidden colours inside purple soda and identify each dye?

What you will learn

Today you will discover

  • I can explain how chromatography separates colours in a mixture.
  • I can separate two different coloured dyes from a purple drink.
  • I can identify unknown food dyes using their light absorption peaks.
  • I can make alcohol dilutions and run a syringe separation column safely.
  • I can name real-world jobs that use chromatography to test mixtures.

Why it matters: Chromatography is used by airport security to detect dangerous chemicals, by Olympic testers to spot illegal drugs, and by food inspectors to verify safe ingredients.

Safety first

Laboratory Safety Rules

  • Wear chemical splash goggles, protective gloves, and a lab apron at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • 70% isopropyl alcohol is flammable and can irritate eyes and skin. Keep it away from open heat.
  • Never taste, sip, or drink the soft drink or any solution in the laboratory.
  • Keep electronic devices and the spectrophotometer at least 30 cm away from all liquids.
  • Never pull the syringe backward while it connects to the cartridge. You will ruin the inside material.
  • Wash your hands fully with soap and warm water when you finish.

What you need

  • Go Direct SpectroVis Plus Spectrophotometer1 per station · teacher
  • Plastic cuvette (4 clear sides)2 cuvettes with lids
  • C18 Sep-Pak cartridge1 cartridge
  • plastic syringe1 (10 mL)
  • two-hole #5 rubber stopper1 stopper
  • Test tubes and rack6 small test tubes in rack
  • 150 mL beaker6 beakers
  • 10 mL graduated cylinders1 cylinder
  • can of carbonated soft drink50 mL grape soft drink
  • 70% isopropyl alcohol60 mL in dropper bottle · teacher
  • Distilled water wash bottle1 wash bottle
  • commercial liquidsFood dye standards (Red No. 40, Blue No. 1)
Gloved fingers sliding a water cuvette into the SpectroVis Plus slot

Step 1 of 9

Calibrate the spectrophotometer with water

  1. Fill a clean cuvette three quarters full with distilled water.
  2. Wipe the clear faces with a lint-free tissue to remove smudges.
  3. Put the cuvette into the SpectroVis Plus. Tap Finish Calibration.
Stop and check
  • Goggles and gloves are on.
  • The cuvette contains only pure distilled water.
  • The outside of the cuvette is completely dry.
  • Handle the cuvette only by the top edge of its ribbed sides.

Careful: Fingerprints or droplets on the cuvette scatter light and distort all readings. Wipe the clear sides fully. Examine the cuvette against room light before you put it in.

SpectroVis Plus holding a purple liquid cuvette next to a tablet showing two peaks

Step 2 of 9

Scan the purple soft drink

  1. Fill the cuvette three quarters full with the soft drink.
  2. Put it in the spectrophotometer. Tap Collect.
  3. Tap Stop once the graph appears, and rename the run 'Grape Drink'.
Stop and check
  • The soft drink is flat and free of carbonation bubbles.
  • The cuvette clear faces are wiped dry.
  • The cuvette is rinsed with a small splash of grape soft drink.

Careful: Bubbles that stick to the inside of the cuvette cause erratic, bumpy graphs. Tap the side of the cuvette gently with a fingernail to remove any bubbles.

Five labelled beakers in a row showing serial dilution with a 10 mL graduated cylinder

Step 3 of 9 Teacher does this

Prepare the alcohol dilutions

  1. Pour 20 mL of 70% alcohol into the 70% beaker.
  2. Mix 10 mL of 70% alcohol with 10 mL of water in the 35% beaker.
  3. Mix 10 mL from the 35% beaker with 10 mL water in 17.5%. Repeat with 10 mL water for 8.75% and 4.38%.
Stop and check
  • An adult supervises when you pour alcohol.
  • Goggles are on and there are no open flames or heaters nearby.
  • Beakers are clearly labelled.
  • Five 150 mL beakers are labelled: 70%, 35%, 17.5%, 8.75%, and 4.38%.

Careful: Alcohol fumes can irritate you. If you confuse the beakers, you ruin the separation steps. Double-check labels before you transfer liquids. Keep beakers covered when not in use.

Syringe attached to C18 cartridge on rubber stopper in a test tube rack

Step 4 of 9

Assemble and rinse the C18 cartridge

  1. Draw 5 mL of 70% alcohol into the syringe and attach it to the cartridge.
  2. Gently push the alcohol through into the tube, then discard this rinse.
  3. Repeat with 5 mL of distilled water to wet the cartridge.
Stop and check
  • The test tube sits firmly in the rack.
  • You attach the syringe without force.
  • IMPORTANT: Never pull the syringe backwards while attached.
  • The short end of the C18 cartridge is inserted into the two-hole stopper.
  • The stopper is placed securely into Test Tube 1 in your rack.

Careful: If you pull the plunger backward, air or inside material moves backward. This ruins the cartridge. Always detach the syringe before you pull the plunger back to draw liquid.

Dark purple band trapped on the white C18 cartridge as clear liquid drips out

Step 5 of 9

Load soft drink onto the column

  1. Detach the syringe and draw up exactly 5.0 mL of grape soft drink.
  2. Attach the syringe back onto the pretreated C18 cartridge.
  3. Push the drink slowly through the cartridge into Test Tube 1.
Stop and check
  • You detached the syringe before you pulled up the soft drink.
  • The cartridge is firmly seated over Test Tube 1.

Careful: If you push too quickly, you can force dye straight through before it binds. Push slowly and smoothly over 15 to 20 seconds.

4 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

IB Diploma
  • Direct Level DP, Chemistry, chapter Structure 1.1: Introduction to the particulate nature of matter

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.