Wonder
How can detectives prove a harmless jar of cosmetic cream was tampered with?
Show the answer
Someone swapped normal makeup remover with harsh lye. Today you will use acid drops to neutralise it and catch the clue.

Introduction
The Dressing Room Evidence
Before a theater show, an actor noticed their makeup remover smelled strangely soapy and felt slippery. Investigators seized the jar from the dressing room. They suspect someone stirred strong drain cleaner lye into it! Lye is sodium hydroxide, a powerful chemical base. In this lab, you act as forensic scientists. You will add measured drops of acid to neutralise the base and measure exactly how much was added.
Driving question: How can forensic chemists figure out what was secretly added to a jar of makeup?
What you will learn
Today you will find out
- I can explain how an acid cancels out a base.
- I can spot the sharp drop on a pH graph.
- I can find how much acid neutralised the mystery sample.
- I can assemble the titration station with my team.
- I can describe how forensic labs test suspicious liquids.
Why it matters: Cosmetics, food, and medicines must undergo quality control to guarantee they are safe and pure.
Safety first
Lab Rules for Chemical Testing
- Wear safety goggles, lab coat, and gloves at all times. Dilute acids and bases irritate skin and eyes.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Look for the ADULT NEEDED badge. Only your teacher prepares the stock solutions and handles concentrated liquids.
- Keep all liquid containers at least 30 cm away from tablets and charging ports.
- Never taste or smell any mystery solution in a lab.
- If any chemical splashes on skin, rinse immediately with cold tap water for 15 minutes.
What you need
- Go Direct pH Sensor1
- Go Direct Drop Counter1
- Vernier Stir Station and stir bar1
- plastic 60 mL reagent reservoir1
- 0.1 M Hydrochloric acid solution60 mL
- Diluted evidence makeup remover (prepared by teacher)5 mL in 40 mL water
- 10 mL graduated cylinders1
- Distilled water wash bottle1
- Tablet running Graphical Analysis1
- Splash goggles and nitrile gloves1 set per student

Step 1 of 8 Teacher does this
Adult prepares the dilute evidence sample
- Your teacher takes 5.0 mL of concentrated makeup remover evidence.
- They dilute it with distilled water to 100 mL in a volumetric flask.
- From this flask, measure 5.0 mL into a 100 mL beaker and add 40 mL distilled water.
- Everyone has goggles and gloves on.
- The concentrated stock bottle remains closed until ready.
- Students watch from a safe distance.
Careful: Undiluted evidence contains concentrated sodium hydroxide, which can cause severe skin irritation. Only the adult measures the undiluted stock with a pipet bulb. Never pipet by mouth.

Step 2 of 8
Assemble the Stir Station and sensors
- Slide the Drop Counter clamp onto the Stir Station rod.
- Insert the Go Direct pH Sensor through the large round hole in the Drop Counter.
- Clamp the 60 mL reagent reservoir directly above the Drop Counter slot.
- Clamps are firm but not over-tightened.
- Drop Counter is positioned directly over the stir plate.
- Cables stay away from parts that move.
Careful: If you drop the glass pH probe, you can crack the sensitive glass bulb. Grip the pH probe body securely and slide it gently through the clamp hole.

Step 3 of 8
Learn the two reservoir valves
- Identify the two blue turn-valves on the reservoir.
- Set the top valve to roughly 1 drop every 2 seconds.
- Turn both valves horizontal so no liquid leaks out.
- Both valve handles are horizontal (closed).
- A waste beaker is placed beneath the tip to catch any test drips.
- The bottom valve is the main ON/OFF switch: horizontal is closed, vertical is open.
Careful: If you leave valves open when you pour acid, acid will spill all over the stand. Make sure that both blue handles are horizontal before you add liquid.

Step 4 of 8
Fill the reservoir with 0.1 M acid
- Pour about 50 mL of 0.1 M hydrochloric acid into the reservoir.
- Turn both valves vertical for 2 seconds to fill the tip with liquid.
- Close both valves. Make sure no trapped air bubbles stay in the dropper tip.
- You wear goggles and gloves.
- Waste beaker is positioned right below the tip.
- You pour slowly with two hands.
- Hold a 250 mL waste beaker beneath the tip.
Careful: If you pour too fast, acid can splash onto hands or the table. Pour acid steadily into the wide top hole. Wipe any drips immediately with a damp towel.

Step 5 of 8
Calibrate the Drop Counter
- Place a 10 mL graduated cylinder directly below the slot of the Drop Counter to collect the drops.
- In Graphical Analysis, tap Volume meter, choose Calibrate, and open the bottom valve fully.
- Adjust the top valve to 1 drop every 2 seconds. At 9 to 10 mL, close the bottom valve. Tap Done.
- 10 mL cylinder is stable directly under the drop window.
- Tablet is connected to the Drop Counter.
- Drops fall through the center of the slot.
- Place a clean 10 mL graduated cylinder directly beneath the Drop Counter slot.
Careful: Drops that hit the side of the slot do not fall freely and cause volume errors. Line up the reservoir tip so every drop passes clean through the middle of the slot.
3 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Level DP, Chemistry, chapter Structure 1.4: Counting particles by mass: The mole
Versions and what each needs
- What contaminated the makeup? (drop counter)
Forensic Chemistry, 60 min, Based on a Vernier lab
Needs: Go Direct Drop Counter, Go Direct pH Sensor - What contaminated the makeup? (burette)
Forensic Chemistry, 55 min, Based on a Vernier lab
Needs: Go Direct pH Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.