What does yeast do with sugar?

Metabolism

Grades 7-8Biology2 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

A loaf of freshly baked crusty bread sliced open showing airy holes created by yeast bubbles

Wonder

Why does bread dough puff up with tiny pockets of air?

Show the answer

Living yeast feast on sugar and exhale invisible carbon dioxide gas. Today you will track their breathing rate with a digital gas sensor in real time.

Microscopic illustration of single-celled yeast cells absorbing sugar molecules and releasing carbon dioxide bubbles

Introduction

How Fast Do Yeast Breathe Sugar?

Baker's yeast may look like tiny dry grains, but they are living microscopic fungi! When you wake them up with warm water and feed them sugar, they get straight to work. Yeast break down food molecules to get energy in a process called cellular respiration. As they metabolize glucose, they pump out carbon dioxide gas. Today you will feed yeast sugar, trap their exhaled gas in a closed chamber, and measure their respiration rate in real time.

Driving question: How quickly do hungry yeast cells eat sugar and exhale gas?

What you will learn

Today you will find out

  • I can explain how yeast turn sugar into carbon dioxide gas.
  • I can track rising carbon dioxide gas using a digital sensor.
  • I can find the respiration rate from the slope of my graph.
  • I can keep a water bath at a steady temperature to run a fair test.
  • I can explain how bakers and fuel makers use yeast respiration.

Why it matters: Bakers rely on yeast gas to make bread rise, and biotechnology plants use yeast fermentation to brew eco-friendly biofuels. Measuring cell metabolism helps scientists optimize both.

Safety first

Laboratory Safety Guidelines

  • Wear splash goggles and lab aprons at all times. Protect eyes from splashes.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Never taste or ingest any laboratory chemicals or yeast solutions.
  • Handle warm water carefully to avoid burns. Hot water must never exceed 50°C.
  • Keep all liquids and wet glassware away from tablets and charging ports.
  • Secure glassware with clamps so the beaker and respiration chamber do not tip over.
  • Wash your hands fully with soap and water after you complete the lab.

What you need

  • Go Direct CO2 Gas Sensor1 per station
  • Go Direct Temperature Probe1 per station
  • Sampling Chamber (250 mL / 2 L)1 per station
  • 1 L beaker1 per station
  • ring stand with clamp1 stand, 2 clamps
  • Plastic Beral pipets2 pipets with bulbs
  • plastic syringe1 (10 mL to 30 mL)
  • cloudy biological liquid5 mL active suspension
  • clear solution in a reagent bottle5 mL (0.30 M glucose)
  • clear liquid in a wash bottleWarm and cool tap water
  • Tablet running Graphical Analysis1 per station
Student hand adjusting water in a 1000 mL beaker with temperature probe clamped

Step 1 of 7

Prepare the 30°C water bath

  1. Pour about 600 mL of water into your 1000 mL glass beaker.
  2. Mix warm and cool water until your Go Direct Temperature Probe reads between 29°C and 31°C.
  3. Clamp the Temperature Probe to the ring stand so its metal tip sits in the water bath.
Stop and check
  • Water is comfortably warm, never dangerously hot.
  • The 1000 mL beaker is placed securely on the bench away from edges.
  • All electronic cables and tablets are at least 30 cm away.

Careful: Hot water could splash if poured too quickly. Pour gently. Use small amounts of warm or cool water to adjust the temperature.

Student gloved hand drawing 1 mL from the middle of a stirred yeast beaker

Step 2 of 7

Pipet active yeast into the chamber

  1. Go to the shared yeast station where the suspension stirs on the magnetic stirrer.
  2. Insert your 1 mL pipet into the MIDDLE of the liquid as it spins. Draw up exactly 1.0 mL.
  3. Carefully transfer the 1.0 mL of yeast suspension into the bottom of your dry 250 mL respiration chamber.
Stop and check
  • The magnetic stirrer turns at a steady gentle speed.
  • Pipet is clean and fitted with a rubber bulb.
  • Respiration chamber is clean and completely dry inside.

Careful: Liquid from settled bottom sediment or surface foam gives an uneven yeast concentration. Dip the pipet tip into the middle depth of the stirred liquid to get an evenly mixed sample.

Student gently swirling the mixed glucose and yeast in the respiration chamber

Step 3 of 7

Add glucose sugar and swirl gently

  1. Use a fresh clean 1 mL pipet. Draw up 1.0 mL of 0.30 M glucose solution.
  2. Add the 1.0 mL of glucose directly into the respiration chamber with the yeast.
  3. Swirl the chamber gently in a flat circle for 5 seconds so the sugar and yeast mix fully.
Stop and check
  • Glucose solution bottle is clearly labeled 0.30 M.
  • A clean pipet is used so the stock bottle is not contaminated.
  • Wear gloves and safety goggles.

Careful: Vigorous movement can splash yeast liquid up the chamber walls where it can touch the sensor shaft. Swirl gently on the tabletop in a smooth flat circle for 5 seconds.

Student twisting the CO2 sensor into the neck of the respiration chamber

Step 4 of 7

Insert the CO2 sensor into the chamber

  1. Take the Go Direct CO2 Gas Sensor and align its tapered shaft with the neck of the respiration chamber.
  2. Turn the sensor gently. Press the sensor firmly into the chamber neck to make an airtight seal.
  3. Do not push so hard that you crack the plastic. Make sure that no gaps remain around the neck.
Stop and check
  • Chamber liquid is settled at the bottom and cannot splash sensor holes.
  • Sensor shaft is dry and clean.
  • The chamber rests firmly on the bench.

Careful: If the sensor is loose, carbon dioxide gas will leak out and your measured rate will be falsely low. Twist gently as you push downward until the rubber grommet fits snugly inside the chamber mouth.

Assembled setup showing chamber clamped in the water bath beaker with CO2 sensor upright

Step 5 of 7

Submerge the chamber in the water bath

  1. Loosen the utility clamp on the ring stand and slide the respiration chamber into the water bath.
  2. Submerge the lower chamber into the 29-31°C water bath. Keep the yeast mixture completely below the water line.
  3. Tighten the clamp around the chamber neck. Keep the top of the sensor above water and dry!
Stop and check
  • The water level does not reach the electrical case of the CO2 sensor.
  • The utility clamp thumbscrew is finger-tight and holds the chamber securely.
  • The temperature probe stays in the water bath.

Careful: If the water level is too high, water could splash into the CO2 sensor electronics. Only submerge the plastic chamber body. Keep the black sensor handle completely above water.

2 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

IB Diploma
  • Direct Level DP, Sports, Exercise and Health Science, chapter 3: Energy Systems
  • Direct Level DP, Biology, chapter B1.1: Carbohydrates and lipids
  • Direct Level DP, Biology, chapter C1.1: Enzymes and metabolism
  • Direct Level DP, Biology, chapter C4.2: Transfers of energy and matter
  • Direct Level DP, Biology, chapter D2.2: Gene expression

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.