Experiments › Chemistry

What is hiding in the white powder?

Purity of a Mixture

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

Two small ceramic kitchen spoons with identical white powders side by side on a wooden table

Wonder

Can you tell two identical white powders apart without tasting them?

Show the answer

They look identical, but they conduct electricity differently and release trapped gas when vinegar touches them. Scientists call these properties electrical conductivity and gas pressure, and today you will measure them to solve the mystery.

A kitchen baking counter showing baking soda next to a laundry soap container

Introduction

The Mystery of the Twin White Powders

Imagine you find two containers of white powder in a pantry: one is baking soda for baking cakes, and the other is washing soda for washing clothes. They look completely identical! How can a scientist discover what is in a mystery mixture of the two? Today, you will use two high-tech tools: a conductivity probe that measures tiny electric currents carried by dissolved particles in water, and a gas pressure sensor that measures bubbles of trapped gas when vinegar is added.

Driving question: Two white powders look completely identical. Can electricity and trapped gas tell them apart?

What you will learn

Today you will find out

  • I can explain why washing soda conducts electricity better than baking soda.
  • I can use a conductivity probe to test different liquid mixtures.
  • I can observe and measure gas pressure created during a chemical reaction.
  • I can compare test results to decide which method is best and safest.
  • I can give examples of how scientists check white powders in factories and forensic labs.

Why it matters: Pharmaceutical companies, food factories, and environmental scientists test powders every day to make sure medicines and foods are pure and safe.

Safety first

Laboratory Rules for Today

  • Wear safety goggles, lab aprons, and nitrile gloves at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Never taste or consume any powder or liquid in the lab. People use baking soda to cook food, but lab chemicals are not food grade.
  • Washing soda can irritate eyes and skin. If powder touches your hands, rinse immediately with clean water.
  • Keep all liquids at least 30 cm away from tablets and sensor bodies.
  • Make sure that the stopper on the reaction flask is firmly in place before you collect gas. Never use force to jam it.
  • Wash your hands fully with soap and water after you clean up.

What you need

  • Go Direct Conductivity Probe1
  • Go Direct Gas Pressure Sensor1
  • Stir Station1
  • Test tubes and rack6 tubes in 1 rack
  • 125 mL Erlenmeyer flask1
  • 10 mL graduated cylinders2
  • Two-hole rubber stopper with valve and tubing1 set
  • Prepared solutions of baking soda and washing soda100 mL each
  • Commercial liquids (white vinegar)50 mL
  • Digital balance (0.01 g precision)1 per station
  • Distilled water wash bottle1
  • Splash goggles and nitrile gloves1 set per student
Student hand placing labels 1 to 6 on test tubes in a rack

Step 1 of 8

Label your test tubes

  1. Place six clean glass test tubes in your test tube rack.
  2. Use sticky labels to number them 1 through 6 from left to right.
  3. Check that each tube sits upright and steady in the rack.
Stop and check
  • Goggles and gloves are on.
  • The rack is placed on a flat, dry table.

Careful: Glass tubes can tip over and shatter if placed on the bare bench. Always keep test tubes secure inside the plastic rack.

Gloved student hand carefully pouring clear liquid from a 10 mL cylinder into a test tube

Step 2 of 8

Measure and mix the solutions

  1. Use one 10 mL cylinder for baking soda solution and the other for washing soda solution.
  2. Add the exact volumes listed in the table to each tube so every tube has 10 mL total.
  3. Gently swirl each tube so the two liquids mix completely.
Stop and check
  • Two cylinders are dedicated to separate solutions.
  • Bottles are clearly labelled NaHCO3 and Na2CO3.

Careful: If you swap the cylinders, you cross-contaminate the stock solutions. Keep each cylinder next to its own correct supply beaker.

Student lowering the conductivity probe tip into test tube 1

Step 3 of 8

Measure Tube 1 conductivity

  1. Rinse the probe tip with distilled water from your wash bottle and pat it dry with a tissue.
  2. Lower the probe into Tube 1 until the liquid fully covers the hole near the tip.
  3. When the live number stabilizes, tap Keep, type 9 for the baking soda volume, and tap Keep Point.
Stop and check
  • Wash bottle has distilled water, not tap water.
  • The probe hole is fully under the liquid.

Careful: If the hole near the probe tip is half-exposed, the reading will be erratic and too low. Make sure that the liquid fully covers the tip hole. Do not let the tube overflow.

Student rinsing the conductivity probe with distilled water over a waste beaker

Step 4 of 8

Measure Tubes 2 through 6

  1. Remove the probe. Rinse it fully with distilled water. Pat it dry.
  2. Insert the probe into Tube 2. Wait for a steady number. Tap Keep. Type 8.
  3. Repeat this routine for Tubes 3, 4, 5, and 6. Tap Stop when you record all 6 points.
Stop and check
  • Always rinse with distilled water between every single tube.
  • Pat gently with a clean tissue; do not scrape the electrodes.

Careful: If you transfer liquid from one tube to the next, you ruin the volume ratios. Rinse over a waste beaker and pat dry before each new tube.

125 mL Erlenmeyer flask clamped on a Stir Station with stir bar spinning in liquid

Step 5 of 8

Assemble the gas reaction setup

  1. Place the 125 mL Erlenmeyer flask on the Stir Station and secure it with a utility clamp.
  2. Add 10 mL of vinegar, 15 mL of distilled water, and carefully drop the magnetic stir bar inside.
  3. Turn on the Stir Station so the bar spins gently and does not splash.
Stop and check
  • Flask clamp is snug, not overtightened against the glass.
  • Stir speed is gentle (setting 2 to 3).

Careful: Fast rotation throws acid droplets up onto the neck and table. Start at speed zero and slowly dial up to a smooth gentle vortex.

3 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

Cambridge AS & A Level
  • Related Level AS & A Level, Chemistry, chapter 3: Atoms, molecules and stoichiometry
IB Diploma
  • Related Level DP, Chemistry, chapter Reactivity 2.1: How much? The amount of chemical change

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.