Experiments › Chemistry
What is in the mystery liquid?
Gas Chromatograph Unknown
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
How can you tell what is inside a clear mystery liquid?
Show the answer
Different liquids travel at different speeds through a coated tube. Scientists call this chromatography, and today you will separate and identify a mystery liquid.

Introduction
The Molecular Obstacle Race
Imagine a race where every runner faces a sticky obstacle course. Light runners who ignore the obstacles sprint across the finish line first. Runners who stop to chat with the obstacles arrive much later. Gas chromatography works the exact same way. It evaporates a tiny drop of liquid and blows it down a coated tube. Different chemicals exit at different times, revealing their true identities.
Driving question: How can detectives identify invisible chemicals mixed inside a clear liquid?
What you will learn
Today you will find out
- I can explain how a gas chromatograph separates mixed liquids.
- I can find the retention time of each peak on a graph.
- I can explain why liquids with lower boiling points usually exit faster.
- I can identify mystery liquids by matching their exit times.
- I can practice lab safety around organic vapours and heated equipment.
Why it matters: Forensic detectives, fragrance designers, and food safety inspectors use gas chromatography every day to identify trace chemicals.
Safety first
Laboratory Safety Rules
- Wear splash goggles, chemical-resistant gloves, and a long-sleeve lab coat.
- Work inside an active fume hood or near open windows. Organic vapours irritate lungs.
- Purple gloves = teacher does it. Blue gloves = you do it.
- The syringe needle is sharp and fragile. Only the teacher handles the glass syringe.
- The Mini GC injection port is hot. Never touch the metal nut on top.
- All solvents are flammable. Keep open flames and sparks far away from the bench.
- Wash your hands fully with soap after the lab.
What you need
- Go Direct Mini GC1 per station · teacher
- 1 μL glass syringe1 · teacher
- Tablet running Instrumental Analysis1 per group
- Set of 6 known solvent vials1 set (methanol, ethanol, 2-butanone, propyl acetate, 4-methyl-2-pentanone, butyl acetate) · teacher
- Unknown mixture vial1 vial labelled Unknown 1 · teacher
- Lint-free tissue box1 box
- Splash goggles and nitrile gloves1 set per person

Step 1 of 7 Teacher does this
Power on and pair the Mini GC
- Connect the Go Direct Mini GC to its power adapter. Switch it on.
- Open the Vernier Instrumental Analysis app on your tablet or laptop.
- Connect to the Mini GC over Bluetooth or USB cable.
- Notice the LED light on the instrument. It turns yellow while the instrument warms up.
- The power cord is connected firmly and does not stretch across aisles.
- Table is clean and free of water or spills.
- The fume hood ventilation fan is turned on.
Careful: The instrument draws 24 V power and has internal heating elements. Only an adult plugs in the high-voltage power brick. Keep all open liquid containers away.

Step 2 of 7
Program the temperature ramp
- In Instrumental Analysis, tap the settings gear to open the GC method.
- Set Start Temperature to 40°C with a Hold Time of 1 minute.
- Set Ramp Rate to 10°C per minute and Final Temperature to 60°C.
- Set Hold Time to 5 minutes, Total Length to 15 minutes, and Pressure to 18 kPa.
- Tap Apply so the Mini GC begins to heat to its start temperature.
- The tablet is paired with the Mini GC.
- Parameters match Table 1 exactly.
Careful: Wrong temperature profile causes peaks to bunch together or take too long. Carefully double-check the 40°C start and 10°C/min ramp before you tap Apply.

Step 3 of 7 Teacher does this
Flush and load the syringe
- The teacher rinses the 1 μL glass syringe two times with methanol into a waste vial.
- The teacher draws 0.30 μL of methanol (the first known standard) into the syringe with no air bubbles.
- Wipe the outside of the needle carefully with a clean lint-free wipe.
- Teacher wears goggles and purple nitrile gloves.
- Syringe needle is straight and undamaged.
- Waste bottle is open and ready inside the fume hood.
- Syringe barrel is cleared of all traces of previous chemicals.
Careful: The glass syringe needle is very sharp and thin. If you force the plunger, you bend the tiny wire. Only the adult touches the syringe. Handle gently by the glass barrel.

Step 4 of 7 Teacher does this
Inject standard and start the run
- Check that the Mini GC LED light is solid green. This shows that the temperature is ready.
- The teacher inserts the needle straight through the rubber septum into the injection port.
- In one smooth motion, press the plunger down, press the GC button, and pull the needle out.
- The timer starts immediately as the liquid flashes into vapour inside the column.
- Mini GC LED is solid green.
- Students stand one step back from the instrument.
- Injection path is clear with no sideways angle.
Careful: The injection port is heated. Pushing the needle in at an angle can bend it or ruin the septum. Insert the needle straight up-and-down. Push smoothly and withdraw immediately.

Step 5 of 7
Record known standard retention times
- Watch the graph as each standard liquid runs through the column.
- When a substance exits, a peak rises and drops back down.
- Use Peak Integration in the app to find the exact top of the peak in minutes.
- Record the retention time for all six known standards in your reference table.
- The graph actively plots points.
- The reference table is open in your lab notebook.
Careful: If you stop the run too early, you can cut off peaks that exit late. Wait until the peak returns completely to baseline before you stop the run.
2 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Direct Level AS & A Level, Chemistry, chapter 30: Analytical chemistry
Versions and what each needs
- What is in the mystery liquid?
Organic Chemistry, 60 min, Based on a Vernier lab
Needs: Go Direct Mini GC
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.