Experiments › Chemistry

What is the perfect chemical recipe?

Continuous Variations and Mole Ratios

Grades 7-8Chemistry1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Two clear liquids mixing in a beaker with warm thermal glow

Wonder

Why does baking bread fail if you put too much yeast or flour?

Show the answer

Every recipe needs a balanced ratio so no ingredient is wasted. Chemicals do the same thing! Today you will find the hidden recipe ratio of a mystery reaction using heat.

Measured baking ingredients in ceramic bowls next to freshly baked cookies on a kitchen table

Introduction

The Secret Recipe of Chemicals

When you bake cookies, mixing the wrong ratio of butter to flour ruins the batch. Chemical particles also react in fixed recipe numbers! When an acid and base react, they release heat. If you mix the exact recipe with no leftovers, the mixture gets hottest. Today you test different mixing ratios to uncover the mystery recipe ratio.

Driving question: How can temperature reveal the secret recipe ratio of a chemical reaction?

What you will learn

Today you will find out

  • I can explain why the peak temperature shows the best mixing recipe.
  • I can track and compare temperature rises for different liquid mixtures.
  • I can find the secret mixing ratio from the peak on a graph.
  • I can assemble the reaction cup and temperature probe correctly.
  • I can name real-world examples where getting the exact chemical ratio is critical.

Why it matters: Engineers balance fuel and oxygen in rocket engines so every gram of fuel burns cleanly with zero waste.

Safety first

Lab Rules for Strong Solutions

  • Wear safety goggles, lab aprons, and nitrile gloves at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • 1.0 M Sodium hydroxide can cause skin burns and eye damage. An adult measures and dispenses it.
  • Never taste or inhale any lab chemicals.
  • Keep tablet and sensor wires away from liquid containers.
  • Report any splash or spill immediately to your teacher.
  • Wash your hands fully with soap and water after cleanup.

What you need

  • Go Direct Temperature Probe1
  • Stir Station1
  • magnetic stir bar1
  • Electrode Support1
  • 50 mL graduated cylinder2
  • 25 mL graduated cylinder2
  • 10 mL graduated cylinders2
  • 1.0 M sodium hydroxide, NaOH, solution200 mL · teacher
  • 1.0 M unidentified acid solution200 mL
  • foam cup1
  • 250 mL beaker3
  • Tablet running Graphical Analysis1
  • Splash goggles and nitrile gloves1 set per person
Foam cup nested inside a glass beaker on top of the Stir Station

Step 1 of 7

Set up your insulated reaction cup

  1. Place a foam cup inside a 250 mL glass beaker.
  2. Place the nested cup in the centre of the Stir Station platform.
  3. Drop one clean magnetic stir bar into the cup.
Stop and check
  • The beaker sits flat on the stir platform.
  • The foam cup is dry and uncracked.

Careful: An unnested foam cup can easily tip over and spill liquid across the bench. Always keep the foam cup nested inside the heavy glass beaker.

Temperature probe clamped above foam cup on stir station

Step 2 of 7

Mount the temperature probe

  1. Attach the Electrode Support clamp to the Stir Station upright rod.
  2. Slide the Go Direct Temperature Probe into the clamp holder.
  3. Lower the clamp until the probe tip sits 1 cm above the cup bottom.
Stop and check
  • Clamp thumbscrew is tightened firmly.
  • Probe tip does not scrape against the stir bar.
  • Make sure the metal tip will not touch the stir bar when it spins.

Careful: The stir bar can strike the probe tip when it spins and damage equipment. Position the probe slightly off-centre so the bar spins freely beneath it.

Adult pouring sodium hydroxide solution into the foam cup

Step 3 of 7 Teacher does this

Have an adult dispense sodium hydroxide

  1. An adult pours exactly 30.0 mL of 1.0 M sodium hydroxide into a 50 mL graduated cylinder.
  2. Carefully transfer the 30.0 mL of base into the foam cup.
  3. Turn on the Stir Station knob to a gentle, steady speed.
Stop and check
  • Everyone has safety goggles and gloves on.
  • The base bottle has a tight cap after you pour.
  • Hands are dry.
  • Observe the live temperature reading until it stays steady.

Careful: 1.0 M sodium hydroxide is caustic and causes chemical burns if splashed on skin or eyes. Only the adult dispenses base. Rinse any skin contact with plenty of cold water immediately.

Student measuring 30 mL of acid in graduated cylinder at eye level

Step 4 of 7

Measure the matching volume of acid

  1. Use the cylinder labelled Acid to measure exactly 30.0 mL of mystery acid.
  2. Read the bottom of the curved meniscus at eye level.
  3. Keep the acid cylinder ready next to the Stir Station.
Stop and check
  • You use the cylinder labelled Acid.
  • Cylinder base sits flat on the table while reading.
  • Do NOT pour the acid into the cup yet!

Careful: If you mix too early, you ruin the baseline temperature measurement. Wait until data collection starts before you add the acid.

Student pouring acid into the stirred cup while graph line climbs

Step 5 of 7

Start data collection and mix Trial 1

  1. Tap Collect on Graphical Analysis. Wait 5 seconds to record the initial baseline.
  2. Pour the 30.0 mL of mystery acid into the stirred foam cup.
  3. When the temperature peaks and stays level for 15 seconds, tap Stop.
Stop and check
  • The stir bar spins smoothly.
  • The baseline has recorded for at least 5 seconds.

Careful: Liquid can splash out of the cup if you pour too fast. Pour smoothly down the inner side of the cup.

2 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

IB Diploma
  • Direct Level DP, Chemistry, chapter Reactivity 2.1: How much? The amount of chemical change

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.