Experiments › Chemistry
What is the perfect reaction recipe?
Reaction Stoichiometry
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Can mixing two room-temperature clear liquids create sudden heat?
Show the answer
When acids and bases meet, they release warmth. When you find the perfect balance of ingredients, the temperature jumps the highest!

Introduction
The Search for the Perfect Recipe
Baking a cake needs the right balance of flour and sugar. Too much of one leaves leftovers. Molecules behave the exact same way. When an acid and a base combine, they react and release heat energy. If both ingredients match up perfectly, every single particle reacts, releasing the most heat. Today, you will test different ratios to discover the reaction recipe using a temperature sensor.
Driving question: How can temperature tell us the secret recipe of a chemical reaction?
What you will learn
Today you will find out
- I can explain why chemical reactions need a matching recipe ratio.
- I can measure temperature changes during a chemical reaction using a sensor.
- I can find the best reaction recipe from the peak of a temperature graph.
- I can work safely with acids, bases, and glassware in the lab.
- I can describe how real industries use exact reaction recipes.
Why it matters: Engineers building rocket engines and pharmacists making medicines must calculate exact chemical recipes so nothing is wasted.
Safety first
Lab Rules for Working with Acids and Bases
- Wear safety goggles, lab aprons, and nitrile gloves throughout the lab.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Sodium hydroxide (NaOH) is caustic and can cause severe skin burns. An adult pours bulk supplies.
- Acetic acid produces a sharp vapor that stings. Do not sniff the bottles directly.
- If any liquid splashes onto skin or eyes, rinse immediately with cold water for 15 minutes.
- Keep tablet screens and wires at least 30 cm away from all liquid beakers.
- Wash your hands fully with soap and warm water when you clean up.
What you need
- Go Direct Temperature Probe1
- Stir Station1
- Electrode Support1
- magnetic stir bar1
- 25 mL and 50 mL graduated cylinders2 of each
- 400 mL beaker1
- foam cup1
- clear solution in a reagent bottle150 mL (1.0 M NaOH) · teacher
- clear liquid in a wash bottle150 mL (1.0 M Acetic Acid)
- Tablet running Graphical Analysis1
- Splash goggles and nitrile gloves1 set per person

Step 1 of 7
Assemble the calorimeter cup and Stir Station
- Nest the white foam cup snugly inside the 400 mL glass beaker.
- Place the nested cup in the centre of the Stir Station platform.
- Carefully drop the magnetic stir bar into the bottom of the foam cup.
- The Stir Station power cord is placed away from walkways.
- The foam cup has no cracks or leaks.
Careful: Do not drop a stir bar too hard. It can punch a hole through the foam bottom. Tilt the cup slightly and slide the stir bar down the inner wall gently.

Step 2 of 7
Mount the temperature probe
- Slide the Electrode Support clamp onto the Stir Station support rod.
- Insert the Go Direct Temperature Probe handle into the support hole.
- Lower the clamp until the metal probe tip sits deep inside the cup.
- Clamp thumbscrew is tightened securely.
- Probe tip is at least 1 cm above the stir bar.
- Make sure that the probe tip does not touch the stir bar that spins at the bottom.
Careful: If the probe hits the magnetic bar as it spins, it clicks loudly and causes erratic readings. Leave a 1 centimetre gap between the probe tip and the bottom of the cup.

Step 3 of 7 Teacher does this
Measure and add sodium hydroxide solution
- Under adult supervision, measure exactly 25.0 mL of 1.0 M NaOH in a graduated cylinder.
- Pour the 25.0 mL of NaOH into the foam cup.
- Turn on the Stir Station to a gentle, steady spin (speed dial around 3 or 4).
- Both student and teacher wear splash goggles and gloves.
- An adult pours or examines the 1.0 M NaOH volume.
- Paper towels are ready for any minor drips.
- Read the bottom of the liquid curve at eye level.
Careful: Sodium hydroxide is a caustic base that damages eyes and skin if splashed. Pour slowly down the inside of the cylinder. Keep your face away from the top.

Step 4 of 7
Measure acetic acid solution
- Use a separate clean graduated cylinder. Measure exactly 25.0 mL of 1.0 M acetic acid.
- Keep the cylinder upright on the bench next to the Stir Station.
- Double-check that the total volume of both solutions together will equal 50.0 mL.
- Use the dedicated acid cylinder, not the base cylinder.
- Goggles remain securely over eyes.
- Do not mix the liquids yet.
Careful: If you mix cylinders, you contaminate stock solutions before the reaction starts. Keep the acid cylinder on the left and the base cylinder on the right.

Step 5 of 7
Record baseline, add acid, and capture temperature rise
- Tap Collect in Graphical Analysis.
- Wait 10 seconds while the probe records the steady initial temperature.
- Carefully pour all 25.0 mL of acetic acid into the foam cup as it stirs.
- The stir bar spins steadily and does not splash.
- Probe is submerged at least 2 cm into the liquid.
- Watch the line curve upward as heat is released and let data collect for 180 seconds.
Careful: If you pour too fast, droplets can splash out of the cup. Pour smoothly. Do not hit the cylinder against the probe.
2 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 10, Chemistry, chapter 5: Mole Concept and Stoichiometry
- Related Level DP, Chemistry, chapter Reactivity 2.1: How much? The amount of chemical change
Versions and what each needs
- What is the perfect reaction recipe?
Chemistry through Inquiry, 75 min, Based on a Vernier lab
Needs: Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.