Experiments › Physics

What makes gas push?

Behavior of a Gas

Grades 7-8Physics1 version

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 8 steps. To run it with the sensors, record data and take the quiz, students use the app.

A bicycle tire pump pushing air into an expanding tire tube

Wonder

Why does a balloon pop when squeezed or left in a hot car?

Show the answer

Trapped air particles bounce billions of times per second. Squeezing or heating makes them hit harder. Today you will measure that invisible push.

A fully inflated bicycle tyre resting on a sunlit pavement

Introduction

What Makes Gas Push?

Air looks completely empty, but it is packed with trillions of tiny particles zooming in all directions. Every time they slam into a wall, they give it a tiny push. Together, those collisions create gas pressure. What happens when you squeeze the gas into less space? What happens when you add more air, or heat it up? Today you will discover the rules that gases obey.

Driving question: What gives air the power to push, squeeze, and lift?

What you will learn

Today you will discover

  • I can explain how gas particles create pressure.
  • I can show that expanding volume lowers trapped gas pressure.
  • I can demonstrate that adding more gas particles increases pressure.
  • I can show that heating a trapped gas makes pressure rise.
  • I can assemble gas sensors and follow water bath safety rules.

Why it matters: Scuba divers, weather forecasters, aircraft engineers, and car tire makers all rely on gas pressure laws.

Safety first

Lab Rules for Gas Experiments

  • Wear safety goggles throughout the experiment.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Water that boils can cause severe scalds. Only the adult pours hot water.
  • Never force the syringe plunger past the maximum mark.
  • Keep tablet and cables away from water beakers.
  • Wipe up any spilled water on the table immediately.

What you need

  • Go Direct Gas Pressure Sensor1
  • Go Direct Temperature Probe1
  • plastic syringe1 (20 mL)
  • 125 mL Erlenmeyer flask1 with stopper & tubing
  • 400 mL beaker1
  • 250 mL beaker2
  • ring stand with clamp1 set
  • boiling water200 mL · teacher
  • ice cubes1 cup crushed
  • Tablet running Graphical Analysis1
Attaching the 5 mL syringe to the gas pressure sensor

Step 1 of 8

Set up the syringe to 5.0 mL

  1. Disconnect the 20 mL syringe from the sensor. Take the syringe.
  2. Pull the plunger until the front edge of the black ring sits at 5.0 mL.
  3. Gently twist the syringe tip onto the gas pressure sensor valve until snug.
Stop and check
  • Set the syringe to 5.0 mL BEFORE you attach it.
  • Twist gently; do not over-tighten the plastic valve.

Careful: Too much twist can crack the plastic Luer-lock connector. Turn half a turn until snug. Do not force.

Student tapping Keep Point on tablet at 5 mL

Step 2 of 8

Record your first point at 5.0 mL

  1. Tap Collect in Graphical Analysis.
  2. Wait until the pressure reading steadies near atmospheric pressure (around 95 to 100 kPa).
  3. Tap Keep. Type 5 in the volume field. Tap Keep Point.
Stop and check
  • Pressure sensor shows a steady reading.
  • Plunger has not slipped from 5.0 mL.

Careful: If you tap Keep before the reading is steady, you record noisy data. Wait 3 seconds until the numbers steady.

Two students collaborating to hold syringe plunger and record point

Step 3 of 8

Expand volume step by step

  1. One student firmly holds the sensor. Pull the plunger to 7.5 mL.
  2. Hold it steady. When the pressure reading settles, tap Keep and type 7.5.
  3. Repeat this in 2.5 mL steps (10.0 mL, 12.5 mL, 15.0 mL, 17.5 mL).
  4. Tap Stop when you have at least 6 points. Disconnect the syringe.
Stop and check
  • Hold the plunger firmly; the vacuum will try to pull it back in.
  • Do not yank the plunger out of the syringe barrel.

Careful: If you release the plunger, it snaps forward and loses the volume mark. Grip the plunger rod firmly until your teammate taps Keep Point.

Starting a new Selected Events experiment in Graphical Analysis

Step 4 of 8

Set up Part 2: Counting puffs of air

  1. In Graphical Analysis, tap File and choose New Experiment.
  2. Choose Sensor Data Collection, then tap Mode and select Event Based.
  3. Choose Selected Events. Type 'Number' as Event Name and 'puffs' as Units.
  4. We will call 3.0 mL of normal room air one 'puff'.
Stop and check
  • Syringe is disconnected from the sensor.
  • App mode is set to Selected Events.

Careful: If you keep the old data, you overwrite your Volume graph. Save your Part 1 file before you start the new experiment.

Syringe set at constant 10 mL mark while measuring puffs

Step 5 of 8

Measure pressure from 1 puff to 6 puffs

  1. Pull 1 puff (3 mL) of air into the open syringe. Twist the syringe onto the sensor. Pull to 10 mL. Tap Keep.
  2. Disconnect the syringe. Pull in 2 puffs (6 mL) of air. Connect the syringe again. Move the plunger to 10 mL.
  3. Tap Keep. Add 1 puff each time (3 puffs = 9 mL, 4 puffs = 12 mL, etc.). Always test at 10 mL.
Stop and check
  • Always set the puffs BEFORE you attach the syringe to the sensor.
  • Always test the pressure at the EXACT same 10 mL mark.
  • Wait until the pressure reading is steady before you tap Keep.

Careful: If you test at different volumes, you change two variables at once. Hold the plunger exactly at 10 mL for every single measurement.

3 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

Cambridge AS & A Level
  • Related Level AS & A Level, Physics, chapter 15: Ideal gases
IB Diploma
  • Direct Level DP, Physics, chapter 6: B.3 Gas Laws

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.