Experiments › Chemistry

What makes reactions speed up?

Rate and Order

Grades 7-8Chemistry2 versions

A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.

Try it in View mode

Alpha: being verified by teachers

This is how the lab opens in the Stemious app: the first 5 of its 11 steps. To run it with the sensors, record data and take the quiz, students use the app.

A clear liquid mixing with another clear liquid to rapidly produce an amber yellow colour

Wonder

Why do some chemical reactions burst instantly while others take hours?

Show the answer

Chemical particles must bump into each other to react. When you pack more particles into the liquid, they collide more often. Today you will measure this speed using light.

Two glasses of water on a kitchen table showing an effervescent tablet fizzing rapidly in one glass and slowly in another

Introduction

What Makes Reactions Speed Up?

Some chemical changes happen in an instant, while others take days. When particles react, they must bump into each other to create something new. In this lab, you will explore reaction rate by watching two clear liquids react to form an amber colour. You will discover how crowding more particles together makes the reaction happen faster.

Driving question: What makes a chemical reaction speed up or slow down?

What you will learn

Today you will discover

  • I can explain what reaction rate means in a chemical reaction.
  • I can observe and measure how reactant strength affects reaction speed.
  • I can identify which chemical controls the reaction rate.
  • I can calibrate and use a colorimeter to record data over time.
  • I can explain why concentration and speed matter in daily life.

Why it matters: Engineers control reaction speeds to manufacture medicines safely, preserve food longer, and build better batteries.

Safety first

Lab Rules for Today

  • Wear safety goggles, lab aprons, and nitrile gloves at all times.
  • Purple gloves = teacher does it. Blue gloves = you do it.
  • Iron(III) chloride solution contains dilute hydrochloric acid. An adult dispenses this liquid.
  • Never taste any chemical or touch your face during lab.
  • If any chemical touches your skin, rinse immediately with cold tap water for 5 minutes.
  • Wipe all cuvettes carefully so no liquid gets inside the colorimeter slot.
  • Wash your hands fully with soap and water after the cleanup.

What you need

  • Go Direct Colorimeter1
  • Tablet running Graphical Analysis1
  • Plastic cuvette (4 clear sides)2
  • 25 mL graduated cylinder3
  • 100 mL beakers3
  • clear solution in a reagent bottle60 mL (0.020 M KI)
  • yellow or orange liquid in a reagent bottle60 mL (0.020 M FeCl3 in HCl) · teacher
  • Distilled water wash bottle100 mL
  • Lint-free tissue box1 box
  • Splash goggles and nitrile gloves1 set per student
Three labelled graduated cylinders and three labelled beakers on bench

Step 1 of 11

Label your glassware

  1. Label your three 25 mL graduated cylinders: 'KI', 'FeCl3', and 'Water'.
  2. Label two 100 mL beakers: 'KI' and 'FeCl3'.
  3. Label the third 100 mL beaker: 'Reaction Mix'.
  4. Separate cylinders prevent chemicals from premature mix.
Stop and check
  • All glassware is clean and dry.
  • Permanent marker or sticky labels are ready.

Careful: Accidental chemical contact if cylinders are mixed up. Always keep each cylinder next to the beaker with the same label.

Go Direct Colorimeter connected wirelessly to a tablet

Step 2 of 11

Connect the Colorimeter

  1. Press the power button on your Go Direct Colorimeter.
  2. Open Graphical Analysis on your tablet or computer.
  3. Connect to your Colorimeter over Bluetooth.
  4. Check that the sensor light turns green.
Stop and check
  • Sensor battery is charged.
  • Bluetooth is enabled on your device.

Careful: Bluetooth connection drops if the sensor is too far from the tablet. Keep the tablet within one metre of the colorimeter.

Student holding cuvette by ribbed sides and wiping with tissue

Step 3 of 11

Prepare a distilled water blank

  1. Fill a clean cuvette three-quarters full with distilled water.
  2. Hold the cuvette only by its ribbed top sides.
  3. Wipe the smooth clear sides with a lint-free tissue.
  4. Tap gently on the bench to remove any tiny bubbles.
Stop and check
  • Use only distilled water for the blank.
  • Cuvette clear sides are free of smudges.

Careful: Fingerprints or droplets on the outside block light and alter calibration. Wipe the clear faces fully with a lint-free wipe.

Go Direct Colorimeter with lid closed and finger pressing CAL button

Step 4 of 11

Calibrate the Colorimeter at 430 nm

  1. Open the Colorimeter lid. Place the water cuvette into the slot.
  2. Make sure the clear faces line up with the light path. Then close the lid.
  3. Press the arrow button on the sensor to select 430 nm (blue light).
  4. Press the CAL button. Calibration finishes when the red LED stops its flash.
Stop and check
  • Colorimeter lid closes completely flat.
  • 430 nm indicator light is selected.

Careful: An open lid lets room light enter and ruins calibration. Keep the lid firmly closed during measurement or calibration.

Adult pouring amber FeCl3 solution from stock bottle into labelled beaker

Step 5 of 11 Teacher does this

Adult dispenses iron(III) chloride

  1. Your teacher will pour 0.020 M FeCl3 into your group beaker.
  2. Teacher pours about 60 mL into the beaker labelled 'FeCl3'.
  3. Keep this beaker on the safety tray at all times.
Stop and check
  • Adult wears splash goggles and purple nitrile gloves.
  • Beaker sits steady on the lab tray.
  • Students keep hands back.

Careful: FeCl3 contains dilute hydrochloric acid, which can irritate skin and damage eyes. Only the adult pours from the stock acid reagent bottle.

6 more steps, then data, observations, conclusions and a quiz

The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.

Get the full lab, free for teachers

Where it fits in the syllabus

Cambridge AS & A Level
  • Related Level AS & A Level, Chemistry, chapter 7: Redox reactions
  • Direct Level AS & A Level, Chemistry, chapter 9: Rates of reaction
  • Related Level AS & A Level, Chemistry, chapter 22: Reaction kinetics
IB Diploma
  • Direct Level DP, Chemistry, chapter Reactivity 2.2: How fast? The rate of chemical change

Versions and what each needs

Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.