Experiments › Biology
What makes you need to breathe?
Oxygen Gas and Respiration
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 6 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does your body force you to breathe after holding your breath?
Show the answer
Holding your breath builds up carbon dioxide gas inside your blood. That rising gas triggers your brain to inhale. Scientists call this respiration, and today you will measure it.

Introduction
What Makes You Need to Breathe?
Most people can hold their breath for about a minute. Soon, an overwhelming urge forces you to gasp for air. Does your body gasp because it ran out of oxygen? Or is another gas sounding the alarm? In this experiment, you will capture your held breath in a collection bag. A precision oxygen gas sensor will reveal how much oxygen remains in your lungs.
Driving question: Why can you not hold your breath forever?
What you will learn
Today you will find out
- I can measure how much oxygen remains in my exhaled breath.
- I can compare breath-holding times between normal breathing and rapid breathing.
- I can explain what signal forces the body to breathe again.
- I can set up and run the gas sensor and breath collection bag.
- I can relate breathing control to freediving and medical monitoring.
Why it matters: Understanding how blood gases control breathing helps doctors treat lung diseases and helps divers train safely.
Safety first
Health and Safety Rules
- A person with asthma, bronchitis, or heart conditions must not hold their breath.
- Never force yourself past dizziness: if you feel faint, stop immediately and breathe normally.
- Never breathe rapidly when you swim or stay near water. This causes underwater blackout.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Each student must use their own clean bread bag for sanitary breath collection.
- Wash your hands with soap after you touch lab equipment.
What you need
- Go Direct O2 Gas Sensor1
- ring stand1
- utility clamp1
- bread bag1 per student
- roll of tape1 roll
- Tablet running Graphical Analysis1

Step 1 of 6
Tape bag to sensor snout
- Push the grey snout of the O2 sensor through the hole in the bread bag bottom.
- Wrap blue tape tightly around the bag and sensor tube.
- Bag is clean and dry.
- Hole in the bag bottom is just wide enough for the sensor snout.
- Tape is ready on the bench.
- Make sure that there are no open gaps where gas can escape.
- The bag should hang down freely around the sensor tip.
Careful: Gaps around the tape leak air and spoil oxygen readings. Wrap tape around the junction two full times and press firmly.

Step 2 of 6
Clamp sensor to ring stand
- Attach the utility clamp to the upright rod of the ring stand.
- Clamp the upper teal body of the O2 sensor securely.
- Slide the bread bag upward over the sensor so room air reaches the tip.
- Ring stand base rests on a flat, stable table.
- Clamp screws are tightened so the sensor does not slide.
- Angle the sensor slightly forward so the open bag end is easy to reach.
Careful: Sensor can slip and fall if clamp screws are loose. Tighten the clamp thumbscrew until the sensor is snug. Do not over-tighten.

Step 3 of 6
Perform Trial 1 normal breath hold
- Take one normal deep breath and hold it as your partner taps Collect.
- Hold your breath as long as possible, then blow all exhaled air into the bag and twist the bottom shut.
- Keep the bag twisted shut for the full 2 minutes while the sensor records.
- Subject has no respiratory health problems.
- Subject sits down during the entire test.
- Collector is ready to tap Collect the second the breath hold begins.
- The subject sits comfortably and looks away from the screen.
- Pull the bread bag down so it hangs loosely below the sensor.
Careful: Dizziness occurs if you hold your breath when you stand. Subject must remain seated. Stop immediately if you feel faint.

Step 4 of 6
Examine Trial 1 and ventilate bag
- Untwist the bread bag and pull it up over the sensor when 120 seconds finish.
- Tap the graph to find how long you held your breath before oxygen dropped.
- Record the maximum oxygen (start) and minimum oxygen (end) in your data table.
- Data collection has fully stopped at 120 s.
- Bag is opened to let stale breath escape.
- Allow fresh room air to circulate around the sensor snout.
Careful: If stale breath stays around the sensor, the sensor cannot return to room air level. Flap the bag gently in room air until the sensor reading climbs back near 20.5%.

Step 5 of 6
Perform Trial 2 rapid breathing hold
- Take 10 quick, deep breaths. Forcefully push out all air after each breath.
- On the 11th breath, take a deep breath and hold it as your partner taps Collect.
- Hold your breath as long as possible. Blow all air into the bag. Twist the bag shut. Record data for the next 2 minutes.
- Subject is seated stably in a chair.
- The sensor reading is back above 20% in room air.
- An adult supervisor watches the trial.
- Pull the bread bag back down over the sensor so it hangs open.
Careful: Hyperventilation can cause lightheadedness or a slight tingle in the fingers. Take exactly 10 breaths, no more. If you feel dizzy at any point, stop and breathe normally.
1 more step, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 10, Science, chapter 5: Life Processes
Versions and what each needs
- What makes you need to breathe? (Agricultural Science)
Agricultural Science, 45 min, Based on a Vernier lab
Needs: Go Direct O2 Gas Sensor - What makes you need to breathe? (Biology)
Biology with Vernier, 45 min, Based on a Vernier lab
Needs: Go Direct O2 Gas Sensor
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.