Experiments › Environmental Science & Physics
Where does bulb energy go?
Energy Conversion
A guided experiment in the Stemious app: students read it first, run it at the bench with the sensors listed below, and their data and conclusions are saved to their record. The first steps are below in View mode; the full lab is in the app.
Try it in View mode
Alpha: being verified by teachersThis is how the lab opens in the Stemious app: the first 5 of its 7 steps. To run it with the sensors, record data and take the quiz, students use the app.

Wonder
Why does an old-fashioned reading lamp feel like a miniature room heater?
Show the answer
Incandescent bulbs turn only a tiny fraction of electrical power into light. Most of that energy escapes as scorching heat. Today you will measure both light and heat to uncover the hidden waste.

Introduction
Where Does Bulb Energy Go?
When you flip on a desk lamp, electrical energy rushes through the wires. You want that electricity to produce bright light so you can read. But if you hold your hand near the bulb, you immediately feel intense warmth. Traditional incandescent bulbs convert electrical power into two different forms: light and thermal energy. In this investigation, you will test bulbs of different wattages inside a sealed testing box. Using wireless sensors, you will measure exactly how much light each bulb delivers and see how much energy is turned into heat.
Driving question: Why do traditional light bulbs get so hot, and how much energy actually becomes light?
What you will learn
Today you will find out
- I can explain how a light bulb changes electrical energy into light and heat.
- I can measure light levels in lux for bulbs with different wattages.
- I can relate bulb wattage to the amount of heat energy released.
- I can safely collect light data while keeping proper distance from hot bulbs.
- I can explain why energy-efficient bulbs save money and conserve natural resources.
Why it matters: Lighting accounts for nearly ten percent of home electricity use. Choosing efficient lighting saves money and cuts power plant emissions.
Safety first
Scientist Rules for Today
- Incandescent bulbs reach extreme temperatures seconds after you turn them on. Never touch a hot bulb.
- Purple gloves = teacher does it. Blue gloves = you do it.
- Make sure that only an adult replaces or moves light bulbs with heat-resistant gloves.
- Always allow bulbs to cool for at least two minutes before you replace them.
- Keep liquids far away from the electrical lamp and cords to avoid shock hazards.
- Keep the cardboard box flaps flat and stable on the table so the lamp cannot tip over.
What you need
- Go Direct Light and Color Sensor1 per group
- Go Direct Temperature Probe1 per group
- Tablet running Graphical Analysis1 per group
- cardboard box1 large box (approx. 50 x 30 x 30 cm)
- desk lamp with light bulb1 clamp-on lamp fixture with cord · teacher
- ring stand with clamp2 stands with 2 utility clamps
- 60 W, 75 W, and 100 W bulbs1 set of 3 incandescent bulbs
- ruler1 (30 cm or 50 cm)
- protective lab gloves1 pair heat-resistant gloves + student gloves · teacher

Step 1 of 7 Teacher does this
Set up the lamp inside the testing box
- Position one ring stand inside the box near the left side.
- Use a utility clamp to hold the lamp fixture. Point the fixture horizontally across the box.
- Have an adult screw the 60 W incandescent bulb into the lamp socket.
- The lamp cord is completely unplugged from wall power.
- The ring stand base sits flat and cannot tip over inside the box.
- The utility clamp is tightened firmly around the lamp socket.
- The cardboard box is placed flat on the lab bench with its top flaps open.
Careful: The lamp could slip and crack the glass bulb against the stand base. Support the lamp body with your hand. Tighten the clamp thumbscrew securely.

Step 2 of 7
Align the light sensor outside the box
- Place the second ring stand outside the box, right next to the circular port hole.
- Clamp the Go Direct Light and Color Sensor horizontally. Point the sensor straight through the hole.
- Use a ruler to make sure that the sensor tip is exactly 30 cm from the bulb centre.
- The sensor points directly through the hole. The sensor does not touch the cardboard edges.
- The distance ruler measures exactly 30 cm between bulb and sensor tip.
- The sensor dome points straight at the bulb filament.
Careful: If the sensor is angled away from the bulb, measured light readings will be falsely low. Look straight down the line of sight to confirm the sensor points right at the bulb.

Step 3 of 7
Insert the temperature probe into the testing chamber
- Insert the stainless steel tip of the Go Direct Temperature Probe through a small top slot.
- Position the probe tip about 15 cm above the bulb, suspended in the air inside the box.
- Tape the probe handle or upper shaft gently to the outer flap to hold it securely in place.
- The probe metal shaft hangs freely in the air.
- The probe tip is at least 10 cm away from direct contact with the bulb.
- The probe does not touch the bulb glass or the box walls.
Careful: If you touch the probe directly to the hot glass bulb, you get false high temperatures instead of air temperature. Keep the probe suspended in the air inside the chamber.

Step 4 of 7 Teacher does this
Test the 60 W incandescent bulb
- Have the adult plug in the lamp cord and switch the lamp ON.
- Tap Collect in Graphical Analysis. Record light and temperature for 10 seconds.
- Have the adult switch the lamp OFF immediately, then tap Statistics for mean illumination (in lux) and starting temperature.
- The box flaps are closed securely.
- Hands are dry before the adult plugs in the lamp.
- The tablet is ready to record data.
- The cardboard box flaps are fully closed to block room light.
Careful: Contact with the metal lamp fixture or bulb after it turns on can cause severe burns. Keep hands out of the box interior while the lamp has power. The adult must control the switch.

Step 5 of 7 Teacher does this
Cool down and swap to the 75 W bulb
- Wait at least 2 minutes with the box flaps open for the 60 W bulb to cool.
- Have the adult test the bulb temperature with a heat glove. Have the adult gently unscrew the 60 W bulb.
- Have the adult screw the 75 W incandescent bulb into the socket securely.
- The lamp power switch is turned OFF.
- The power cord is unplugged from the wall outlet.
- The adult wears heat-protective gloves.
- Caution: The bulb glass will be very hot to the touch.
Careful: Bare skin contact with a hot incandescent bulb can cause painful blisters. Unplug the lamp first. Only the adult must handle the hot bulb with heat-protective gloves.
2 more steps, then data, observations, conclusions and a quiz
The full lab is free for teachers. Tell us where to send it and we will share it, along with the app for your students.
Where it fits in the syllabus
- Related Class 7, Science, chapter 3: Electricity: Circuits and their Components
Versions and what each needs
- Where does bulb energy go?
Environmental Science, 60 min, Based on a Vernier lab
Needs: Go Direct Light and Color Sensor, Go Direct Temperature Probe
Vernier instruments are designed for education and are not intended for industrial, medical or commercial testing.